Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 43 for “"nebulizers"”.

  1. Experimental evaluation of medical nebulizers

    S narastajúcimi problémami v globálnych atmosférických podmienkach stúpa aj výskyt respiračných ochorení a s ním súvisí aj nárast dopytu po efektívnejších zariadeniach na ich liečbu. Medzi takéto zariadenia patrí aj medicínsky nebulizér, ktorý sa často využíva pri inhalačnej terapii. Aj keď bola …

    brno-tech Repository record for Experimental evaluation of medical nebulizers (opens in a new tab)

  2. Vibration-Induced Atomization Of Liquids With Application To Ultrasonic Medical Nebulizers

    … on the operation of ultrasonic vibrating mesh nebulizers does not entirely explain the principles by which these devices atomize liquid medication. Many of the studies on this topic assume a spray or extrusion mode of droplet generation, but it can be demonstrated that the high frequency …

    nodak Repository record for Vibration-Induced Atomization Of Liquids With Application To Ultrasonic Medical Nebulizers (opens in a new tab)

  3. Aerosolization Studies of Zn-DTPA Using Nebulizers for Decorporation of Internal Radioactive Contamination

    Zn-DTPA is a chelator to treat internal radioactive contamination with FDA approval. A jet nebulizer and an ultrasonic nebulizer were used to aerosolize the Zn-DTPA solution. The particle size distribution was measured by a particle time-of-flight analyzer and cascade impactor. Two evaluation …

    carleton Repository record for Aerosolization Studies of Zn-DTPA Using Nebulizers for Decorporation of Internal Radioactive Contamination (opens in a new tab)

  4. Aerosol Characterization and Analytical Modeling of Concentric Pneumatic and Flow Focusing Nebulizers for Sample Introduction

    A concentric pneumatic nebulizer (CPN) and a custom designed flow focusing nebulizer (FFN) are characterized. As will be shown, the classical Nukiyama-Tanasawa and Rizk-Lefebvre models lead to erroneous size prediction for the concentric nebulizer under typical operating conditions due to its …

    toronto-retro Repository record for Aerosol Characterization and Analytical Modeling of Concentric Pneumatic and Flow Focusing Nebulizers for Sample Introduction (opens in a new tab)

  5. Importance of stability of pharmaceutical formulations

    … affected by nebulization using vibrating mesh nebulizers. Lastly, the effect of nebulization using vibrating mesh nebulizers on stability of tissue-type plasminogen activator (tPA) and single-chain urokinase plasminogen activator (scuPA), being studied for the treatment of inhalational …

    texas Repository record for Importance of stability of pharmaceutical formulations (opens in a new tab)

  6. Nebulizer-based Systems to Improve Pharmaceutical Aerosol Delivery to the Lungs

    Combining vibrating mesh nebulizers with additional new technologies leads to substantial improvements in pharmaceutical aerosol delivery to the lungs across therapeutic administration methods. In this dissertation, streamlined components, aerosol administration synchronization, and/or Excipient …

    vcu Repository record for Nebulizer-based Systems to Improve Pharmaceutical Aerosol Delivery to the Lungs (opens in a new tab)

  7. Development and characterization of concentric capillary nebulizer used in inductively coupled plasma analysis /

    … Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for …

    brock Repository record for Development and characterization of concentric capillary nebulizer used in inductively coupled plasma analysis / (opens in a new tab)

  8. Development of an inhalational formulation of Coenzyme Q₁₀ to treat lung malignancies

    … output characteristics from vibrating-mesh nebulizers. Subsequently, this method was used, together with analysis of particle size distribution, zeta potential, and rheology, to further evaluate the factors influencing the capability of this nebulizer system to continuously and steadily …

    texas Repository record for Development of an inhalational formulation of Coenzyme Q₁₀ to treat lung malignancies (opens in a new tab)

  9. Numerical and Experimental Investigation and Optimization of Particle Size Distribution in a Medical Jet Nebulizer Using A Multiphase Multiscale Approach

    Jet nebulizers are a common form of nebulizer used for aerosol treatment. They are known to function poorly in children under five due to differences in patient attributes. They must reduce their mass median aerodynamic diameter (MMAD) to work more effectively. This allows more medicine to be …

    rit Repository record for Numerical and Experimental Investigation and Optimization of Particle Size Distribution in a Medical Jet Nebulizer Using A Multiphase Multiscale Approach (opens in a new tab)

  10. The Presence of Legionellae in Respiratory Devices: Convenience Sampling of Idaho Long Term Care Facilities

    … Positive Airway Pressure (CPAP) units, jet nebulizers, portable room humidifiers, and respiratory ventilation equipment have been identified in context of a Legionellosis outbreak. However, a systematic search for the presence of Legionella bacteria in respiratory devices outside of a …

    boise Repository record for The Presence of Legionellae in Respiratory Devices: Convenience Sampling of Idaho Long Term Care Facilities (opens in a new tab)

  11. Generation and Delivery of Charged Aerosols to Infant Airways

    … than aerosols from conventional vibrating mesh nebulizers in invasively ventilated infants using a combination of small particle size, synchronization with inspiration and appropriate charge. The BIL model produced in this work can be used to test clinically relevant methods of administering …

    vcu Repository record for Generation and Delivery of Charged Aerosols to Infant Airways (opens in a new tab)

  12. Geochemical Analysis By Inductively-Coupled Plasma Optical Emission Spectroscopy Using Slurry Atomization

    … plasma has been investigated. High-solids nebulizers, spray chambers and torches have been designed and optimized for aqueous slurry introduction. The influence of particle size on sample introduction and atomization efficiency was shown to be paramount. Kaolin particles greater than 8 um …

    plymouth Repository record for Geochemical Analysis By Inductively-Coupled Plasma Optical Emission Spectroscopy Using Slurry Atomization (opens in a new tab)

  13. Development of the vibrating capillary nebulizer sample introduction system for inductively coupled plasma mass spectrometry

    … limited by self-aspiration of pneumatic nebulizers which causes band broadening in the separation profile. Being the VCN operates absent of pneumatic gas, it performs CE without the influence of self-aspiration. In this work, we describe the modifications made to the sample introduction …

    iastate Repository record for Development of the vibrating capillary nebulizer sample introduction system for inductively coupled plasma mass spectrometry (opens in a new tab)

  14. Carrier-free high-dose dry-powder inhaler formulation of non-steroidal anti-inflammatory drugs

    … inhaler (DPI). Other inhalation devices such as nebulizers require significantly more time for drug delivery and metered dose inhalers may be incapable of metering sufficiently large drug doses. Therefore, carrier-free DPIs have been explored for large drug dose delivery. IBU exists as the stable …

    texas Repository record for Carrier-free high-dose dry-powder inhaler formulation of non-steroidal anti-inflammatory drugs (opens in a new tab)

  15. Effervescent proliposomes for aerosol delivery to paranasal sinuses

    … and Pari Sprint (non-pulsating technology) nebulizers were used for liposome delivery to a nasal cast. Choice of carrier did not affect the liposome’s ability to withstand shearing. A novel system of a Sar-Gel® (water indicating paste) coated clear nasal cast fixed to a two-stage impinger …

    cent-lancashire Download PDF for Effervescent proliposomes for aerosol delivery to paranasal sinuses (opens in a new tab)

  16. Χορήγηση εισπνεόμενων αντιβιοτικών στους βαρέως πάσχοντες

    … Colistin methanesulfonate, Colistin, Nebulizers, Clinical efficacy, Toxicity, Multidrug-resistant, Ventilator associated pneumonia, Aerosolized, Inhaled, Antibiotics ΑΠΟΤΕΛΕΣΜΑΤΑ Η χορήγηση των εισπνεόμενων αντιβιοτικών, και ειδικά της κολιστίνης που έχει μελετηθεί εκτενέστερα, …

    athens Repository record for Χορήγηση εισπνεόμενων αντιβιοτικών στους βαρέως πάσχοντες (opens in a new tab)

Page 1 of 3