Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"model-based calibration"”.
-
Aktive Ausgangsselektion zur modellbasierten Kalibrierung dynamischer Fahrmanöver
Die modellbasierte Kalibrierung dynamischer Fahrmanöver an Prüfständen ermöglicht die systematische Optimierung von Steuergerätedaten über den gesamten Betriebsbereich des Fahrzeugs und begegnet somit der steigenden Komplexität in der Antriebsstrangentwicklung. Dabei werden mehrere empirische …
-
Application of Multidisciplinary Design Optimisation Frameworks for Engine Mapping and Calibration
… emissions legislation, the engine mapping and calibration task of identifying optimal actuator settings is much more difficult. The aim of this research is to evaluate the feasibility and effectiveness of the Multidisciplinary Design Optimisation (MDO) frameworks to optimise the multi-attribute …
-
Calibration of Multiple Non-Gimbal Mounted Camera-Mirror Systems
… adjustment of the sensor’s field of view. The calibration method compensates for misalignments both within individual rigs and between different rigs, and enables all rigs to observe the same 3D point. This thesis project focuses on calibrating a setup consisting of two rigs. Based on a …
-
High performance optical force sensing - design, characterization and integration in robotic minimally invasive surgery
… coupled with co-located digital electronics based on a Field Programmable Gate Array (FPGA) that samples all sensing channels synchronously, enabling very low noise displacement sensing with a resolution of 1.62 nm, low measurement signal latency of 100 μs, high measurement bandwidth of 500 …
-
Diesel combustion control with digital rate shaping
… for triple pilot injection were again tested. Based on the Rate of heat release curve, each parameter, i.e. dwell time, fuel quantities and rail pressures were manually varied. Next, design of experiments (DoE) was set up using ETAS ASCMO. Running the DoE point in single-cylinder test rig, a …
-
High linearity analog and mixed-signal integrated circuit design
… in electrical circuits.;In Chapter 1, a ladder-based transconductance networks has been adopted first time to build a low distortion analog filters for low frequency applications. This new technique eliminated the limitation of the application with the traditional passive resistors for low …