Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 20 for “"needle-type"”

  1. Stratified Arrays of Needle-Type Oxidation Reduction Potential Sensors

    … and characterization of stratified arrays of needle-type oxidation reduction potential sensors. The sensors were fabricated by wet etching glass probes using the principle of meniscus etching, where the balance of forces between the surface tension and the weight of the etchant meniscus …

    ohiolink Repository record for Stratified Arrays of Needle-Type Oxidation Reduction Potential Sensors (opens in a new tab)

  2. Needle-Type Sensor For In Situ 3-D Multi-Analyte Mapping

    Needle-type microelectrode array sensors for in situ 3D mapping have been successfully developed, and applied to monitoring in biofilms and plant root environment (rhizosphere). Commercial sensors are simply too large (~1 cm diameter) to perform in situ measurements. While pulled glass pipettes …

    ohiolink Repository record for Needle-Type Sensor For In Situ 3-D Multi-Analyte Mapping (opens in a new tab)

  3. MEMS Needle-Type Multi-Analyte Microelectrode Array Sensors for In Situ Biological Applications

    … and recess sensor tips. In this work, individual needle-type MEA sensors for measuring oxidation reduction potential (ORP), dissolved oxygen (DO), and phosphate were first developed and, subsequently, integrated into a single multi-analyte MEA. The ORP and DO sensors had the recessed tip …

    ohiolink Repository record for MEMS Needle-Type Multi-Analyte Microelectrode Array Sensors for In Situ Biological Applications (opens in a new tab)

  4. CHARACTERIZATION OF DYNAMICALLY-ETCHED NANOPROBE ARRAYS FOR <i>IN SITU</i>NEEDLE-TYPE SENSORS

    … tips can be used as an alternative to microneedles and in other applications requiring in situ sensing

    ohiolink Repository record for CHARACTERIZATION OF DYNAMICALLY-ETCHED NANOPROBE ARRAYS FOR <i>IN SITU</i>NEEDLE-TYPE SENSORS (opens in a new tab)

  5. Effect of Needle Type and Placement of Entry on the Incidence of Coring and Self-Sealing Capability in Multiuse Vials

    … practices. This study aims to compare two needle types and needle placement protocols to simulate a multi-use vial scenario. The experiment design involved repeated punctures of saline-filled vials to assess factors contributing to coring incidence and self-sealing capability. The study …

    ohiolink Repository record for Effect of Needle Type and Placement of Entry on the Incidence of Coring and Self-Sealing Capability in Multiuse Vials (opens in a new tab)

  6. Poly(aniline) microelectrodes for ascorbate measurements

    … aim of this research was the production of a needle type microelectrode to monitor rapid changes of ascorbic acid, AA, in physiological fluids. Poly(aniline), PANi, composites have been shown to be excellent electrocatalytic surfaces for the oxidation of NADH and AA. Electrodeposition of PANi …

    soton Repository record for Poly(aniline) microelectrodes for ascorbate measurements (opens in a new tab)

  7. Design and characterization of Electrochemical Sensors for Organic Bioelectronics

    … presence of interfering species and design of a needle-type, sub-micrometric OECT sensor for spatially resolved detection of biological Dopamine concentrations. Chapter IV – Development of an OECT pH sensor. Characterization of the electrochemical transducer and functionalization of the OECT gate …

    bologna Repository record for Design and characterization of Electrochemical Sensors for Organic Bioelectronics (opens in a new tab)

  8. Investigation into climatic effects on the growth and genetic structure of sky island ponderosa pine

    … of two partially sympatric species, the variable needle Pinus ponderosa var. brachyptera (3- and mixed-needle) that prefers cool and moist conditions, and the 5-needle P. arizonica that prefers hot and dry conditions. The objective of this research program is to determine how disturbance–that is …

    msu Repository record for Investigation into climatic effects on the growth and genetic structure of sky island ponderosa pine (opens in a new tab)

  9. Current measurements in electrospinning

    … the experiments are carried out using conductive needle. By substituting the standard electrode with penetrating electrode, the current dropped to zero when the syringe was empty. An average of 0.26E-6 Amps reduction on the amount of measured current is observed when the syringe is filled with …

    njit Repository record for Current measurements in electrospinning (opens in a new tab)

  10. Characterizations of alloying Cu effect on electrochemical reactions of Al-Cu solid solution alloys

    … and spectral imaging of specially prepared Al-Cu needle-type samples show that Cu is readily enriched at the alloy interface by a range of exposure regimens including those that induce pitting. These results suggest the possibility of local Cu enrichment at incipient pit sites by metastable …

    ohiolink Repository record for Characterizations of alloying Cu effect on electrochemical reactions of Al-Cu solid solution alloys (opens in a new tab)

  11. Investigations of potentially implantable glucose sensors

    … substantially shorten the stabilization time. A needle-type miniature glucose sensor for in vivo monitoring was developed. Its performance was evaluated both in vitro and in vivo. A multi-layer inner .membrane was demonstrated to successfully eliminate electrochemical interferences. The in vivo …

    ku Repository record for Investigations of potentially implantable glucose sensors (opens in a new tab)

  12. Electrochemical Microsensors for In Situ Monitoring of Chemical Compounds in Engineered and Natural Aquatic Systems

    The adaption of needle-type electrochemical microsensor (or microelectrode) techniques to environmental science and engineering systems has transformed how we understand mass transport in biotic and abiotic processes. Their small tip diameter (5-20μm) makes them a unique experimental tool for …

    ucf Repository record for Electrochemical Microsensors for In Situ Monitoring of Chemical Compounds in Engineered and Natural Aquatic Systems (opens in a new tab)

  13. OPTICAL COHERENCE TOMOGRAPHY FOR NEUROSURGEY AND CANCER RESEARCH

    … been pursued in this work. A forward-imaging needle-type OCT probe was developed which can fit into minimally invasive tools (I.D. ~ 1mm), detect the at-risk blood vessels, and identify tissue micro-landmarks. This promising guidance tool improves the safety and the accuracy of needle-based …

    maryland Repository record for OPTICAL COHERENCE TOMOGRAPHY FOR NEUROSURGEY AND CANCER RESEARCH (opens in a new tab)

  14. Inzidenz, Risikofaktoren und Krankenhausverweildauer des postpunktionellen Kopfschmerzes nach Spinalanästhesie in der Unfallchirurgie und Geburtsmedizin

    … OBS 6 vs. 4 days, p<0.0005). Gender (only ORT), needle gauge, needle type and anesthesiological expertise were no significant risk factors of PDPH. Conclusion: The incidence of PDPH was different in both groups but considerably lower than in literature. Age, constitution and performing the …

    fu-berlin Repository record for Inzidenz, Risikofaktoren und Krankenhausverweildauer des postpunktionellen Kopfschmerzes nach Spinalanästhesie in der Unfallchirurgie und Geburtsmedizin (opens in a new tab)

  15. Development of potentially implantable glucose sensors.

    A novel glucose oxidase based needle-type glucose microsensor has been developed for subcutaneous glucose monitoring. The new configuration greatly facilitates the deposition of uniform enzyme and polymer films so that sensors with satisfactory in vitro characteristics (upper limit of linear range …

    arizona-thes Repository record for Development of potentially implantable glucose sensors. (opens in a new tab)

  16. Emulsion Characterization Study for Improved Bilgewater Treatment and Management

    … monitoring emulsion stability. Additionally, a needle-type pH microsensor and fluorescence spectroscopy were used for analyzing mass transfer at the oil-water interface. Water quality of extracted bilgewater showed to highly vary between vessels (e.g., conductivity: 1.74 -- 24 mS/cm, chemical …

    ucf Repository record for Emulsion Characterization Study for Improved Bilgewater Treatment and Management (opens in a new tab)

  17. AN ANALYSIS OF THE BUCKLING BEHAVIOR OF SPINAL ANESTHESIA NEEDLES

    The use of large gauge (G) spinal anesthesia needles can increase complications due to buckling. The purpose of this study was to, first, create a model to repeatably simulate and quantify the behavior of spinal needles in buckling and, second, quantify the buckling behavior of spinal anesthesia …

    wfu Repository record for AN ANALYSIS OF THE BUCKLING BEHAVIOR OF SPINAL ANESTHESIA NEEDLES (opens in a new tab)

  18. Análise bromatológica de carnes antes e após o processamento para obtenção de charque

    … copper 0.057 and 0.039 ppm in the case of needle-type meat (CPA and CHPA), 68.04% and 44.17%, protein 13 , 72, and 24.42 g/100g of sample, 1.137 in the ash and 12.68 g / 100g of sample, and the minerals calcium 17.11 and 12.89 ppm; sódio0, 123 and 4.871 g / L, sodium chloride 0.312 and …

    brazil-ufrn Repository record for Análise bromatológica de carnes antes e após o processamento para obtenção de charque (opens in a new tab)

  19. A Viscosity-Dependent Affinity Sensor for Continous Monitoring of Glucose in Biological Fluids

    … analyte. Recently, subcutaneous implantable needle-type sensors became commercially available for continuous glucose monitoring. However, these devices require frequent calibrations and are lacking accuracy and reliability. They are based on electrochemical detection, which is strongly …

    epfl Repository record for A Viscosity-Dependent Affinity Sensor for Continous Monitoring of Glucose in Biological Fluids (opens in a new tab)

  20. Fabrication, Characterization and Modeling of Aligned Polyacrylonitrile-Based Electrospun Carbon Nanofibers

    … on the collector surface for wire and mesh type collectors compared to foil collectors. Nanofibers electrospun with wire type collector show the highest alignment due to the intense uniform electric field and tensile properties of carbonized nanofiber films. Electrode geometry is another …