Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"neck-shaft angle"”
-
Influence of Design Parameters on Cup-Stem Orientations for Impingement free Range of Motion in Hip Implants
… influence of design parameters such as head-neck ratio, neck-shaft angle, oscillation angle, and stem offset on cup-stem orientations such as cup inclination, cup anteversion, and stem antetorsion. Stems with head-neck ratio lower than 2.3 and neck shaft angle greater than 135 did not …
-
Navigation and Patient Specific Instrumentation in Shoulder Arthroplasty
… arthroplasty component height, version and neck shaft angle and therefore outcomes. The purpose of this study is to develop and utilize navigation to execute the osteotomy. 3D printed models were used to develop a navigation technique, and then to execute planned osteotomies. Free hand, …
-
Μελέτη της συσχέτισης των γεωμετρικών και ανατομικών παραμέτρων του εγγύς μηριαίου για τον προσδιορισμό της πύλης εισόδου ενδομυελικών ήλων
… always lied a few millimeters behind the femoral neck axis (mean=3.51.5 mm). In the coronal plane the optimum entry point lied at a location dependent on the femoral neck-shaft angle. Linear regression on the data showed that the optimal entry point is clearly correlated to the true 3D femoral …
-
ΣΥΓΚΡΙΤΙΚΗ ΜΕΛΕΤΗ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΗΛΟΥ ΠΛΑΚΑΣ ΜΕΤΑΒΛΗΤΗΣ ΓΩΝΙΑΣ BOUSQUET ΚΑΙ ΤΟΥΟΛΙΣΘΑΙΝΟΝΤΟΣ ΚΟΧΛΙΑ-ΠΛΑΚΑΣ ΣΤΗ ΧΕΙΡΟΥΡΓΙΚΗ ΑΝΤΙΜΕΤΩΠΙΣΗ ΤΩΝ ΚΑΤΑΓΜΑΤΩΝ ΤΗΣ ΠΕΡΙΤΡΟΧΑΝΤΗΡΙΔΑΣ ΠΕΡΙΟΧΗΣ
… OF THE IMPLANT AND VARUS DEFORMATION OF THE NECK SHAFT ANGLE WERE ASSESSED BY AP X-RAYS. IN STABLE FRACTURES REGARDING THE MIGRATION OF THE IMPLANT AND VARUS DEFORMATION OF THE NECK SHAFT ANGLE NO SIGNIFICANT DIFFERENCES WERE ENCOUNTERED. IN UNSTABLE FRACTURES: REGARDING MIGRATION THE SLIDING …
-
Relação do índice pélvico-trocantérico com a Síndrome Dolorosa do Grande Trocanter
… pain syndrome and to identify if the femoral neck shaft angle is smaller on the symptomatic side when compared to the asymptomatic side in patients with the unilateral greater trochanteric pain syndrome. A study was carried out to compare patients with the diagnosis of greater trochanteric …
-
Sex Differences in the Femur and Acetabulum: Biomechanical Analysis with Forensic Significance
… in biacetabular breadth and femoral functional angles, and whether these differences are significant enough to provide a forensically relevant equation for estimating sex with the femur. Sexual dimorphism in pelvic dimensions and femoral angles of 30 males and 30 females were analyzed using …
-
Fundamentals of the Biomechanical Characteristics Related to the Loading of Reverse Total Shoulder Arthroplasty Implants and the Development of a Wear Simulation Strategy
… of changes in implant configuration. Decreasing neck-shaft angle and cup depth was not found to affect joint load or muscle forces. Increasing glenosphere diameter increased adduction range of motion (ROM), but also slightly increased joint load. The contact mechanics of RTSA were then …
-
An Analysis of Primary Stability of Stemless Humeral Implants in Shoulder Arthroplasty
… respect to the fixation of stemless implants is neck shaft angle. This was evaluated in terms of primary fixation in a clinically available stemless reversed implant. This was also assessed using a computational framework for a larger range of inclinations. The results of both works were in …
-
Acromial Insufficiency Fractures in Reverse Total Shoulder Arthroplasty: A Biomechanical Study
… lateralization, humeral lateralization, and neck-shaft angle. Acromial strain was measured by 4 strain gauges placed along the acromion and scapular spine. Total deltoid force was measured as a secondary outcome. All specimens were tested in 4 planes of elevation including 0° and 90° …
-
Cultural Behaviors and Their Influence on the Proximal Femur: Comparisons of Postural Behavior, Occupation, and Subsistence-Settlement Between a Pre-Contact and Historic Sample
… as well. Skeletal data such as proximal femur angles and activity markers contribute to the understanding of subsistence-settlement trends and postural behavior of the mortuary complex. Femoral neck version is associated with postural behaviors such as squatting and kneeling. The neck-shaft …
-
Range of Motion and Impingement in Reverse Shoulder Arthroplasty
… was used to determine the effects of humeral neck-shaft angle, socket depth, glenosphere diameter and eccentricity on range of motion and adduction deficit. A retentive humeral cup depth increased adduction deficit by 14 degrees and reduced range of motion by 26 degrees. A decreased neck-shaft …
-
The Effects of Cam Femoroacetabular Impingement on Mechanical Hip Joint Loading
… symptomatic individuals had a lower femoral neck-shaft angle and reduced pelvic range of motion. Second, using the classified participants, hip joint loading was determined for the various severities of cam FAI, with respect to alterations in hip contact forces and anatomical considerations. …
-
Επιδημιολογία και μορφολογική μελέτη των καταγμάτων του άνω πέρατος μηριαίου: συσχέτιση με τον τύπο κατάγματος
… between fractures occurring in the femoral neck and the trochanteric region. To this end, we conducted a prospective cohort study involving the radiographic images and Dual-energy X-ray absorptiometry (DEXA) measurements of 70 individuals over 65 years of age who were admitted to the …
-
The Biomechanics of Reverse Shoulder Arthroplasty
… effect on ROM, followed by glenosphere position. Neck-shaft angle had the largest effect on inferior scapular impingement, followed by glenosphere position. Stability is determined primarily by increasing joint compressive forces and, to a lesser extent, by increasing humerosocket depth. There are …
-
Enhancing our Understanding of Outcomes and Determinants of Outcomes Following Proximal Humerus Fractures in Adults
… arm, and whosefracture had a varus fracture neck shaft angle, or a disrupted medial hinge. My risk tools identified the use of a bone graft, and fixation with a nail or wire (vs. a plate) in patients treated with fixation, poor bone quality in patients treated with replacement, and younger …
-
Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό
… Head Offset, Head Diameter, Head Center Height, Neck-Shaft Angle and Isthmus Position) were calculated and demonstrated great variability. 2. For medullary canal edge detection, it was found that instead of a constant threshold value, a local value must be computed separately for every image, …
-
Διατροχαντήρια κατάγματα του μηριαίου και ενδομυελική οστεοσύνθεση με ήλους με ένα ή δύο κεντρικούς κοχλίες: τυχαιοποιημένη, ελεγχόμενη μελέτη (randomized controlled trial - RCT)
… evaluated postoperatively were: 1. The neck-shaft angle, 2. The reduction gap on the profile radiograph, 3. The TAD distance, 4. The Ω, Ω1, and Ω2 distances, 5. The angle X formed by the transcervical cochlea and the axis of the neck. Regression and classification trees and Chi-Square …
-
Ontogeny of Lower Limb Morphology and Proportions in the Dinaledi Hominins
… the development of proximal diaphyseal shape and neck-shaft angle are conserved within Homininae, but that neck shape may develop differently in bipeds than non-bipeds. The absolute shape of the femoral neck, however, markedly differs between the Dinaledi sample and modern humans, with greater …
-
A Study of the Growth and Development of the Human Fetal Hip Joint
… of femur (LHF) is elongated, and the femoral angles are abnormal. These are measureable characteristics. However, no previous studies have given quantitative data for several dimensions of this joint in a sample of fetuses, at regular intervals of age, throughout the fetal period.</p> <p>The …
-
Motion and Crosslinked Polyethylene Wear in Reverse Total Shoulder Arthroplasty
… based on in vivo data suggested that smaller neck shaft angles of te implant might reduce polyethylene damage and also suggested that 1.25 million cycles in our joint wear simulator provided a good representation of 1 year in vivo. It is likely that the use of XLPE in the RTSA may reduce the …