Showing 1 to 20 of 92 for “"micromotion"”.

  1. Micromotion in Trapped Atom-ion Systems

    … This is equivalent to studying the effect of the micromotion since this motion must be neglected for the trapped ion to be considered as a harmonic oscillator. By applying the transformation of Cook \emph{et al.} we find that the micromotion can be represented by two periodically oscillating …

    nus Repository record for Micromotion in Trapped Atom-ion Systems (opens in a new tab) Download file for Micromotion in Trapped Atom-ion Systems (opens in a new tab)

  2. Glenoid Baseplate Micromotion in Reverse Total Shoulder Arthroplasty

    Each year approximately 40,000 reverse total shoulder arthroplasties (RTSA) are performed in the United States. This value is increasing annually due to the aging population and increasing indications for the procedure. The most common indication for RTSA is an irreparable rotator cuff where …

    clemson Repository record for Glenoid Baseplate Micromotion in Reverse Total Shoulder Arthroplasty (opens in a new tab)

  3. Cementless Tibial Base Micromotion During Activities of Daily Living

    … activities of daily living generate tibial micromotion yields insight into surgical technique considerations, and rehabilitation strategies post-operatively. ASTM F3141-15, which specifies knee flexion, Internal-External moment, Medial-Lateral, Anterior-Posterior and Superior-Inferior forces …

    denver Repository record for Cementless Tibial Base Micromotion During Activities of Daily Living (opens in a new tab)

  4. Probing Micromotion in a Multi-Segmented Blade-Style Ion Trap

    … electronics control and ion heating caused by micromotion. Blade-style traps are traditionally hand assembled, and therefore are prone to misalignment, leading to increased levels of micromotion. This limitation causes many adverse effects, all negatively contributing to the quality of the …

    waterloo Repository record for Probing Micromotion in a Multi-Segmented Blade-Style Ion Trap (opens in a new tab)

  5. Fast entangling gates enabled by micromotion in trapped-ion quantum processors

    … design has historically neglected the RF-driven micromotion intrinsically experienced by trapped ions. While this is appropriate for few-ion systems, implementing fast gates in scalable QC architectures will require that micromotion is incorporated into fast gate design. This thesis accordingly …

    anu Repository record for Fast entangling gates enabled by micromotion in trapped-ion quantum processors (opens in a new tab)

  6. Wear, Corrosion, And Micromotion In Retrieval And Autopsy Components Of Tkr

    … the relationships of wear, corrosion, and micromotion as it relates to aseptic loosening in TKR. 17 TKR devices harvested at revision surgeries and 6 necropsy devices available through UAB’s retrieval program were scored for wear and inflammatory cell-induced corrosion (ICIC). All devices …

    uab Repository record for Wear, Corrosion, And Micromotion In Retrieval And Autopsy Components Of Tkr (opens in a new tab)

  7. Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns

    … The objective of this study was to compare micromotion and kinematic patterns of two TAA designs. Methods: A mechanical simulator was designed to apply compressive loads and bending moments to human cadaveric ankles, intact and replaced. It induced a maximal range of motion in the ankle …

    ubc Repository record for Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns (opens in a new tab) Download PDF for Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns (opens in a new tab)

  8. Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components

    … interface. To promote bone ingrowth, low micromotion between the bone and implant of 20 µm to 50 µm is required. Due to the lack of standard micromotion tests for TAA tibial components, the current study aimed to develop a mechanical test to measure the maximum micromotion at the bone …

    queens Repository record for Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components (opens in a new tab)

  9. Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee

    … of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of …

    denver Repository record for Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee (opens in a new tab)

  10. Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty

    … implant configurations that may decrease micromotion and reduce the risk of loosening. Delta XTEND™ baseplates (DePuy Synthes) were implanted into Sawbones™ polyurethane foam blocks (N = 40) and varied in terms of their method of central fixation (screw vs. peg), central length (13.5 vs. …

    queens Repository record for Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty (opens in a new tab)

  11. Examination of Micromotion-Induced Transient Effects of Brain Tissue Interfaced with A Neural Probe

    … period in vivo, which could be related to micromotion-related strain between the probe and surrounding tissue. A series of finite element analyses were conducted using the nonlinear transient dynamic code LSDYNA (LSTC, Livermore, CA) to study the strain induced within the brain in an area …

    odu Repository record for Examination of Micromotion-Induced Transient Effects of Brain Tissue Interfaced with A Neural Probe (opens in a new tab)

  12. Vacuum assembly, atomic source development, and micromotion studies for a trapped Ba+ based quantum processor

    … ion trap systems. Finally, excess micromotion, caused by stray electric fields in RF traps, can lead to undesirable effects such as heating and frequency modulation of atomic transitions. This work evaluates the micromotion compensation capabilities of the Phoenix ion trap used in …

    waterloo Repository record for Vacuum assembly, atomic source development, and micromotion studies for a trapped Ba+ based quantum processor (opens in a new tab)

  13. Trapping and cooling two-dimensional crystals of barium ions

    … of 2D crystals. Ions in RF traps are subject to micromotion, a time-dependent driven motion caused by the RF fields themselves. This micromotion leads to Doppler shifts in laser-ion interactions. Laser cooling of 2D crystals can become increasingly difficult as crystals get bigger and are …

    washington Repository record for Trapping and cooling two-dimensional crystals of barium ions (opens in a new tab)

  14. Validation and Analysis of Model-Predicted Patellar Implant-Synthetic Bone Relative Motion in Cementless Total Knee Replacement During a Single-Leg Lunge

    … however, few cementless patellar implant micromotion tests have been developed. Previous studies were all focused on qualifying tibial micromotion, experimentally measuring relative motion between the tray and bone or computationally predicting micromotion at the tibial tray-bone interface …

    denver Repository record for Validation and Analysis of Model-Predicted Patellar Implant-Synthetic Bone Relative Motion in Cementless Total Knee Replacement During a Single-Leg Lunge (opens in a new tab)

  15. Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion

    Introduction: Short-stem total hip arthroplasty is a treatment method for hip osteoarthritis, but long-term complications such as stress shielding and aseptic loosening can lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective at reducing …

    greece Repository record for Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion (opens in a new tab)

  16. Tibial Strains and Tray-Bone Micromotions After Total Knee Arthroplasty: Computational Studies Evaluating the Tibial Fixation

    … to bony ingrowth onto the porous surface, as the micromotion magnitudes exceeding 150 μm may inhibit bone formations and cause implant loosening. However, the critical parameters influencing SED distributions and tray-bone micromotion are not fully understood. Finite element models have been …

    denver Repository record for Tibial Strains and Tray-Bone Micromotions After Total Knee Arthroplasty: Computational Studies Evaluating the Tibial Fixation (opens in a new tab)

  17. Finite Element Analysis Of Post Vs Threaded-Post Glenoid Baseplates In Reverse Total Shoulder Arthroplasty: A Comparative Study

    … whether threaded central fixation improves micromotion and stress distribution. A finite element model of a left scapula with a commercially available rTSA system was created; the two designs differed only by the central post (standard press‑fit versus threaded). A 756 N physiological load …

    uab Repository record for Finite Element Analysis Of Post Vs Threaded-Post Glenoid Baseplates In Reverse Total Shoulder Arthroplasty: A Comparative Study (opens in a new tab)

  18. Linear Paul trap design for high-fidelity, scalable quantum information processing

    … fidelity of Bell state preparation; a high axial micromotion amplitude, which limits the fidelity of operations on linear ion crystals; and a small numerical aperture in the imaging system, which restricts the collection efficiency and thus the performance of remote entanglement experiments.</p> …

    oxford Repository record for Linear Paul trap design for high-fidelity, scalable quantum information processing (opens in a new tab)

  19. A Biomechanical Comparison Of Varying Peg Angles On Glenoid Implant Stability For Anatomic Total Shoulder Arthroplasty

    … The purpose of this study was to quantify the micromotion of Catalyst OrthoScience’s novel glenoid implant design with varying peg angles of 0-, 8.25-, and 17.5- degrees. The glenoid implants were secured in bone substitute with polymethylmethacrylate (PMMA) bone cement and then cyclically …

    uab Repository record for A Biomechanical Comparison Of Varying Peg Angles On Glenoid Implant Stability For Anatomic Total Shoulder Arthroplasty (opens in a new tab)