  1. Model-Based Reconstruction Methods for MR Relaxometry

    In this work, a model-based acceleration of parameter mapping (MAP) for the determination of the tissue parameter T1 using magnetic resonance imaging (MRI) is introduced. The iterative reconstruction uses prior knowledge about the relaxation behavior of the longitudinal magnetization after a …

    wurz-thes Repository record for Model-Based Reconstruction Methods for MR Relaxometry (opens in a new tab)

  2. Model-based Reconstruction of Myocardial Perfusion SPECT and PET Images

    … of this research is to develop and evaluate a model-based reconstruction method for emission computed tomography applied to myocardial perfusion imaging to improve perfusion quantification and functional assessment without the presence of anatomical images. The idea is to model the left …

    jhu Repository record for Model-based Reconstruction of Myocardial Perfusion SPECT and PET Images (opens in a new tab)

  3. Bi-convex model based reconstruction methods for magnetic resonance elastography

    … to extend MRE for advanced biomechanical models. However, MRE is limited by its long scanning time, low signal-to-noise ratio, and low resolution. This thesis focuses on iterative model-based reconstruction techniques with structured sparsity for faster MRE acquisition and robust …

    ubc Repository record for Bi-convex model based reconstruction methods for magnetic resonance elastography (opens in a new tab)

  4. Model-based reconstruction for correcting magnetic susceptibility-induced artifacts in magnetic resonance imaging

    … on MR imaging. This dissertation demonstrates, models, and corrects the important effects of the background magnetic field and the corresponding susceptibility-induced magnetic field gradients (SI-MFGs) in MRI. The background SI-MFGs have particularly a strong impact on applications using …

    uiuc Repository record for Model-based reconstruction for correcting magnetic susceptibility-induced artifacts in magnetic resonance imaging (opens in a new tab)

  5. Fast quantitative T1 mapping based on simultaneous-multi-slice acquisitions using spiral gradients and model-based reconstruction algorithms applied to whole head MR imaging at 3 Tesla

    … innovative acquisition scheme with an iterative model-based reconstruction algorithm is proposed. It combines a single-shot inversion recovery (IR) with a non-IR-prepared acquisition without waiting intervals. Shorter acquisition times can be achieved using a single IR preparation combined with …

    wurz-thes Repository record for Fast quantitative T1 mapping based on simultaneous-multi-slice acquisitions using spiral gradients and model-based reconstruction algorithms applied to whole head MR imaging at 3 Tesla (opens in a new tab)

  6. Development and Optimization of Methods for Accelerated Magnetic Resonance Imaging

    … accuracy, using analytical and numerical signal models. A quantitative acquisition to map the transverse relaxation T2 was first accelerated by combining parallel imaging with model-based reconstruction. It was demonstrated that the combination leads to an improved artifact behavior in comparison …

    epfl Repository record for Development and Optimization of Methods for Accelerated Magnetic Resonance Imaging (opens in a new tab)

  7. Reconstruction of wind turbine wake wind fields with long-range LiDAR measurements

    … first two central moments of the wind speed. The model-based reconstruction of 3D1C wake wind fields allows novel observations of the wake dynamics in the horizontal and vertical direction. In an example data set from a numerical LiDAR simulator and a large-eddy simulation, the wake wind field is …

    oldenburg Repository record for Reconstruction of wind turbine wake wind fields with long-range LiDAR measurements (opens in a new tab)

  8. Dynamic speech imaging with low-rank approximation

    … speech imaging. This thesis presents a novel model-based dynamic MR imaging method to capture speech dynamics in high spatiotemporal resolution. Specifically, high spatiotemporal resolution reconstruction from very sparsely sampled data is achieved using the partial separability (PS) model, …

    uiuc Repository record for Dynamic speech imaging with low-rank approximation (opens in a new tab)

  9. Flaw reconstruction in NDE using a limited number of x-ray radiographic projections

    … around the object. This dissertation presents a model based reconstruction technique which requires a small number of x-ray projections from one side of the object under test. The estimation and reconstruction of model parameters rather than the flaw distribution itself requires much less …

    iastate Repository record for Flaw reconstruction in NDE using a limited number of x-ray radiographic projections (opens in a new tab)

  10. DEEP LEARNING METHODS FOR IMPROVING THE PERCEPTUAL QUALITY OF NOISY AND REVERBERANT SPEECH

    … ratios (SNRs).Time-frequency (T-F) masking and model-based separation are two common ways to extract speech in a noisy observation. T-F masking involves the estimation of an oracle mask, which can be accomplished using supervised learning. Deep neural networks (DNN) are well suited for T-F mask …

    ohiolink Repository record for DEEP LEARNING METHODS FOR IMPROVING THE PERCEPTUAL QUALITY OF NOISY AND REVERBERANT SPEECH (opens in a new tab)

  11. Computational Imaging: a Multi-Facet Perspective

    … science and engineering problems by enabling the reconstruction of images from a variety of measurements that are often indirect or non-traditional. This thesis explores numerical methods to efficiently compute operators that appear in CI problems, specifically non-uniform Fast Fourier Transforms …

    epfl Repository record for Computational Imaging: a Multi-Facet Perspective (opens in a new tab)

  12. Estimating the subjective perception of object size and position through brain imaging and psychophysics

    … functional magnetic resonance imaging and a model-based reconstruction technique, the first part of this thesis sets out to test if retinotopic encoding of size percepts can be generalised to apparent position representation and whether neural signatures could be used to predict an …

    ucl Repository record for Estimating the subjective perception of object size and position through brain imaging and psychophysics (opens in a new tab)

  13. On the Foundations of Computation and Sampling for Reconstruction and Approximation

    … Many of them are security sensitive, like image reconstruction and classification in health care or scene detection for self-driving cars. In these cases, it is of utmost importance that we can guarantee that the algorithms work stably and accurately. To ensure this we investigate the foundations …

    cambridge Repository record for On the Foundations of Computation and Sampling for Reconstruction and Approximation (opens in a new tab)

  14. Time-varying source reconstruction

    … should consider a Temporally Adaptive SourcE Reconstruction (TASER) approach to solving the inverse problem. We achieve this by introducing a novel machine learning unsupervised recurrent neural network (RNN) based algorithm. Our model does not make restrictive assumptions about the temporal …

    oxford Repository record for Time-varying source reconstruction (opens in a new tab)

  15. ENHANCING DEEP LEARNING IMAGE RECONSTRUCTION IN BREAST CT WITH TASK-DRIVEN TRAINING AND PHYSICS-INFORMED MODELS

    … CT view angles. However, traditional image reconstruction methods yield noisy, artifacted images in this sparse-view CT setting. This dissertation develops image restoration and reconstruction methods that address these limitations by integrating physics-informed iterative methods with …

    marquette Repository record for ENHANCING DEEP LEARNING IMAGE RECONSTRUCTION IN BREAST CT WITH TASK-DRIVEN TRAINING AND PHYSICS-INFORMED MODELS (opens in a new tab)

  16. Accelerated Quantitative Mapping and Angiography for Cerebral and Cardiovascular Magnetic Resonance Imaging

    … methods, contributes novel fast acquisition and reconstruction techniques, and proposes new ways of analyzing real-time MRI data. First, we aim to determine an advantageous approach for accelerating high spatial resolution 3D cardiac T2 relaxometry data by comparing the performance of different …

    jhu Repository record for Accelerated Quantitative Mapping and Angiography for Cerebral and Cardiovascular Magnetic Resonance Imaging (opens in a new tab)

  17. 4D reconstruction of oncological dynamic PET data

    <p>4D reconstruction of dynamic positron emission tomography (dPET) data suppresses noise in both the reconstructed image sequences and kinetic parameter estimates by fitting smooth temporal functions to the voxel time-activity-curves (TACs) during the reconstruction. Cancer imaging studies often …

    oxford Repository record for 4D reconstruction of oncological dynamic PET data (opens in a new tab)

  18. Action in memory and memory in action: experiments in the encoding and retrieval of spatial representation

    … memory as a substrate for mental simulation or model-based reconstruction of unseen, future or fictional scenes and behaviours.</p> <p>Chapters II-IV (Action in Memory) report the foundational modulation of memory through a manipulation of the alignment between action selections and supervision …

    oxford Repository record for Action in memory and memory in action: experiments in the encoding and retrieval of spatial representation (opens in a new tab)