Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"mixed cellulose ester"”
-
Quantitative detection of rotavirus and enterovirus in raw sewage using reverse transcription droplet digital PCR
… chloride (PEG/NaCl) precipitation and mixed cellulose ester (HA) filter methods for virus recovery." -- Abstract.
-
Evaluation of surface sampling methods for platinum salts
… refinery. Methods: Two types of filters (mixed cellulose ester and polyvinyl chloride) and GhostwipesTM were evaluated and compared in this study. Platinum solution (hexachloroplatinic acid) concentrations of 50, 150 and 300 μg Pt/ml solution were used. The retention efficiency of the …
-
Hydrogen Fluoride Method Development For The OgawaTM Passive Sampling Device
… Field and laboratory trials were conducted. Mixed cellulose ester filters were saturated with 70% TEA and placed in the PSDs. Aermod ISCT3 modeled ambient HF concentrations at Coronet to guide deployment of PSDs at 28 sampling stations, 3 PSDs per station, 500 – 3500 meters from Coronet. …
-
The Relationship Between Molten Iron Chemistry Of A Cupola Furnace And Airborne Contaminants
… the emissions of a cupola furnace using 37 mm mixed cellulose ester (MCE) filter cassettes at an iron foundry. The samples were analyzed for 21 elements and compounds by a commercial laboratory using the modified National Institude for Occupational Safety and Health (NIOSH) Method 7303, most of …
-
Aerosol Samplers Comparison: IOM Dual Sampler (Inhalable & Respirable) vs Conventional Methods for Assessing Welders Exposure to Manganese
… An aluminum cyclone was used with a 25-mm Mixed Cellulose Ester (MCE) filter to sample respirable Mn contaminants. A 25-mm MCE filter was also used to sample total Mn contaminants. All monitoring was performed by area sampling. The aluminum cyclone readings, except one, were consistently …
-
PRACTICALITY OF USING AIR LEAD MEASUREMENTS BY PORTABLE X-RAY FLUOURESCENCE TO MANAGE WORKER PROTECTION PROGRAMS
… samples were collected in 37 mm cassettes on mixed cellulose ester filters over two weeks. Twenty (20) personal and twenty-seven (27) area samples were obtained. Samples collected during week one were analyzed by XRF the following Sunday, when no work was scheduled on EAGLE. Samples obtained …
-
FILTER SAMPLING OF AIRBORNE MICROBIAL AGENTS - EVALUATION OF FILTER MATERIALS FOR PHYSICAL COLLECTION EFFICIENCY, EXTRACTION, AND COMPARISON TO TRADITIONAL BIOAEROSOL SAMPLING
… of Bacillus anthracis. Four filter types (mixed cellulose ester (MCE), two polytetrafluoroethylene (PTFE), and gelatin) in conjunction with Button Inhalable Aerosol samplers were tested using B. atrophaeus, a B. anthracis surrogate. Vortexing with ultrasonic agitation and vortexing with …
-
Electrochemical Composite Membranes based on Intrinsically Conducting Polymers
… membrane. Polyaniline (PANI) was deposited on mixed-cellulose ester (ME) microporous membranes by using various in situ chemical oxidative polymerization techniques. These include solution-phase polymerization, vapour-phase polymerization and diaphragmatic polymerization in a two-compartment …
-
Characterization of microporous membrane filters using scattering techniques
… chord), sample density of MCE (a mixture of nitrocellulose and cellulose acetate with nominal pore sizes from 0.025 to 1.2 µm), PVDF (Polyvinylidene fluoride with nominal pore sizes from 0.1 to 1.2 µm), Nylon (pore size 0.1 µm) and Anopore Whatman (top 0.02 µm bottom 0.2 µm) membranes were …
-
Thermally driven Knudsen gas pump enhanced with a thermoelectric material.
… to slow pumping. The polymer material, made of mixed cellulose ester, has a very low thermal conductivity, which aids in maintaining a higher temperature difference between the ends of a channel to achieve a higher flowrate. The polymer material used is in the form of a nanoporous template which …
-
ADVANCED IMAGING AS A NOVEL APPROACH TO THE CHARACTERIZATION OF MEMBRANES FOR MICROFILTRATION APPLICATIONS
… be approximately 24 microns and 7-8 microns for mixed cellulose ester and polyethersulfone membranes, respectively, making it impossible to image about 70% of the membrane bulk. The development and implementation of my cross-sectional CLSM method enabled the imaging of the entire membrane …
-
Evaluation of exposure to airborne soluble platinum in a precious metal refinery during non–routine operations
… housing reusable 25 mm filter cassettes with mixed cellulose ester (MCE) membrane filters for the collection of inhalable airborne particles. Because both the cassette and the filter were pre- and post-weighed as a single unit, all particles collected (even those against the walls of the …
-
Characterising indoor airborne particulate matter in Sharpeville, Gauteng
… and connected to a 37mm cassette containing Mixed Cellulose Ester (MCE) filters was conducted simultaneous with photometric samplers. Although this was done as a reference method to compensate for overestimation that comes with the laser photometers, a correction factor of 0.715 was adopted …
-
Characterisation of nickel in platinum refining process dust
… filter cassette was installed with 25 mm mixed cellulose ester (MCE) filters, with a pore size of 0.8 μm. Where applicable, MultiDust Foam inserts® (SKC, United Stated of America) were used to determine the respirable fraction. Three IOM samplers were used to determine the inhalable dust …