Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 62 for “"microscope objective"”.

  1. Design of miniature microscope objective optics for biomedical imaging

    … is on the design and construction of miniature microscope objective optics. The design of miniature microscope objective is both similar and different from conventional microscope objective. The design and construction of two miniature microscope objectives are presented in this dissertation. …

    arizona-thes Repository record for Design of miniature microscope objective optics for biomedical imaging (opens in a new tab)

  2. Design Of A Dynamic Focusing Microscope Objective For Oct Imaging

    … with LC lenses, one involving a reflective microscope objective sub-system, and the other involving an all-refractive immersion microscope objective sub-system are investigated. In order to ensure high resolution imaging, a low coherence broadband source, namely a femtosecond mode-locked Ti: …

    ucf Repository record for Design Of A Dynamic Focusing Microscope Objective For Oct Imaging (opens in a new tab)

  3. Reduction of parasitic diffraction effects in reflective microscope objectives

    … in short focal length systems, such as microscope objective lenses, has until now remained fairly unexplored. This thesis investigates the reduction of intensity spikes in 15X and 40X reflective Schwarzschild microscope objective lenses, where, among different support geometries, the use …

    chalmers Repository record for Reduction of parasitic diffraction effects in reflective microscope objectives (opens in a new tab)

  4. Estimation of Optical Trapping Forces with the Eikonal Function

    … geometrical ray optics,whereby the rays fromthe microscope objective trace straight lines to a single focal point. These rays are refracted by the trapped particle and resultant change in direction of the ray imparts a force due to the conservation of momentum. The model takes no account of the …

    maynooth Download PDF for Estimation of Optical Trapping Forces with the Eikonal Function (opens in a new tab)

  5. Optical Tool Setting and Control for Precision Lathe

    … A collimated blue light source along with a 5X microscope objective were used. Software written in Microsoft Visual Basic 2005 enabled software updates of offsets and tool nose radius. Overall, the system had an average repeatability of 8.2 µm, with an accuracy average of 2.5 µm, providing an …

    ku Repository record for Optical Tool Setting and Control for Precision Lathe (opens in a new tab)

  6. Development of image mapping spectrometer (IMS) for hyperspectral fluorescence microscopy

    … resolution of the IMS depend on the selected microscope objective and for the results presented is 45x45mu 2 and 0.45mum respectively. The system requires no scanning and minimal post data processing. In addition, the reflective nature of the image mapper and use of prisms for spectral …

    rice Repository record for Development of image mapping spectrometer (IMS) for hyperspectral fluorescence microscopy (opens in a new tab)

  7. Waveguide-based TIRFM for Diagnostic Applications

    … collection of fluorescently emitted light with microscope objective. Of the several fluorescence microscopy techniques developed so far, total internal reflection fluorescence microscopy (TIRFM) is one of the most frequently used technique for studying biological interactions at or close to …

    chalmers Repository record for Waveguide-based TIRFM for Diagnostic Applications (opens in a new tab)

  8. Array microscopy technology and its application to digital detection of Mycobacterium tuberculosis

    … Digital array microscopy separates the tasks of microscope operation and pathogen detection and will reduce the specialization needed in order to operate the microscope. Distributing the work and reducing specialization will allow this technology to be deployed at the point of care, taking the …

    rice Repository record for Array microscopy technology and its application to digital detection of Mycobacterium tuberculosis (opens in a new tab)

  9. Selektyvus metalinių mikrodarinių formavimas ant skaidraus dielektriko paviršiaus, panaudojant kombinuotas ultratrumpųjų impulsų lazerines ir chemines technologijas /

    … the dielectric surface: (1) a beam focussed by a microscope objective (0.5 NA) and (2) a Bessel beam generated by an axicon (130° apex angle). In both cases, the laser beam is focussed into a spot with a diameter of several micrometres (in the case of the Bessel beam, this refers to the diameter …

    vilnius Repository record for Selektyvus metalinių mikrodarinių formavimas ant skaidraus dielektriko paviršiaus, panaudojant kombinuotas ultratrumpųjų impulsų lazerines ir chemines technologijas / (opens in a new tab)

  10. IMAGING INTERFEROMETRIC MICROSCOPY TO THE LIMITS OF AVAILABLE FREQUENCY SPACE

    … illumination setup, while using a low NA microscope objective and thus keeping the large working distance, depth of focus and field of view associated with the lower NA. The goal of this dissertation is to reach ultimate resolution limits of non-fluorescent microscopy by using IIM in new …

    unm Repository record for IMAGING INTERFEROMETRIC MICROSCOPY TO THE LIMITS OF AVAILABLE FREQUENCY SPACE (opens in a new tab)

  11. A Method to Dramatically Decrease the Required Depletion Power of STED Super-Resolution Microscopy and High Power Operation of NSOM Probes

    A versatile STED microscope using a supercontinuum light source for selecting various excitation and depletion wavelengths needed for different fluorescent dyes was designed and built. Using a 0.9 NA microscope objective and 100 nm diameter beads, 90 nm de-convoluted lateral super-resolution was …

    tamu Repository record for A Method to Dramatically Decrease the Required Depletion Power of STED Super-Resolution Microscopy and High Power Operation of NSOM Probes (opens in a new tab)

  12. Energy transfer interactions with single molecule phenomena in small clusters of quantum dots

    … from these samples is collected through the microscope objective and spatially filtered using confocal techniques, i.e. spatially filtering the fluorescence with a pinhole. The excitation region can be correlated with a nanoscale topographical image using the light that is backscattered …

    colostate Repository record for Energy transfer interactions with single molecule phenomena in small clusters of quantum dots (opens in a new tab)

  13. Development of a CARS-based multimodal microscopy system for biological tissue imaging

    Modern advanced optical microscopes are important for disease diagnosis and cancer detection since they provide important biochemical information of the biological specimen with subcellular spatial resolution. In my thesis, I have worked on developing a multimodal microscopy. Imaging by coherent …

    ubc Repository record for Development of a CARS-based multimodal microscopy system for biological tissue imaging (opens in a new tab) Download PDF for Development of a CARS-based multimodal microscopy system for biological tissue imaging (opens in a new tab)

  14. Progress towards a quantum simulator with cold atoms

    … and tested. This imaging system uses commercial microscope objectives and has been designed to work with four different microscope objective. Magnification of 5x, 10x 20x and 50x are possible. With the maximum magnification of 50x a resolution of 1.74μm for 780nm was achieved. Also a camera …

    birmingham Download PDF for Progress towards a quantum simulator with cold atoms (opens in a new tab)

  15. Nonlinear and interference techniques for biomedical imaging

    … The realisation of the confocal laser scanning microscope in the 1980s led to major advances in the way optical microscopy is implemented, paving the way for the use of interference techniques such as 4Pi microscopy to increase the optical resolution, and for nonlinear microscopy techniques such …

    strathclyde Repository record for Nonlinear and interference techniques for biomedical imaging (opens in a new tab)

  16. Statinių ir dinaminių fazinių objektų tyrimas panaudojant skaitmeninės holografijos ir modifikuotą Shack-Hartmann metodus /

    … identified that in DH using 20 times enlarging microscope objective, the maximum field of view is 250 μm. The reasons are the zero and first order diffraction maximums that appear in off-axis digital holography. Meanwhile, QWLSI is only limited by the size of diffractive grating and sensor. …

    vilnius Repository record for Statinių ir dinaminių fazinių objektų tyrimas panaudojant skaitmeninės holografijos ir modifikuotą Shack-Hartmann metodus / (opens in a new tab)

  17. Laser Processing of Biological Materials

    … away from a receiving substrate. Using a UV microscope objective, a focused laser pulse is directed at the backside of the ribbon, so that the laser energy first interacts with the matrix at the ribbon/matrix interface. This energy is used to gently desorb the depositing material and matrix …

    gatech Repository record for Laser Processing of Biological Materials (opens in a new tab)

  18. Automation of pollen analysis using a computer microscope : a thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering in Computer Systems Engineering at Massey University

    … use expensive and bulky conventional optical microscopes. Using a solid-state image sensor instead of the human eye removes many of the constraints on the design of an optical microscope. Initially the goal was to develop a single lens microscope for imaging pollen. In-depth investigation and …

    massey Repository record for Automation of pollen analysis using a computer microscope : a thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering in Computer Systems Engineering at Massey University (opens in a new tab)

  19. Selected Topics in Novel Optical Design

    … The optical performance of a motion-free 3D microscope objective based on liquid lens is analyzed in both simulation and experiment set up. In the end, the author will introduce a novel method to correct chromatic aberration of a liquid lens setup, which has been a challenge for previous …

    arizona-thes Repository record for Selected Topics in Novel Optical Design (opens in a new tab)

  20. Characterization of electron propagation via coherent transition radiation in two different conductivity regimes

    … 2ω harmonics of the CTR were imaged using a 10x microscope objective to CCD cameras. The spatial profile and energy emitted at the rear surface were evaluated, showing marked differences between high and low conductive materials. The conductivity is changed through both target temperature and …

    texas Repository record for Characterization of electron propagation via coherent transition radiation in two different conductivity regimes (opens in a new tab)

Page 1 of 4