Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 64 for “"mixing chamber"”.

  1. Experimental characterization of mixing chamber stall in vacuum ejectors

    … which can produce complex flow structures in the mixing chamber as the secondary flow is entrained. One possible cause of poor performance is boundary layer separation from the walls of the mixing chamber, which is referred to as “mixing chamber stall”. In addition to degrading the performance of …

    ubc Repository record for Experimental characterization of mixing chamber stall in vacuum ejectors (opens in a new tab) Download PDF for Experimental characterization of mixing chamber stall in vacuum ejectors (opens in a new tab)

  2. Application of CFD in designing a drug delivery mixing chamber: an experimental and computational study

    … tIk1 spacer volume was used, hence the drug was mixing better than in the original Volumatic /A/ spacer, where about one third of the spacer volume remained completely empty of the drug. The studies carried out so far had shown that the additional increase in drug delivery efficiency in the case …

    greenwich Download PDF for Application of CFD in designing a drug delivery mixing chamber: an experimental and computational study (opens in a new tab)

  3. An analysis of the properties of two-dimensional incompressible fluid flow in the mixing chamber of a constant area ejector

    The properties of an incompressible fluid in the mixing chamber of a constant area cylindrical ejector are analyzed in a two-dimensional form. The flow field for velocity and temperature is assumed to be made up of regions in which uniform flow of the primary and secondary fluids exist, and which …

    nps Repository record for An analysis of the properties of two-dimensional incompressible fluid flow in the mixing chamber of a constant area ejector (opens in a new tab)

  4. Interactions of Confined-Jet Flow Structures with Ejector Entrainment and Compression

    … conducting a parametric study and analyzing the mixing chamber static pressure. Three factors that affect the recirculation eddy were considered: the mixing chamber diameter ratio, the mixing chamber back pressure, and the mass flow of the primary jet. Recirculation eddy structures in the …

    calgary Repository record for Interactions of Confined-Jet Flow Structures with Ejector Entrainment and Compression (opens in a new tab)

  5. Cellulose-Polymer Composites

    … of the composites. Main processes compared were mixing chamber-compression molding, mixing chamber-compression molding followed by calendaring. Composites with up to 60 wt% untreated hammer milled fluffed cellulose fibers processed. Poly (ethylene-co-acrylic acid) (EAA) is a polar polymer and …

    chalmers Repository record for Cellulose-Polymer Composites (opens in a new tab)

  6. CFD SIMULATION AND SHAPE OPTIMIZATION OF SUPERSONIC EJECTORS FOR REFRIGERATION AND DESALINATION APPLICATIONS

    … numerical methods and to optimize the ejector’s mixing chamber wall shape to obtain a maximum entrainment ratio (ER) in order to obtain the highest possible efficiency that can be attained by the ejector. A steam ejector applied in the cooling industry is first studied to determine the most …

    wustl Repository record for CFD SIMULATION AND SHAPE OPTIMIZATION OF SUPERSONIC EJECTORS FOR REFRIGERATION AND DESALINATION APPLICATIONS (opens in a new tab)

  7. Validation of Improved Hardware and Software for Expired Gas Analysis Indirect Calorimetry

    … and RER between the new system and a commercial mixing chamber system (ParvoMedics) for repeated measurements at rest, steady state and non-steady state cycle ergometry exercise. Post acquisition processing involved custom developed software (LabVIEW), where time to gas equilibration within the …

    unm Repository record for Validation of Improved Hardware and Software for Expired Gas Analysis Indirect Calorimetry (opens in a new tab)

  8. DEVELOPING ELECTROOSMOTIC-PUMP-BASED MINIATURIZED DEVICES: TOWARD A LIQUID CHROMATOGRAPHY CARTRIDGE COUPLED WITH MASS SPECTROMETER AND A SUB-PICOLITER PIPETTOR FOR SINGLE CELL SURGERY

    … In the second method (Chapter 3), we added a mixing chamber after the EOP (Figure 3 1). When a high voltage was applied, the EOP withdrew a series of gradient eluents having different elution strengths via a selection valve. The eluents went through the mixing chamber and towards to EOP. Once …

    oklahoma-thes Repository record for DEVELOPING ELECTROOSMOTIC-PUMP-BASED MINIATURIZED DEVICES: TOWARD A LIQUID CHROMATOGRAPHY CARTRIDGE COUPLED WITH MASS SPECTROMETER AND A SUB-PICOLITER PIPETTOR FOR SINGLE CELL SURGERY (opens in a new tab)

  9. Analysis of Flow in a 3D Chamber and a 2D Spray Nozzle to Approximate the Exiting Jet Free Surface

    … of cooling fluids in the 3D "twister-effect" mixing chamber and to approximate the free surface behaviors exiting the 2D spray nozzle. The cone angle and free surface height located at the end of the free surface are two significant factors to determine the spraying area on a heated plane. …

    usf Repository record for Analysis of Flow in a 3D Chamber and a 2D Spray Nozzle to Approximate the Exiting Jet Free Surface (opens in a new tab)

  10. Cooling of electrically insulated high voltage electrodes down to 30 mK

    … insulated. The trap is thermally linked to a mixing chamber of a 3He-4He dilution refrigerator. Two link designs are examined, the Rod design and the Sandwich design. The Rod design electrically connects a single electrode with a heat exchanger, immersed in the helium of the mixing chamber, by …

    qucosa-diss

  11. Planejamento experimental aplicada a um novo separador líquido-líquido utilizado no tratamento de águas residuais contaminadas com petróleo

    … The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil …

    brazil-ufrn Repository record for Planejamento experimental aplicada a um novo separador líquido-líquido utilizado no tratamento de águas residuais contaminadas com petróleo (opens in a new tab)

  12. An investigation of the performance and mixing phenomena associated with a supersonic exhauster interacting with subsonic secondary flow.

    … This thesis is an experimental study of the mixing process that occurs between the two streams in a cylindrical mixing chamber. In addition, a theoretical model of the exhauster performance based on polytropic efficiencies and conservation of momentum was programmed, and the predicted values …

    nps Repository record for An investigation of the performance and mixing phenomena associated with a supersonic exhauster interacting with subsonic secondary flow. (opens in a new tab)

  13. Occlusion of the left atrial appendage using catheter-delivered hydrogels for prevention of thromboembolic phenomena

    … as a more effective method of occluding the chamber. This material would be transported to the LAA in liquid form via a multi-lumen catheter, and then solidify within the chamber to form a solid plug. Previous research has identified a candidate hydrogel, comprised of PEG-tetra-thiol and …

    texas Repository record for Occlusion of the left atrial appendage using catheter-delivered hydrogels for prevention of thromboembolic phenomena (opens in a new tab)

  14. A comparison of solid fuel ramjet flow characteristics and combustion behavior

    … related to near-wall turbulence intensity/mixing and to the amount of fuel reaching the aft mixing chamber.

    nps Repository record for A comparison of solid fuel ramjet flow characteristics and combustion behavior (opens in a new tab)

  15. Investigation on foam stability and foam-conditioned soil properties under pressure in EPB TBM tunneling

    … throughout the residency time (30-90 min) in the mixing chamber. It is very important to understand the fundamentals of foam stability and foam-conditioned soil properties. This thesis examines foam stability under pressure through a novel foam generation – pressure chamber – foam capture testing …

    colo-mines Repository record for Investigation on foam stability and foam-conditioned soil properties under pressure in EPB TBM tunneling (opens in a new tab)

  16. Bio-derived Fuels for Hybrid Rocket Motors

    … in a laboratory scale hybrid rocket combustion chamber located at the University of Tennessee, Knoxville. Pure lard soaked in an open cell sponge matrix and beeswax were both tested using gaseous oxygen as the oxidizer. Given similar testing conditions, these fuels exhibit higher regression …

    ut-knoxville Repository record for Bio-derived Fuels for Hybrid Rocket Motors (opens in a new tab)

  17. Characterization of the Effects of Jet Radial Position on Entrainment Ratio in a Subsonic Ejector

    … loss due to the jet’s interaction with the mixing chamber walls. An experimental campaign was performed to validate the CV analysis. Pressure and entrainment ratios were experimentally determined for an AIS in a concentric alignment. Secondly, entrainment ratios were recorded for changing …

    calgary Repository record for Characterization of the Effects of Jet Radial Position on Entrainment Ratio in a Subsonic Ejector (opens in a new tab)

  18. Improving the Readout of Semiconducting Qubits

    … cooling power, and high signal gain at the mixing chamber stage leading to around a factor of ten speedup in readout time for a similar signal-to-noise ratio. The faster readout time generally increases fidelity, since it is much faster than the T1 time. Two HBT amplification circuits have …

    unm Repository record for Improving the Readout of Semiconducting Qubits (opens in a new tab)

  19. Computer interfaced stopped-flow kinetics

    … method in which two reactants are forced into a mixing chamber and their flow abruptly stopped. The progress of the reaction is monitored at an observation window, a short distance from the chamber along the flow path. Traditionally, data from the stopped-flow has been collected on film from a …

    vt Repository record for Computer interfaced stopped-flow kinetics (opens in a new tab)

Page 1 of 4