Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"nebuliser"”.

  1. Clinical and psychological factors associated with nebuliser adherence among adults with cystic fibrosis

    Background: Daily nebuliser use is crucial for people with cystic fibrosis (CF) to stay healthy, but average adherence is only 35-50%. Making nebuliser use ‘habitual’ (i.e. automatic) may aid adherence, but extant CF literature has mainly focused on treatment burden and factors involving conscious …

    whiterose Download PDF for Clinical and psychological factors associated with nebuliser adherence among adults with cystic fibrosis (opens in a new tab)

  2. Inductively Coupled Plasma-Optical Emission Spectrometry For Forensic Analysis

    … the stability of the injector gas flowrate and nebuliser derived pressure pulses. Discrete nebulisation has been investigated for the analysis of small fragments of a variety of metal alloys which could be encountered in casework investigations. External contamination together with alloy …

    plymouth Repository record for Inductively Coupled Plasma-Optical Emission Spectrometry For Forensic Analysis (opens in a new tab)

  3. Proniosome formulations for pulmonary drug delivery

    … Omron Micro Air NEU22 (passively vibrating-mesh) nebulisers. The Pari and Aeroneb Pro nebulisers generated higher aerosol and drug outputs compared with the Omron nebuliser. Whilst drug output was around 80% for the Pari and the Aeroneb Pro, it was around 70% for the Omron. Similarly, droplet size …

    cent-lancashire Download PDF for Proniosome formulations for pulmonary drug delivery (opens in a new tab)

  4. Poly (D,L-Lactide) based microspheres for pulmonary delivery of proteins

    … of the rehydrated powders using an ultrasonic nebuliser resulted in improved aerosilisation performance compared to the air-jet nebuliser. When tested in vitro using a macrophage cell line, the PLA microspheres system exhibited a low cytotoxicity and the microspheres induced phagocytic activity …

    aston Download PDF for Poly (D,L-Lactide) based microspheres for pulmonary delivery of proteins (opens in a new tab)

  5. Antimony Speciation By Chromatographic Sample Introduction To Plasma Spectroscopy

    … first time. A fundamental investigation of the nebuliser/spray chamber assembly was carried out in terms of the effect on the quality of the chromatographic separations. It was found that the resolution was strongly dependent upon choice of nebuliser and spraychamber. Five nebulisers and two …

    plymouth Repository record for Antimony Speciation By Chromatographic Sample Introduction To Plasma Spectroscopy (opens in a new tab)

  6. Inductively Coupled Plasma Atomic Emission Spectroscopy for the Analysis of Trace Elements in Boron Materials

    … the sample quantity was limited a recirculating nebuliser was developed and tested. A xl0 improvement in efficiency over conventional methods of nebulisation was achieved without any deterioration in sensitivity or precision. A microprocessor controlled version provided a suitable approach to …

    aston Repository record for Inductively Coupled Plasma Atomic Emission Spectroscopy for the Analysis of Trace Elements in Boron Materials (opens in a new tab) Download PDF for Inductively Coupled Plasma Atomic Emission Spectroscopy for the Analysis of Trace Elements in Boron Materials (opens in a new tab)

  7. Surface acoustic waves nebulisation for pulmonary drug delivery

    … low power consumption. The main advantage as a nebuliser, for pulmonary drug delivery, lies with their ability to provide control of the aerosolized droplet size. Another advantage, compared to a commercially available nebuliser, is given by the high frequencies (>1MHz) employed during the …

    glasgow Repository record for Surface acoustic waves nebulisation for pulmonary drug delivery (opens in a new tab) Download PDF for Surface acoustic waves nebulisation for pulmonary drug delivery (opens in a new tab)

  8. Metody testování inhalátorů

    … and the methods used for testing inhalers and nebulisers. The second part presents experimental measurements performed using the Aerogen Solo vibrating mesh nebuliser with fluorescently labelled particles. The aerodynamic particle size distribution was characterised using both the Next …

    brno-tech Repository record for Metody testování inhalátorů (opens in a new tab)

  9. Nanostructured Lipid Carriers (NLCs) for Cancer Therapy via Pulmonary Drug Delivery

    … different nebulisation devices (i.e., air-jet nebuliser and vibrating mesh nebuliser) for TC-NLC suspension formulations; and a mono dose inhaler (i.e., dry powder inhaler (DPI)) for the spray-dried (SD) SD-TC-NLC powder formulations. The spray drying technique was performed using two different …

    liverpool-jm Download PDF for Nanostructured Lipid Carriers (NLCs) for Cancer Therapy via Pulmonary Drug Delivery (opens in a new tab) Embargoed until 2027-05-08

  10. Development of lentiviral airway gene therapy aerosol delivery techniques for cystic fibrosis

    … developed ultrasonic surface acoustic wave (SAW) nebuliser produced significantly lower levels of gene expression than bolus delivery. This led to examination of an intra-tracheal sprayer, the MADgic™ atomisation device, which demonstrated promising results on delivering the vector as a spray, in …

    adelaide Repository record for Development of lentiviral airway gene therapy aerosol delivery techniques for cystic fibrosis (opens in a new tab)

  11. Isotopic analysis of environmental samples using inductively coupled plasma mass spectrometry

    … micro-sample introduction systems: the PFA micro-nebuliser, working at 150 μL/min, and the torch integrated sample introduction system (TISIS), working at 20 μL/min. Under optimal conditions and using ammonia as damping gas, repeatability was 0.12 ± 0.03 and 0.17 ± 0.04 % RSD at 10 ng/mL of Pb, …

    ghent Repository record for Isotopic analysis of environmental samples using inductively coupled plasma mass spectrometry (opens in a new tab)

  12. Φαρμακοκινητική της εισπνεόμενης και ενδοφλεβίως χορηγούμενης κολιστίνης σε ασθενείς με λοίμωξη κατώτερου αναπνευστικού στη μονάδα εντατικής θεραπείας

    … dose of 3 MIU and 5 MIU, using a vibrating mesh nebuliser, for VAP caused by extensively drug-resistant Gram-negative pathogens was assessed. Blood samples and mini- bronchoalveolar lavage (mini-BAL) was performed post-dose at 1, 4 and 8 h. Concentrations of CMS and formed colistin in mini-BAL …

    greece Repository record for Φαρμακοκινητική της εισπνεόμενης και ενδοφλεβίως χορηγούμενης κολιστίνης σε ασθενείς με λοίμωξη κατώτερου αναπνευστικού στη μονάδα εντατικής θεραπείας (opens in a new tab)

  13. Protein Drugs for Inhalation: Investigating the Stability of Dry Powder Formulations during Production and Application

    … could be redispersed and applied using a nebuliser. This would be an option to deliver the protein drug to the lung of patients that are not able to use a DPI device, due to e. g. poor lung function.

    cau-kiel Repository record for Protein Drugs for Inhalation: Investigating the Stability of Dry Powder Formulations during Production and Application (opens in a new tab)

  14. Directly-coupled Chromatography - Analytical Atomic Spectroscopy For Trace Metal Speciation

    … flame atomisers but sample introduction via the nebuliser was avoided. Applications are reported using both minibore HPLC for alkyllead speciation and fast protein liquid chromatography for speciating zinc in human serum. Applications of the above techniques for determining organometallic species …

    plymouth Repository record for Directly-coupled Chromatography - Analytical Atomic Spectroscopy For Trace Metal Speciation (opens in a new tab)

  15. The effect of posture on the regional deposition of an inhaled aerosol

    … delivered in a controlled manner using a closed nebuliser circuit that regulated the subjects' respiratory pattern. The total and regional pulmonary deposition of the aerosol was assessed using planar 2D imaging and SPECT aligned with MRI. data sets demonstrated that posture had a significant …

    soton Download PDF for The effect of posture on the regional deposition of an inhaled aerosol (opens in a new tab)

  16. Symptoms and adherence in adults with Cystic Fibrosis: understanding the complex relationship

    … the relationship between symptoms and objective nebuliser adherence in adults with CF. In relation to symptom tracking, the findings suggest that this could be something which is useful and feasible to some patients living with CF and also HCP’s. This thesis offers a unique contribution in that …

    sheffield-hallam Repository record for Symptoms and adherence in adults with Cystic Fibrosis: understanding the complex relationship (opens in a new tab) Download PDF for Symptoms and adherence in adults with Cystic Fibrosis: understanding the complex relationship (opens in a new tab)

  17. Real-time bioaerosol analysis in the healthcare environment

    … minimum. These peaks corresponded to observed nebuliser use on the ward. WIBS analysis of the two nebulised therapy drugs used on the ward defined a characteristic fluorescence signature for nebuliser aerosols. This allowed design of a threshold filter to remove interferent nebulised drugs from …

    cork Repository record for Real-time bioaerosol analysis in the healthcare environment (opens in a new tab)

  18. Improved Sample Introduction Systems for Inductively Coupled Plasma Optical Emission Spectrometry and Their Application to the Analysis of Simple and Complex Matrices

    … In the first project, a conventional ultrasonic nebuliser was modified to replace the heater/condenser with an infrared heated pre-evaporation tube. In continuation from previous works with pre-evaporation, the current work investigated the effects of heating with infrared block and rope heaters …

    queens Repository record for Improved Sample Introduction Systems for Inductively Coupled Plasma Optical Emission Spectrometry and Their Application to the Analysis of Simple and Complex Matrices (opens in a new tab)

Page 1 of 2