Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"misoperations"”.

  1. Analysis of power system disturbances due to relay hidden failures

    … abnormal power system states to trigger relay misoperations. Each commonly used relaying scheme in transmission system is examined for any hidden failures that can lead to relay misoperations and multiple power system contingencies. Each hidden failure mode has a region, called region of …

    vt Repository record for Analysis of power system disturbances due to relay hidden failures (opens in a new tab)

  2. Analysis of two-stage shunt capacitor bank protection deficiencies with mitigation suggested

    … a two-stage capacitor bank resulting in misoperations of the bank protection. When the bypass switch is opened a long duration dc offset occurs across all capacitors. This dc causes saturation of the tap point VT resulting in a false differential voltage and misoperation of the …

    utc Repository record for Analysis of two-stage shunt capacitor bank protection deficiencies with mitigation suggested (opens in a new tab)

  3. Advancing Power Equipment and Line Protection with Practical Solutions

    … work describes the detailed analysis of various misoperations of protective relays and the solutions that those analysis led to. The last chapters round out the manuscript with two innovations that the author advanced, and which are now becoming part of the state of the art in generator …

    utk-theses Repository record for Advancing Power Equipment and Line Protection with Practical Solutions (opens in a new tab)

  4. Test Plan for Real-Time Modeling & Simulation of Single Pole Switching Relays

    … (SPS) feature. Single-pole switching can cause misoperations due to fault arc during reclosing of the breakers. Through this investigation, a test procedure appropriate for the testing SPS relays has been developed. The test procedure includes power system modeling for real time simulation, …

    uno Repository record for Test Plan for Real-Time Modeling & Simulation of Single Pole Switching Relays (opens in a new tab)

  5. Dynamic state estimation based transmission line protection

    … functions, and as a result, reduce relay misoperations. The dynamic model of the line is first converted into an equivalent algebraic companion form by quadratic integration. Then three dynamic state estimation algorithms and the protection logic based on the estimation results are …

    gatech Repository record for Dynamic state estimation based transmission line protection (opens in a new tab)

  6. Fault location and analysis in transmission and distribution networks

    … alter fault current levels and result in relay misoperations. Finally, data recorded by IEDs during a fault contain a wealth of information and are prime for use in other applications that improve power system reliability. Based on the above background, the first objective of this dissertation …

    texas Repository record for Fault location and analysis in transmission and distribution networks (opens in a new tab)

  7. Real-time grid topology modeling and optimization for power transmission systems

    … topology changes. These changes can be caused by misoperations of substation protection systems, malicious cyber attacks, or natural disasters. Although strategically altering the grid topology through transmission switching can effectively relieve network congestion and thus has the potential to …

    texas Repository record for Real-time grid topology modeling and optimization for power transmission systems (opens in a new tab)

  8. Addressing the Performance of Distance Relays in Presence of Inverter Based Resources

    … on in-zone faults. The main reasons for these misoperations are the negative sequence current blocking function in inverters and the changed angular relationships between the sequence voltages and currents dictated by the IBR control schemes. This work proposes a solution that uses the method …

    clemson Repository record for Addressing the Performance of Distance Relays in Presence of Inverter Based Resources (opens in a new tab)

  9. Influence of instrument transformers on power system protection

    … inuence of distortions may lead to disastrous misoperations of protective devices. To overcome this problem, a new instrument transformer design has been devised: optical sensing of currents and voltages. In the theory, novel instrument transform- ers promise a distortion-free replication of …

    tamu Repository record for Influence of instrument transformers on power system protection (opens in a new tab)

  10. Modelling the impacts of space weather on UK railway signalling systems

    … it is suggested that a large number of misoperations of both types could occur across each route.

    lancaster Download PDF for Modelling the impacts of space weather on UK railway signalling systems (opens in a new tab)

  11. State estimation-based centralized substation protection scheme

    … cope with new characteristics and avoid relay misoperations because of hidden failures. This dissertation introduces a new dynamic state estimation-based centralized protection scheme (DSEBCPS) at the substation level. This system supplements dynamic state estimation-based protection for …

    gatech Repository record for State estimation-based centralized substation protection scheme (opens in a new tab)

  12. Critical Substation Risk Assessment and Mitigation

    … a cascading model based on protection system misoperations to estimate system risk from loss-of-substation events in order to assess each substation's criticality. A continuation power flow method is utilized for estimating voltage collapse during cascades. Transient stability is included …

    vt Repository record for Critical Substation Risk Assessment and Mitigation (opens in a new tab)

  13. Resilient Monitoring and Robust Control towards Blackout Prevention in Modern Power Grids

    … the most sensitive energy functions during relay misoperations. Such events can be precipitated by zone 3 trips in distance relays due to load encroachment during stressed conditions. These might include a genuine misoperation, a false trip due to cyber-attacks, or a load encroachment, all of …

    ndsu Repository record for Resilient Monitoring and Robust Control towards Blackout Prevention in Modern Power Grids (opens in a new tab)

  14. An indoor pedestrian localisation system with self-calibration capability

    … the technicians get absent-minded in the work, misoperations to start/end of the task for collecting RSS samples on the current RP at wrong time moments, forgetting to notify the system of the fact that the technician has moved on to the next RP, etc., are avoided. The technicians no longer feel …

    whiterose Download PDF for An indoor pedestrian localisation system with self-calibration capability (opens in a new tab)

  15. An indoor pedestrian localisation system with self-calibration capability

    … the technicians get absent-minded in the work, misoperations to start/end of the task for collecting RSS samples on the current RP at wrong time moments, forgetting to notify the system of the fact that the technician has moved on to the next RP, etc., are avoided. The technicians no longer feel …

    whiterose Download PDF for An indoor pedestrian localisation system with self-calibration capability (opens in a new tab)