Results 1 to 17 of 17 for “"multimodal monitoring"”

  1. Non-invasive Multimodal Monitoring in Traumatic Brain Injury

    … a non-invasive, continuous optical system for monitoring ICP and cerebral oxygenation. Using backscattered brain optical signals, it leverages cerebral pulsatile photoplethysmograms (PPGs) and non-pulsatile near-infrared spectroscopy (NIRS) signals to assess ICP and oxygenation. The innovation …

    city-london Repository record for Non-invasive Multimodal Monitoring in Traumatic Brain Injury (opens in a new tab)

  2. An integrated real-time system for multimodal monitoring of Traumatic Brain Injury (TBI)

    <p>The goal of this work is to develop a multimodal monitoring system for the purpose of monitoring Traumatic Brain Injury (TBI) patients in neurological intensive care units. Multimodal monitoring refers to the science of acquisition and analysis of multiple parameters with the aim of identifying …

    ohiolink Repository record for An integrated real-time system for multimodal monitoring of Traumatic Brain Injury (TBI) (opens in a new tab)

  3. Computational modelling of brain energy metabolism and circulation in the neonatal animal model

    … tissue such as ATP, phosphocreatine and lactate. Multimodal monitoring with NIRS and MRS simultaneously gives a more complete picture of the metabolic state of the brain. The model has been compared with extensive multimodal data from piglets: both averaged, from brief anoxia studies, and …

    ucl Repository record for Computational modelling of brain energy metabolism and circulation in the neonatal animal model (opens in a new tab)

  4. From Multimodal Electrophysiology to EEG-Based Clinical Inference for Acute Brain Injury

    … worldwide. Early detection and continuous monitoring of neurological deterioration are essential for timely intervention and improved outcomes, yet current approaches are limited by logistical complexity, invasiveness, workflow burden, and the absence of integrated analytical frameworks. …

    jhu Repository record for From Multimodal Electrophysiology to EEG-Based Clinical Inference for Acute Brain Injury (opens in a new tab) Embargoed until 2028-05-01

  5. Surgeon directed transcranial motor evoked potential spinal cord monitoring in spinal deformity surgery: A review of viability, safety and efficacy

    … risk of neurological injury. Neurophysiological monitoring allows early identification of intraoperative cord injury facilitating early intervention which has a better prognosis. Although multimodal monitoring is the ideal, resource constraints make surgeon directed intra-operative transcranial …

    cape-town Repository record for Surgeon directed transcranial motor evoked potential spinal cord monitoring in spinal deformity surgery: A review of viability, safety and efficacy (opens in a new tab)

  6. Mathematical modelling supported monitoring of cerebrovascular physiology: From theory to clinical application

    … neurosurgical management increasingly rely on multimodal physiological monitoring, clinical decision-making remains largely driven by simplified thresholds and incomplete interpretation of coupled dynamics between cerebral blood flow, arterial blood pressure, intracranial pressure (ICP), …

    cambridge Repository record for Mathematical modelling supported monitoring of cerebrovascular physiology: From theory to clinical application (opens in a new tab)

  7. Instrumentation and methods for frequency-domain and multimodal near-infrared spectroscopy

    … near-infrared spectroscopy (NIRS) device and for multimodal brain measurements was implemented. Different techniques were applied to human and newborn lamb brain studies. A method to detect light leakage in NIRS measurements was developed. The FD instrument, developed at the Helsinki University of …

    aalto Repository record for Instrumentation and methods for frequency-domain and multimodal near-infrared spectroscopy (opens in a new tab)

  8. Towards the Development of Multimodal Aptamer Biosensors for Chronic Cardiac Care

    … with diabetes. Despite the need for molecular monitoring in many diseases, only glucose monitoring has reached maturation for long term wearable use. In the United States, heart disease continues to plaguepatients and hospitals incurring massive financial and time costs. Despite these needs …

    ohiolink Repository record for Towards the Development of Multimodal Aptamer Biosensors for Chronic Cardiac Care (opens in a new tab)

  9. Multi-sensor monitoring for in-situ defect detection and quality assurance in laser-directed energy deposition

    … is the lack of an automated, real-time quality monitoring and control system during the production process. This results in a substantial reliance on manual, empirical offline process planning and parameter tuning, leading to increased labour costs and potential product quality compromises. This …

    nanyang Repository record for Multi-sensor monitoring for in-situ defect detection and quality assurance in laser-directed energy deposition (opens in a new tab)

  10. Comprehensive monitoring of the injured brain by hybrid diffuse optics: towards brain-oriented theranostics

    (English) In the intensive care, the multimodal monitoring of the patient is crucial. The systemic physiology is routinely and comprehensively monitored but the practical monitoring of the brain is lacking. Hybrid diffuse optics (DO) has a potential to fill this gap by combining diffuse correlation …

    barcelona Repository record for Comprehensive monitoring of the injured brain by hybrid diffuse optics: towards brain-oriented theranostics (opens in a new tab)

  11. Analyses of Bicycle and Pedestrian Trail Traffic: New Tools for Modeling User Expenditures and Demand

    … – over three orders of magnitude – across the monitoring stations included in the study; (2) daily trail traffic is highly correlated with weather, and the parabola form of weather parameters works well for modeling variables such as temperature, where trail use is associated with warmer …

    umn Repository record for Analyses of Bicycle and Pedestrian Trail Traffic: New Tools for Modeling User Expenditures and Demand (opens in a new tab)

  12. Near infrared spectroscopy for the non-invasive characterization of cerebrovascular reactivity in moderate and severe traumatic brain injury

    … injury following TBI. Contemporary methods of monitoring CVR continuously rely on invasive intracranial pressure (ICP) monitoring. This limits the use of these ICP-based indices of CVR to the acute phase of TBI where ICP monitoring is already indicated. As a result, continuous examination of …

    manitoba Repository record for Near infrared spectroscopy for the non-invasive characterization of cerebrovascular reactivity in moderate and severe traumatic brain injury (opens in a new tab)

  13. Multimodal assessment of Parkinson's disease using electrophysiology and automated motor scoring

    … hardware to develop a new system to facilitate monitoring of the severity of Parkinson's disease signs and symptoms in human patients. Off -line analysis of data collected with the system was subsequently shown to allow discrimination between normal and simulated parkinsonian conditions. The …

    gatech Repository record for Multimodal assessment of Parkinson's disease using electrophysiology and automated motor scoring (opens in a new tab)

  14. Coupling Remote Sensing and Modelling to Monitor the Spatial Distribution and Trends of Surface Temperature and Ice Thickness on Sub-Arctic Lakes

    … at high latitudes. This research adopts a multimodal monitoring approach to address these limitations by combining remote sensing data with spatially distributed modelling to study and monitor the trends and spatial distribution of LST, LIT and LIP. In this study, a retrieval algorithm was …

    wilfrid-laurier Repository record for Coupling Remote Sensing and Modelling to Monitor the Spatial Distribution and Trends of Surface Temperature and Ice Thickness on Sub-Arctic Lakes (opens in a new tab)

  15. Impact of sedation and vasopressors on in vivo cerebrovascular reactivity in adult moderate/severe traumatic brain injury (TBI)

    Traumatic brain injury (TBI) is one of the leading causes of death and disability both in Canada and worldwide. Despite TBIs’ extensive impact on healthcare there has been limited overall improvement over the past four decades. However, the secondary injuries associated with TBI (those being the …

    manitoba Repository record for Impact of sedation and vasopressors on in vivo cerebrovascular reactivity in adult moderate/severe traumatic brain injury (TBI) (opens in a new tab)

  16. Předzpracování EEG v rámci multimodálního monitoringu EEG - fMRI

    … více biosignálů v jednom čase. Multimodální monitoring může obsahovat EEG, fMRI, EKG či EMG záznamy. V této práci jsou navrženy vhodné metody pro předzpracování dat pocházejících z multimodálního monitoringu EEG-fMRI. Cílem práce je udělat průzkum možných artefaktů vznikajících při fúzi …

    cz-tech Repository record for Předzpracování EEG v rámci multimodálního monitoringu EEG - fMRI (opens in a new tab)

  17. Electroencephalography of premature infants

    … infants had continuous conventional video-EEG monitoring. The EEGs from cohort 1 were recorded as soon as possible after birth, while the EEGs from cohort 2 were recorded within the first 12 hours of age, continued for approximately 72 hours with further short follow-up recordings at 32 weeks …

    cork Repository record for Electroencephalography of premature infants (opens in a new tab) Embargoed