Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"needle probe"”.

  1. Modified Transient Hot-Wire Needle Probe for Experimentally Measuring Thermal Conductivity of Molten Salts

    … these properties at high temperatures. Here, a needle probe is developed, which modifies principles from existing instrumental techniques in order to experimentally measure the thermal conductivity of molten salts with reduced error. An analytical heat transfer model is developed to characterize …

    byu Repository record for Modified Transient Hot-Wire Needle Probe for Experimentally Measuring Thermal Conductivity of Molten Salts (opens in a new tab) Download PDF for Modified Transient Hot-Wire Needle Probe for Experimentally Measuring Thermal Conductivity of Molten Salts (opens in a new tab)

  2. Implementation of Wire Mesh Sensor Principles into New Needle Probe for Characterization of Two-Phase Flow Parameters

    … To solve this problem, a new type of needle probe sensor was designed and tested in this thesis, working on the same operating principles of the wire mesh sensor. The needle probe can be moved anywhere in the 2-D plane of interest and increases the number of measurement sites in areas …

    tamu Repository record for Implementation of Wire Mesh Sensor Principles into New Needle Probe for Characterization of Two-Phase Flow Parameters (opens in a new tab)

  3. In-Pile Thermal Conductivity Measurement Methods for Nuclear Fuels

    … in a laboratory setting. A transient needle probe method adapted from American Standard Test Method standards was also used to measure temperature-dependent thermal conductivity of surrogate fuel rod materials for temperatures ranging from room temperature to 400 °C. The needle probe …

    utahstate Repository record for In-Pile Thermal Conductivity Measurement Methods for Nuclear Fuels (opens in a new tab)

  4. Experimental and Theoretical Characterization of Molten Salt Thermal Conductivity

    … material properties, which---in the case of the needle probe device---induced unaccounted physical changes that limited its accuracy and repeatability. Sparse thermal conductivity data in general is exacerbated by a limited fundamental understanding of molecular energy transfer in liquids. This …

    byu Repository record for Experimental and Theoretical Characterization of Molten Salt Thermal Conductivity (opens in a new tab) Download PDF for Experimental and Theoretical Characterization of Molten Salt Thermal Conductivity (opens in a new tab)

  5. Thermal conductivity of soils for energy foundation applications

    … the thermal response test was compared to the needle probe and thermal cell laboratory methods. For each method, the main sources of error were investigated. Previously, the needle probe transient temperature data was analysed by visual inspection or rules of thumb. A new analysis method was …

    soton Download PDF for Thermal conductivity of soils for energy foundation applications (opens in a new tab)

  6. Improving Devices to Measure the Thermal Conductivity of Molten Halide Salts

    … which this work seeks to fill by improving the Needle Probe-a modified transient hot wire probe originally used by Merritt et al to measure the thermal conductivity of FLiNaK- measuring two new salts, and exploring new materials for use with molten salts. Improvements made to the Needle Probe …

    byu Repository record for Improving Devices to Measure the Thermal Conductivity of Molten Halide Salts (opens in a new tab) Download PDF for Improving Devices to Measure the Thermal Conductivity of Molten Halide Salts (opens in a new tab)

  7. Integrated Raman spectroscopy and mass spectrometry for heterospectral tissue imaging

    … the thesis also explore a polarised Raman needle probe for rapid bulk structural and molecular tissue analysis. The first technique combines Raman Spectroscopy and DESI-mass spectrometry imaging to enable Raman spectroscopic identification of specific tissue lipids. A custom-developed …

    kings Repository record for Integrated Raman spectroscopy and mass spectrometry for heterospectral tissue imaging (opens in a new tab) Download PDF for Integrated Raman spectroscopy and mass spectrometry for heterospectral tissue imaging (opens in a new tab)

  8. Near-field scanning optical microscopy with laser trapping

    … microscopy with a tapered fibre or a metallic needle probe, particle-trapped near-field scanning optical microscopy offers several advantages such as no need of distance control, high signal collection efficiency, and easy replacement of a particle probe. In consideration of the major problems …

    vu-aus Download PDF for Near-field scanning optical microscopy with laser trapping (opens in a new tab)

  9. Concurrent Assessment of Knee Cartilage Morphology and Bone Microarchitecture using Contrast-Enhanced HR-pQCT Imaging

    … the articular cartilage thickness measured by needle probe. Measures of cartilage morphology were found to be significantly different between MRI, needle probing and CEHR- pQCT. Bone microarchitecture was found to be significantly different in CEHR-pQCT, where cortical bone mineral density …

    calgary Repository record for Concurrent Assessment of Knee Cartilage Morphology and Bone Microarchitecture using Contrast-Enhanced HR-pQCT Imaging (opens in a new tab)

  10. Electrical Impedance Spectroscopy with Multi-modal Tissue Discrimination for Ultrasound-Guided Targeted Biopsy

    … ultrasound (US) is used to place a biopsy needle in lesion(s) identified via MRI for sampling. The lesion is not always visible in US, so proper needle placement is not guaranteed. Thus, false-negative results occur often, causing uncertainty in treatment. This thesis proposes an …

    carleton Repository record for Electrical Impedance Spectroscopy with Multi-modal Tissue Discrimination for Ultrasound-Guided Targeted Biopsy (opens in a new tab)

  11. Effect of non-condensable gases (NCG) on Effective Thermal Conductivity of oil sands

    … using a rapid unsteady state technique. A needle probe emitting heat as a line source is used to determine the effect of NCG saturation on ETC of oil sands at different temperatures and pressures. The experimental data is later fitted into existing ETC models to develop modified …

    calgary Repository record for Effect of non-condensable gases (NCG) on Effective Thermal Conductivity of oil sands (opens in a new tab)

  12. Characterizing Temperature-Dependent Properties of Fat for Improving High Intensity Focused Ultrasound Simulations

    … Measurements were performed using a dual needle probe for thermal conductivity and diffusivity, differential scanning calorimetry for specific heat capacity, radiation force balance for attenuation, and through-transmission methods for velocity. Results showed that thermal conductivity and …

    byu Repository record for Characterizing Temperature-Dependent Properties of Fat for Improving High Intensity Focused Ultrasound Simulations (opens in a new tab) Download PDF for Characterizing Temperature-Dependent Properties of Fat for Improving High Intensity Focused Ultrasound Simulations (opens in a new tab)

  13. Segmentation, co-registration, and correlation of optical coherence tomography and X-ray images for breast cancer diagnostics

    … to be over a few millimeters. In the case of a needle probe, OCT could provide images of the vicinity of the probe tip, allowing for better localization and identification of abnormal tissue. In the intraoperative case, OCT can be utilized to evaluate tumor margins and lymph nodes that have been …

    uiuc Repository record for Segmentation, co-registration, and correlation of optical coherence tomography and X-ray images for breast cancer diagnostics (opens in a new tab)

  14. Das Dämpfungsverhalten des Tibiaplateaus bei Gonarthrose im Endstadium

    … waren die Messungen der Knorpeldicke mittels „Needle-probe“, der subchondrale Knochendichte in der Computertomographie-Osteoabsorptiometrie (CT-OAM) sowie der histopathologischen Veränderungen im Mankin, OARSI und Aho Score. Im Indentationsversuch zeigte sich eine inhomogene Verteilung des IM. …

    freiburg-diss Repository record for Das Dämpfungsverhalten des Tibiaplateaus bei Gonarthrose im Endstadium (opens in a new tab)

  15. Surface Enhanced Raman Scattering (SERS) Substrates and Probes

    … remote contact and minimally invasive probes inside the specimen are needed. This research work is divided in: (1) development of Surface Enhanced Raman Scattering (SERS) substrate using gold coated etched aluminum foil, (2) development of the SERS probe using the aluminum based …

    lsu-thes Repository record for Surface Enhanced Raman Scattering (SERS) Substrates and Probes (opens in a new tab)

  16. Tracking Thermal and Structural Properties of Melt-Freeze Crusts in the Seasonal Snowpack

    … during the winter of 2009-10 using a heated needle probe. Thermal conductivity of two cold lab crusts increased during freezing and subsequently decreased in the presence of strong vertical temperature gradients, while that of natural crusts had no discernible trends under weak temperature …

    calgary Repository record for Tracking Thermal and Structural Properties of Melt-Freeze Crusts in the Seasonal Snowpack (opens in a new tab)

  17. Impedance Sensors for Fast Multiphase Flow Measurement and Imaging

    … The first one is a complex permittivity needle probe which can detect the phases of a multiphase flow at its probe tip by simultaneous measurement of the electrical conductivity and permittivity at up to 20 kHz repetition rate. Two-dimensional images of the phase distribution in pipe …

    qucosa-diss

Page 1 of 2