Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 35 for “"monitor units"”

  1. The Clinical Effect of Changing from a Dose to Water to a Dose to Medium-Based Methodology to Calculate Monitor Units for Electron Beams

    … in a change in clinical practice whereby monitor units (MU) delivered to patients would be calculated in terms of dose to medium (𝐷𝑚), rather than using measured, dose to water (𝐷𝑤)-based MU. Delivering high energy ionising radiation during radiotherapy has inherent risks. Therefore, it is …

    adelaide Repository record for The Clinical Effect of Changing from a Dose to Water to a Dose to Medium-Based Methodology to Calculate Monitor Units for Electron Beams (opens in a new tab)

  2. Characterizing ionization chamber dosimetry in inverse planned IMRT fields

    … two independent calculations for the number of monitor units used in patient treatment plans. The relationship between monitor units and absorbed dose to water is sophisticated for MLC-based IMRT. Verification measurements of absorbed dose to water with ionization chambers in MLC-based IMRT …

    mcgill Repository record for Characterizing ionization chamber dosimetry in inverse planned IMRT fields (opens in a new tab)

  3. The Advantages of Collimator Optimization for Intensity Modulated Radiation Therapy

    … script. The evaluation of the plans included the monitor units (MU), the maximum dose of the plan, the maximum dose to organs at risk (OAR), the conformity index (CI) and the number of fields that are calculated to split. Compared to the CA0 plans, the monitor units decreased on average by 6% for …

    fau Repository record for The Advantages of Collimator Optimization for Intensity Modulated Radiation Therapy (opens in a new tab)

  4. A Comparative Analysis of Conventional MLC Based IMRT and Solid Compensator Based IMRT Treatment Techniques

    … treatments may result indelivery of very large monitor units (MUs) through very small fields where electronicequilibrium may be compromised. This also raises some concerns in terms of thescattered dose to areas outside the main treatment volume. The goals of this study were toevaluate the …

    ohiolink Repository record for A Comparative Analysis of Conventional MLC Based IMRT and Solid Compensator Based IMRT Treatment Techniques (opens in a new tab)

  5. Συγκριτική μελέτη διαφόρων τεχνικών ακτινοθεραπείας για την ακτινοβόληση ευμεγεθών αριστερών μαστών

    … το βαθμό διαμόρφωσης (modulation degree) και τα Monitor Units του κάθε πλάνου θεραπείας. Η τεχνική Sliding Window - IMRT επιτυγχάνει καλύτερη κάλυψη για περιστατικά ευμεγεθών αριστερών μαστών και ταυτόχρονα μικρότερη δυνατή μέση δόση στην καρδιά συγκριτικά με τις υπόλοιπες τεχνικές. Οι τεχνικές …

    athens Repository record for Συγκριτική μελέτη διαφόρων τεχνικών ακτινοθεραπείας για την ακτινοβόληση ευμεγεθών αριστερών μαστών (opens in a new tab)

  6. New method of collecting output factors for commissioming linear accelerators with special emphasis on small fields and intensity modualted readiation therapy

    … levels in the dose calculations and associated monitor units (MUs) for Intensity Modulated Radiation Therapy (IMRT). The parameters of commissioning the Novalis linear accelerator (linac) on the Eclipse Treatment Planning System (TPS) led to the study of challenges collecting data for very small …

    fau Repository record for New method of collecting output factors for commissioming linear accelerators with special emphasis on small fields and intensity modualted readiation therapy (opens in a new tab)

  7. Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location

    … with MC. This exact plan with the same beam Monitor Units (MUs) was recalculated over each respiratory phase. The results show that the PB algorithm has a 2.3-2.4% less overestimation at the maximum exhalation phase than the maximum inhalation phase when compared to MC. Significantly smaller …

    fau Repository record for Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location (opens in a new tab)

  8. Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy

    … Absolute dose, relative dose measurements, and monitor units were the main characteristics that were examined to decide which energy was the best for treatment. Source-to-axis distances (SAD) of 100cm measurements were taken at depths of 10cm and 5cm, respectively.

    fau Repository record for Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy (opens in a new tab)

  9. Study of wedged asymmetric photon beams

    … dose calculation. Algorithms for calculating monitor units (MUs) in wedged asymmetric photon beams as implemented in treatment planning systems have their limitations. In this work, the dose calculations for rectangular wedged asymmetric fields by the Eclipse treatment planning system were …

    ubc Repository record for Study of wedged asymmetric photon beams (opens in a new tab)

  10. Development of Graphical User Interfaces (GUI) Software and Databases for Radiation Therapy Applications

    … has been developed for various package including monitor unit calculation programming, TG51, prostate seed implant double check interface, stereotactic radio surgery (SRS) monitor unit calc programming and various query and report windows. This application has diversified package for radiation …

    ohiolink Repository record for Development of Graphical User Interfaces (GUI) Software and Databases for Radiation Therapy Applications (opens in a new tab)

  11. Validation of radiation treatment planning with a pseudo-CT derived from MR images

    … by keeping the same field parameters and monitor units. Dose point calculation and gamma index was used to access the dose accuracy. The point dose calculation agreement and the percentage of points passing the gamma index are excellent for the pseudo-CT and bulk methods with very minimal …

    missouri Repository record for Validation of radiation treatment planning with a pseudo-CT derived from MR images (opens in a new tab)

  12. Film dosimetry of intensity modulated beams

    … makes a manual verification of the number of monitor units difficult to perform. Consequently, before treatment, patient-specific quality assurance must be done in order to ensure that the delivery agrees with the plan; this process involves a measurement of 2D dose distribution in a phantom. …

    mcgill Repository record for Film dosimetry of intensity modulated beams (opens in a new tab)

  13. Dosimetric Consequences of the Parotid Glands Using CT-To-CBCT Deformable Registration During IMRT For Late Stage Head And Neck Cancers

    … performed on the weekly CBCTs using the original monitor units. The parameters for evaluation of our method were: the changes in volume of the PTVs and parotid glands, the dose coverage of the PTVs, the lateral displacement in the Center of Mass (COM), the mean dose, and Normal Tissue Complication …

    fau Repository record for Dosimetric Consequences of the Parotid Glands Using CT-To-CBCT Deformable Registration During IMRT For Late Stage Head And Neck Cancers (opens in a new tab)

  14. Radiotherapy dosimetry of the breast : Factors affecting dose to the patient

    … correction for the breast density indicated that monitor units are lower by an average 3% compared to a bulk density corrected plan assuming a density of 1g.cm-3. The average dose estimated from TLD in build-up caps placed on the patient surface was 0.99 of the prescribed dose. This shows that the …

    ucl Repository record for Radiotherapy dosimetry of the breast : Factors affecting dose to the patient (opens in a new tab)

  15. An Evaluation of HyperArc Treatment Planning and Workflow for Two Distinct Use Cases

    … HyperArc for this set of plans also used fewer monitor units at 733.4 MU compared to 834.4 MU for VMAT; this translates to a faster treatment delivery times and can ultimately reduce scatter.

    creighton Repository record for An Evaluation of HyperArc Treatment Planning and Workflow for Two Distinct Use Cases (opens in a new tab)

  16. Evaluation of volumetric modulated arc therapy and quality assurance based on Monte Carlo simulation

    … an optimization process able to adjust the Monitor Units and reconstruct the dose-volume histogram on the patient CT. Several clinical cases, previously planned with different treatment planning systems and verified with different commercial solutions were selected in order to test …

    sevilla Repository record for Evaluation of volumetric modulated arc therapy and quality assurance based on Monte Carlo simulation (opens in a new tab)

  17. Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging

    … values of phantom thickness, field size, and monitor units showed good agreement, with the great majority of points within ±3% of TPS dose. The method was evaluated on 20 patients, spanning multiple body sites and treatment techniques (334 fields). Excluding lung treatments, the mean dose …

    calgary Repository record for Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging (opens in a new tab)

  18. Investigations on dynamic intensity modulated photon fields in radiation therapy

    … A dosimetric verification technique used to monitor the dynamic beam delivery for IMRT plans is introduced. The design considerations and clinical evaluation of a QA phantom, facilitating the measurement of IMRT dose distribution and conversion of photon fluence to machine deliverable monitor …

    ubc Repository record for Investigations on dynamic intensity modulated photon fields in radiation therapy (opens in a new tab)

  19. Direct optimization of 3D dose distributions using collimator rotation

    … significantly less linac radiation output (monitor units or MU) while maintaining equivalent dose distribution quality compared to plans generated with the conventional fluence based approach. Furthermore with an improved collimator rotation speed, the RAO plans should be executable in the …

    ubc Repository record for Direct optimization of 3D dose distributions using collimator rotation (opens in a new tab)

Page 1 of 2