Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"microheater"”.

  1. Microheater Stimulation Platform for Neural Cells

    … precision and resolution. This project explores microheaters as a stimulation platform that can be easily integrated with existing biomedical devices. Microheaters produce heat via the Joule heating effect wherein electrical current is run through high resistance materials to output thermal …

    usf Repository record for Microheater Stimulation Platform for Neural Cells (opens in a new tab)

  2. Integrated Microheater Array for Localized Heating of Magnetic Nanoparticles

    … We proposed and demonstrated a miniaturized microheater array utilizing ferromagnetic resonance of the MNP at GHz to enable localized yet accurate temperature manipulation in living cells and tissues.

    rice Repository record for Integrated Microheater Array for Localized Heating of Magnetic Nanoparticles (opens in a new tab)

  3. Microheater Engineering for Phase-Change Material-Based Photonic Devices

    … and electrode design—especially focused on microheater geometry and material selection—as a unifying route to deterministic switching, improved stability, and scalable integration across both free-space and integrated photonic platforms. This thesis demonstrates an ultrathin, optically …

    maryland Repository record for Microheater Engineering for Phase-Change Material-Based Photonic Devices (opens in a new tab)

  4. Nucleate Pool Boiling Characteristics From a Horizontal Microheater Array

    Pool boiling heat transfer measurements from different heater sizes and shapes were obtained in low-g (0.01 g) and high-g (1.7 g) aboard the NASA operated KC-135 aircraft. Boiling on 4 square heater arrays of different size (0.65 mm2, 2.62 mm2, 7.29 mm2, 49 mm2) was investigated. The heater arrays …

    maryland Repository record for Nucleate Pool Boiling Characteristics From a Horizontal Microheater Array (opens in a new tab)

  5. Microheater Array Powder Sintering (MAPS) for Printing Flexible Electronics

    Microheater array powder sintering (MAPS) is a novel additive manufacturing process that uses an array of microheaters to selectively sinter powder particles. MAPS shows great promise as a new method of printing flexible electronics by enabling digital curing of conductive inks on a variety of …

    arkansas Repository record for Microheater Array Powder Sintering (MAPS) for Printing Flexible Electronics (opens in a new tab)

  6. Selective Resistive Sintering: A Novel Additive Manufacturing Process

    … resistive sintering (SRS), uses an array of microheaters to pattern heat for selectively sintering materials. Using microheaters offers significant power savings, significantly reduced overhead cost, and increased printing speed scalability. The objective of this thesis is to obtain a proof …

    arkansas Repository record for Selective Resistive Sintering: A Novel Additive Manufacturing Process (opens in a new tab)

  7. A MICROFLUIDICS APPROACH TOWARDS THE INVESTIGATION OF FREE HEME EFFECTS ON SICKLE CELL HEMOGLOBIN POLYMERIZATION

    … integrated microfluidic device with a localized microheater for the study of HbS polymerization kinetics. We developed fabrication recipes for both an SU-8 based microchannel and a thin film resistive Cu-Cr microheater. We calibrated the heater with both infrared camera and Peltier element and …

    houston Repository record for A MICROFLUIDICS APPROACH TOWARDS THE INVESTIGATION OF FREE HEME EFFECTS ON SICKLE CELL HEMOGLOBIN POLYMERIZATION (opens in a new tab)

  8. Multi-modal, Ultrasensitive Detection of Trace Explosives Using MEMS Devices

    … has been realized with a microthermometer/microheater device using a widely tunable quantum cascade laser. A microthermometer/microheater device responds to the heat generated by non-radiative decay process when the adsorbed explosive molecules are resonantly excited with IR light. …

    calgary Repository record for Multi-modal, Ultrasensitive Detection of Trace Explosives Using MEMS Devices (opens in a new tab)

  9. SELF-HEALING RADIATION-DAMAGED ELECTRONICS VIA INTEGRATED ON-CHIP MICROHEATERS

    … chip packages. This thesis evaluates embedded microheaters for generating localized thermal conditions relevant to radiation-damage recovery. Experimental characterization included microheater voltage and current measurements, forward-looking infrared thermography surface temperatures, and …

    nps Repository record for SELF-HEALING RADIATION-DAMAGED ELECTRONICS VIA INTEGRATED ON-CHIP MICROHEATERS (opens in a new tab)

  10. ANALYSIS OF ANNEALING AS A METHOD TO RECOVER RADIATION-DAMAGED ELECTRONICS

    … radiation damage, MOSFETs can be annealed with a microheater. To simulate the effects of space radiation and microheater annealing, MOSFETs were exposed to a Co-60 radiation source and subsequently annealed on a hot plate. Individual MOSFET performance was measured by characteristic curves, with …

    nps Repository record for ANALYSIS OF ANNEALING AS A METHOD TO RECOVER RADIATION-DAMAGED ELECTRONICS (opens in a new tab)

  11. Micropatterned Heater for Multiplexed Nanoplasmonic Sensing

    … This is possible through the use of a microheater localised on the sensor, which trough Joule heating can make it possible to manage the sensor’s temperature with high accuracy. However, the microheater’s design can determine both energy efficiency and the sensing properties of the …

    chalmers Repository record for Micropatterned Heater for Multiplexed Nanoplasmonic Sensing (opens in a new tab)

  12. Novel Methods in Ball Bond Reliability Using In-Situ Sensing and On-Chip Microheaters

    … to be heated externally or containing on-chip microheaters to heat only the ball bond under test, and not the rest of the microchip or surrounding I/O pads. Of the five chip designs, sample chips were produced by an external company. Experimental studies were then carried out with two of these …

    waterloo Repository record for Novel Methods in Ball Bond Reliability Using In-Situ Sensing and On-Chip Microheaters (opens in a new tab)

  13. Development of a disposable and easy-to-fabricate PCR microfluidic device for DNA amplification

    … device comprises a micromixer, reaction well, microheater, and temperature control system. Several methods have been implemented to reduce the chance of sample-to-sample cross-contamination. The designed control system is able to perform PCR at any temperature inside the ordinary working range …

    uvic Repository record for Development of a disposable and easy-to-fabricate PCR microfluidic device for DNA amplification (opens in a new tab)

  14. MICROSCALE HEAT TRANSFER MEASUREMENTS DURING SUBCOOLED POOL BOILING OF PENTANE: EFFECT OF FLUID PROPERTIES AND BUBBLE DYNAMICS

    … were made in earth gravity using a 2.7 2.7 mm2 microheater array during subcooled pool boiling of pentane. The microheater array consists of 96 independent heater elements that were maintained at an isothermal boundary condition using control circuitry. Experiments were made to investigate the …

    maryland Repository record for MICROSCALE HEAT TRANSFER MEASUREMENTS DURING SUBCOOLED POOL BOILING OF PENTANE: EFFECT OF FLUID PROPERTIES AND BUBBLE DYNAMICS (opens in a new tab)

  15. A microfabricated microconcentrator for sensors and chromatography

    … standard photolithographic processes. First, a microheater embedded in silicon wafer was fabricated. The channels were lined with a conductive layer by sputtering metal film through which an electric current could be passed causing Ohmic heating. The preconcentration was done on thin-film …

    njit Repository record for A microfabricated microconcentrator for sensors and chromatography (opens in a new tab)

  16. Fabrication, Characterization, and Transport Analysis of Silicon-Based Microsystems: Micro Fuel Cells and Micro Gas Perconcentrators

    … while the power and energy required to run a microheater, a key component of the muGPC, were kept small. Another unique feature of the muGPC is the use of an array of microposts coated with thin metal-organic framework adsorbents permitting a small pressure drop across the chamber while …

    uiuc Repository record for Fabrication, Characterization, and Transport Analysis of Silicon-Based Microsystems: Micro Fuel Cells and Micro Gas Perconcentrators (opens in a new tab)

  17. Microfluidic flow rate sensing and control : from portable systems to chip-scale implementations

    … architecture consists of a titanium-tungsten microheater placed under the fluidic channel with two silicon photonic microring resonators placed equidistantly upstream and downstream from the microheater. The proposed design is compact, inexpensive, portable to any photonic foundry process, …

    ubc Repository record for Microfluidic flow rate sensing and control : from portable systems to chip-scale implementations (opens in a new tab) Download PDF for Microfluidic flow rate sensing and control : from portable systems to chip-scale implementations (opens in a new tab)

  18. DESIGN, MICROFABRICATION AND CHARACTERIZATION OF VIBRATING MESH ATOMIZER FOR VISCOUS FLUIDS

    … The enhanced MEMS vibrating mesh atomizer with microheater can operate with viscosities up to 28cP, which is nine times more than the threshold of 3cPs for the independent device. The innovative integrated atomizer device enables new applications in several sectors.

    unm Repository record for DESIGN, MICROFABRICATION AND CHARACTERIZATION OF VIBRATING MESH ATOMIZER FOR VISCOUS FLUIDS (opens in a new tab)

  19. Thermoluminescent Microparticles used as Harsh Environment Temperature Sensors Characterized using MEMS Devices

    … reduce thermal emission. The first method uses a microheater with the metal heating element placed around the perimeter and an aperture placed over the center where a thermoluminescent microparticle is placed blocking thermal emission from the heating element but allowing the light from the …

    umn Repository record for Thermoluminescent Microparticles used as Harsh Environment Temperature Sensors Characterized using MEMS Devices (opens in a new tab)

  20. Rapid Prototyping Technologies for Processing of Nanomaterials with Applications to Microfluidics and Nanoelectronics

    … in fabrication and electronics, a thin film microheater was developed and applied to genetic amplification using the polymerase chain reaction in a manner compatible with point-of-care settings. Subsequently these skills were applied to the processing and characterization of molybdenum …

    waterloo Repository record for Rapid Prototyping Technologies for Processing of Nanomaterials with Applications to Microfluidics and Nanoelectronics (opens in a new tab)

Page 1 of 2