  1. A Microfluidic Channel for Detecting Respiratory Pathogens in Young Children

    … respiratory pathogen among young children. Micropillar array electrodes were developed on the surface of the working electrode to enhance surface area which leads to increase the number of antibodies and the number of target analytes that are adsorbed on the surface. Hence, using micropillar …

    bucknell Repository record for A Microfluidic Channel for Detecting Respiratory Pathogens in Young Children (opens in a new tab)

  2. Modeling Droplet Impingement Dynamics on Micropillar-Arrayed Viscoelastic Substrates Through Microgeometry-Free and Multiscale Methods

    The droplet impact dynamics on micropillar-arrayed viscoelastic substrates has been thoroughly investigated by two distinct modeling methods, i.e., microgeometry-free and multiscale modeling methods. The viscoelasticity of the micropillar-arrayed substrate is characterized by a five-parameter …

    vt Repository record for Modeling Droplet Impingement Dynamics on Micropillar-Arrayed Viscoelastic Substrates Through Microgeometry-Free and Multiscale Methods (opens in a new tab)

  3. Design and Optimization of an Array of Hollow Micropillar Structures for Enhanced Evaporative Cooling

    … limits. In this study, we create a patterned array of micropillars with droplets pinned on top, where the shape of the micropillars constrains the shape of the droplets. Using pattern simplification and the Particle Swarm Optimization algorithm, we find an optimized micropillar array structure …

    wustl Repository record for Design and Optimization of an Array of Hollow Micropillar Structures for Enhanced Evaporative Cooling (opens in a new tab)

  4. Single and Two-Phase Convection in Flexible PDMS Microchannels with Micropillar Arrays

    … (PDMS) microchannels with three different micropillar array assemblies ranging from a porosity of 0.8 to 0.91 are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for flow rates ranging from …

    gatech Repository record for Single and Two-Phase Convection in Flexible PDMS Microchannels with Micropillar Arrays (opens in a new tab)

  5. Study and development of micro nano structured photonic surfaces with alternative nanomanufacturing techniques

    … nm) and infrared (7–14 μm) ranges identify one micropillar array and the micro pyramidal array as the most promising, while the selected micropillar array was further evaluated through cooling-power calculations and outdoor temperature measurements exhibiting average temperature drops of 3℃ …

    greece Repository record for Study and development of micro nano structured photonic surfaces with alternative nanomanufacturing techniques (opens in a new tab)

  6. Novel Drop Impact Configurations on Microstructured Surfaces: Non-Newtonian Fluids and Structure Gradients

    … retraction. This Thesis focuses on the effect of micropillar array designs on the droplet impact process for a range of fluids, including non-Newtonian carbopol solutions. The final part of the Thesis is concerned with drop impacts on gradient surface groove patterns. The experiments with square …

    auckland-ms Repository record for Novel Drop Impact Configurations on Microstructured Surfaces: Non-Newtonian Fluids and Structure Gradients (opens in a new tab)

  7. III-Nitride Nanowire Deep-Ultraviolet Light Emitting Diodes

    … of LEDs. An alternative to mesas is to use arrays of closely spaced nano- or micro-structures connected in parallel, which have been shown both experimentally and by simulations to have significantly enhanced light extraction efficiency. In this work, the feasibility of using plasma etched …

    rit Repository record for III-Nitride Nanowire Deep-Ultraviolet Light Emitting Diodes (opens in a new tab)

  8. Understanding the Effects of Surface Texturing on the Heat Transfer Characteristics of Spray Cooling

    … de-ionized water on silicon substrates with micropillar arrays. The pillar height, the pillar diameter, and the pillar spacing of the micropillar array were varied from 5 to 50 μm while keeping the porosity constant at 0.75. An air-assisted nozzle was used to create a liquid spray with a …

    umn Repository record for Understanding the Effects of Surface Texturing on the Heat Transfer Characteristics of Spray Cooling (opens in a new tab)

  9. Bioadhesion at two scales : a self-adhesion criterion for slanted micropillars and the effects of ATP depletion on the energetics of cell contraction

    … of varying chemistry. This is achieved through arrays of fibrils or micropillars found at the tips of these animals’ appendages. Synthetic mimics inspired by the design of these natural systems are actively developed, studied, and used in applications not limited to adhesion. A common limitation …

    ubc Repository record for Bioadhesion at two scales : a self-adhesion criterion for slanted micropillars and the effects of ATP depletion on the energetics of cell contraction (opens in a new tab) Download PDF for Bioadhesion at two scales : a self-adhesion criterion for slanted micropillars and the effects of ATP depletion on the energetics of cell contraction (opens in a new tab)

  10. Cellular phenotype characterisation in different variants of visceral myopathy

    … when traction forces are measured using the micropillar array platform as it provides a robust method which has the potential to be used for therapeutic purposes.

    glasgow Repository record for Cellular phenotype characterisation in different variants of visceral myopathy (opens in a new tab) Download PDF for Cellular phenotype characterisation in different variants of visceral myopathy (opens in a new tab)

  11. Ciliary micropillar fluidic chip capture exosomes for drug resistant cells’ response to nanoparticle therapy test

    … this dissertation, an exosome capturing ciliary micropillar array microfluidics is introduced and applied to evaluate the response of resistant cancer cells under nanoparticle encapsulated chemotherapy. Cancer cells are able to develop different mechanisms to resist therapeutic treatment, …

    texas Repository record for Ciliary micropillar fluidic chip capture exosomes for drug resistant cells’ response to nanoparticle therapy test (opens in a new tab)

  12. Novel breath collection techniques for detection of COVID-19.

    … gradients of several new designs with reduced micropillar array width. From simulation, 3 new designs were fabricated (3LN) and evaluated in terms of pressure drop and Capture Efficiency (CE). A new design was found that performed similarly to the base design but with a smaller footprint. …

    louisville Repository record for Novel breath collection techniques for detection of COVID-19. (opens in a new tab)

  13. Developing microfluidic systems to resolve longstanding hematological questions

    … I found that the physical presence of a micropillar array creates a shear microgradient that leads to the localized adherence and aggregation of platelets that propagates to stem blood flow in the absence of exogenous agonists. Furthermore, I showed RBC fragmentation (schistocyte …

    gatech Repository record for Developing microfluidic systems to resolve longstanding hematological questions (opens in a new tab)

  14. Enhancing the cooling capacity of heat pipes : wicking in micropillar arrays and electrowetting-based droplet pumping

    … the two are inseparable and inversely related. Micropillar arrays are wicking materials where the distances between pillars are independent and variable, which could lead to a decoupled capillary pressure and permeability. The first half of this dissertation work designs, optimizes, …

    texas Repository record for Enhancing the cooling capacity of heat pipes : wicking in micropillar arrays and electrowetting-based droplet pumping (opens in a new tab)

  15. Micro-pillared interfaces for enhanced electrochemical biosensing

    Significant advancements in electrochemical sensing techniques have opened up vast possibilities in Lab-On-Chip (LOC) applications, showcasing potential applications in health and environmental monitoring. The advantages include relatively quick and easy analysis procedures, miniaturization, and …

    adelaide Repository record for Micro-pillared interfaces for enhanced electrochemical biosensing (opens in a new tab)

  16. Quantifying Fibronectin Mechanical Properties using Antibody-Mediated Optical Tweezing (AMOT)

    … cell-assembled FN fibrils suspended between micropillar arrays (MPA) in a unique technique described here as Antibody-Mediated Optical Tweezing (AMOT). At the conclusion of the project, constitutive modeling of the elastic and viscoelastic parameters FN fibrils will be elucidated. These …

    vcu Repository record for Quantifying Fibronectin Mechanical Properties using Antibody-Mediated Optical Tweezing (AMOT) (opens in a new tab)

  17. HIGH-THROUGHPUT APTAMER DISCOVERY AND APTAMER INTEGRATION INTO MICROFLUIDIC DEVICES FOR RARE CELL ANALYSIS

    … and their genomic DNA (gDNA) is isolated using a micropillar array. The long strands of gDNA are physically entangled within the array, and remain in the microchannel even under flow. With this device, we have demonstrated the successful capture of human cervical and ovarian cancer cells. In …

    cornell Repository record for HIGH-THROUGHPUT APTAMER DISCOVERY AND APTAMER INTEGRATION INTO MICROFLUIDIC DEVICES FOR RARE CELL ANALYSIS (opens in a new tab)

  18. Engineering approaches to study lung mechanobiology

    Engineering tools and techniques greatly expand the scope of biological studies, permitting investigation of the interplay between mechanical forces, and cell and tissue biology, and also enabling in vitro replication of the physiological environment. This dissertation describes the development of …

    uiuc Repository record for Engineering approaches to study lung mechanobiology (opens in a new tab)

  19. MICROELECTRODE ARRAY FOR CAPACITIVE TRANSDUCTION OF RETINAL RESPONSES

    … neural activity sensing employ multi-electrode arrays (MEAs) that typically incorporate metal electrodes and measure currents via an electrochemical junction, leading to corrosion and charge transfer across the electrode-tissue interface. High-density neural interface technology will require …

    unm Repository record for MICROELECTRODE ARRAY FOR CAPACITIVE TRANSDUCTION OF RETINAL RESPONSES (opens in a new tab)

  20. Material properties design using simulations and experiments for powder injection molding of lead zirconate titanate (PZT).

    … PIM experiments on designed micro-pillar array geometry were performed using 52 vol. % PZT. Using PIM experiments results as basis, PIM simulations were performed on designed micro-pillar array geometries to understand the effectiveness of PIM simulations with the use of estimated …

    louisville Repository record for Material properties design using simulations and experiments for powder injection molding of lead zirconate titanate (PZT). (opens in a new tab)