Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 30 for “"microcoils"”.
-
Microcoils manufactured with a wire bonder
Microcoils, and therefore inductors, are crucial passive devices in mobile phones, tablet PCs and GPS devices. Beyond their use in electronics, they are also essential components of microactuators, transformers, and sensors for microscale magnetic resonance imaging. Planar microcoils are fabricated …
-
Investigation of Cryo-Cooled Microcoils for MRI
… the sample being imaged. Micro-scale RF coils (microcoils) can be easily fabricated on chip and placed adjacent to a sample under test. However, the high series resistance of microcoils limits the SNR due to the thermal noise generated in the copper. Cryo-cooling is a potential technique to …
-
Development of self-assembled, rolled-up microcoils for nuclear magnetic resonance spectroscopy
… metal layer transforms into a microcoil. Such microcoils were successfully used for impedimetric measurements, as antennas, and as mentioned for NMR, but their performance in the latter was far from optimal. This thesis focuses on the optimization of rolled-up microcoils (RUMs) for NMR …
-
Microfluidically Cryo-Cooled Planar Coils for Magnetic Resonance Imaging
… in magnetic resonance imaging (MRI). Planar microcoils as receiver probes in MRI systems offer the potential to be configured into array elements for fast imaging as well as to enable the imaging of extremely small objects. Microcoils, however, are thermal noise dominant and suffer limited …
-
Micromagnetic Intracochlear Stimulation: Dual-Axial Microcoil Modeling, Fabrication, and Validation
… to conventional cochlear implant electrodes. Microcoils designed for a cochlear implant array were developed to stimulate neural elements with an improved spatial resolution while operating safely within the constraints of the cochlea. Previous reports show that micromagnetic stimulators …
-
Development of New Micro-coil Technologies for Environmental NMR Research
… µm in diameter). However, the fabrication of microcoils can be an expensive and time consuming process (requiring cleanrooms), which limits the ability of researchers to obtain a variety of microcoils (i.e. each tailored to a specific sample size for optimal analysis). The overall objective of …
-
Planar Coils for NMR Microspectroscopy
Planar microcoils suffer from a reduced sensitivity compared to solenoidal microcoils. However, because of their planar geometry, they can be more easily fabricated and integrated into microanalysis systems through the use of microfabrication techniques. This thesis investigates the feasibility of …
-
High-Resolution Nuclear Magnetic Resonance Microspectroscopy
… application to studying mass-limited samples. Microcoils have been designed for higher magnetic fields (500 MHz) and also now incorporate a lock channel for longer two-dimensional (2D) experiments. Reference deconvolution and wavelet noise reduction have been used to address lineshape …
-
Towards Multiplexed Nuclear Magnetic Resonance for Environmental Analysis
… focus shifted to specialized NMR hardware called microcoils. These devices greatly improve sensitivity for very small samples such as D. magna eggs (<400 μm in diameter) which are critical to aquatic ecosystem health. Cutting-edge complementary metal-oxide-semiconductor (CMOS) technology was used …
-
Enhanced NMR Detection of Mass -Limited Samples With Microcoil Probes: Increasing Sample Throughput and Improved on-Line Coupling to Microscale Separations
… chemical laboratory. The development of microcoils enables NMR analysis of small-volume, mass-limited samples. With their diminutive size, multiple microcoils can be situated in a single NMR probe. Enabling simultaneous spectral acquisition from different analytes, multiple microcoil …
-
Molekularbiologische Charakterisierung der murinen Retina nach bilateraler Okklusion der Arteria carotis communis
… der Retina 6 Wochen nach Implantation der Microcoils, um ein Verständnis über die Pathomechanismen zu erlangen. Methodik: 6 Wochen nach Implantation der Microcoils in C57BL/6J- und MacGreen- Mäusen wurde die Retina entnommen und mittels immunhistochemischer Methoden (HE- Färbung im …
-
Role of TREM2 and neuroinflammation in an experimental model of chronic cerebral hypoperfusion
… studies demonstrated 0.18 mm internal diameter microcoils failed to induce sufficient white matter pathology or neuroinflammatory changes in WT C57BL/6Ntac mice. However, implementation of microcoils with smaller internal diameters (0.16 mm) precipitated robust myelin damage associated with …
-
A 200-MHz fully-differential CMOS front-end with an on-chip inductor for magnetic resonance imaging
… and fabrication of planar spiral inductors (microcoils) that serve as detectors for nuclear magnetic resonance mi- crospectroscopy. The goal of this research was to analyze, design, and test a prototype integrated sensor, which consisted of a similar microcoil detector with analog components …
-
Towards CMOS Nuclear Magnetic Resonance Spectroscopy: Design, Implementation and Experimental Results
… first chip includes number of new vertical microcoils and LNA with 780 pV/Hz at 300 MHz and the second one is a new dual-path NMR receiver.
-
Optimised detectors for integration of NMR with microfluidic devices
… has allowed accurate simulation of these microcoils.
-
Synthesis of dispersible nanostructures using anti-sintering cast materials
… size regimes in the biotemplating of carbonised microcoils using the algae species spirulina.
-
Investigation of interaction of THz-radiation with metallic subwavelength sized structures in far- and near-field
… demonstrates the electromagnetic behaviour of microcoils excited with linearly polarised THz-radiation of different orientation. <br>These microcoils have been produced by automated wire-bonding within a collaboration of the Department of Microsystems Engineering (IMTEK) in Freiburg. <br>The …
-
Characterisation of a mouse model of chronic cerebral hypoperfusion and its application to investigating the impact of hypoperfusion on the development of Alzheimer’s disease
… bilateral carotid artery stenosis (BCAS) using microcoils Hypoperfusion was induced in wild type (WT) mice and the pathological changes examined at one week, two weeks, one month and two months. Hypoperfused animals developed a diffuse and widespread white matter pathology, present from one …
-
The design and fabrication of a magnetically actuated microfluidic dispensing device
… The integrated microdevice includes thick gold microcoils and a fluidic channel containing the paramagnetic beads. The transport and separation of paramagnetic beads was demonstrated and quantified.</p> <p>The fluid displacement technique investigated here is compact and simple to produce and …
Page 1 of 2