Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"mini-screws"”.

  1. OPTIMAL SPECIFICATIONS FOR MEASURING BONE-TO-IMPLANT CONTACT OF MINI-SCREWS USING MICRO-CT

    The use of mini-screws (MSs) as temporary anchorage devices (TADs) is becoming more common in orthodontic treatment. With the increased use of TADs and the numerous manufactures producing them, research is needed to aid orthodontists in their selection of MSs. One of the major advantages of using …

    temple Repository record for OPTIMAL SPECIFICATIONS FOR MEASURING BONE-TO-IMPLANT CONTACT OF MINI-SCREWS USING MICRO-CT (opens in a new tab)

  2. Clinical cephalometric study in maxillary incisor retraction using the mini-screws with non-extraction case

    … in non-extraction orthodontic treatment using mini-screws. MATERIALS AND METHODS: This study included 66 patients (mean age 18.07 years) who were diagnosed with skeletal class I malocclusion with mild incisor and lip protrusion. These patients underwent non-extraction orthodontic treatment with …

    ajou Repository record for Clinical cephalometric study in maxillary incisor retraction using the mini-screws with non-extraction case (opens in a new tab) Embargoed until 9999-12-31

  3. COMPARISON OF INSERTION ANGULATIONS MEASURED VIA BONE-TO-IMPLANT CONTACT OF MINI-SCREWS USING MICRO-CT

    Bone-to-implant contact of orthodontic mini-screws has been determined via Micro-CT to be a strong predictor of primary stability. Various insertion angulations, including both 900 and 500, have been reported as ideal for providing optimum primary stability. The aim of this investigation was to …

    temple Repository record for COMPARISON OF INSERTION ANGULATIONS MEASURED VIA BONE-TO-IMPLANT CONTACT OF MINI-SCREWS USING MICRO-CT (opens in a new tab)

  4. Utilização de inteligência artificial para mensurar a espessura do palato em tomografias computadorizadas com vistas à técnica marpe

    Introduction: The mini-screw assisted rapid palatal expansion technique requires the selection of mini-screws with effective lengths that ensure good primary stability through bicorticalization. This necessitates manual measurement of palatal thickness in cone-beam computed tomography (CBCT) scans …

    brazil-ufrn Repository record for Utilização de inteligência artificial para mensurar a espessura do palato em tomografias computadorizadas com vistas à técnica marpe (opens in a new tab)

  5. Comparative analysis of conventional and non-conventional approaches for maxillary molar distalization protocols: a finite element study

    … Pendulum appliance (Pend-X), (3) Infrazygomatic mini-screws with fixed appliances, (4) the Advanced Maxillary Distalization Appliance (AMDA), (5) Miniplate-supported distalization (Bollard Appliance), and (6) the Beneslider appliance. Displacements were analyzed in the sagittal, vertical, and …

    greece Repository record for Comparative analysis of conventional and non-conventional approaches for maxillary molar distalization protocols: a finite element study (opens in a new tab)

  6. Retrospective Evaluation of the Survival Rate of Buccal Mini-implants and the Factors Associated with their Survival

    … study is to evaluate the success rate of common mini-implants used on the buccal side of both the maxilla and mandible for orthodontic purposes. All orthodontic mini-implants placed at the University of Connecticut residency from July of 2013 till April of 2020 by various residents and faculty. …

    uconn-diss Repository record for Retrospective Evaluation of the Survival Rate of Buccal Mini-implants and the Factors Associated with their Survival (opens in a new tab)

  7. Non-Surgical Correction Of Anterior Open Bites Using Temporary Anchorage Devices

    Objective: The purpose of this study is to determine the skeletal, dental and soft tissue effects that occur as a result of maxillary posterior TAD intrusion; to compare treatment outcomes of growing patients to a growing matched control group; and to present a simplified TAD intrusion technique. …

    uab Repository record for Non-Surgical Correction Of Anterior Open Bites Using Temporary Anchorage Devices (opens in a new tab)

  8. Vergleichende Untersuchungen zur Beurteilung des Knochenangebotes im vorderen Gaumen anhand von seitlichen Fernröntgenbildern und dentalen Volumentomogrammen

    … für die Insertion von Gaumenimplantaten oder Minischrauben stehen dem Kieferorthopäden grundsätzlich zwei Bildgebungstechniken zur Verfügung. Das seitliche Fernröntgenbild (FRS) und das dentale Volumentomogramm (DVT). In der Literatur finden sich Verfechter der strahlenärmeren älteren Technik …

    fu-berlin Repository record for Vergleichende Untersuchungen zur Beurteilung des Knochenangebotes im vorderen Gaumen anhand von seitlichen Fernröntgenbildern und dentalen Volumentomogrammen (opens in a new tab)

  9. Palatal rugae: evaluation with a novel method, association of their phenotype with specific genetic variants and the effect of orthodontic extractions

    … planning via the guidance of the insertion of mini-screws palatally, and superimposition. Traditional approaches to rugae evaluation have relied on qualitative indices describing features such as shape, length, and orientation. However, these methods suffer from limited reproducibility and do …

    greece Repository record for Palatal rugae: evaluation with a novel method, association of their phenotype with specific genetic variants and the effect of orthodontic extractions (opens in a new tab)