Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 91 for “"negative sequence"”.
-
Negative sequence impedance measurement for distributed generator islanding detection
… distributed generator networks by measuring negative sequence impedance differences between islanded and utility connections. Extensive testing was conducted on a commercial building and 25 kV distributed generator fed network by measuring naturally occurring and artificially injected …
-
Turn-to-turn fault detection in transformers using negative sequence currents
… efficient protection technique which is based on negative sequence currents. Using this protection technique, it is possible to detect minor internal turn-to-turn faults in power transformers. Also, it can differentiate between internal and external faults. The discrimination is achieved by …
-
Detailed investigation of negative sequence current compensation technique for stator shorted turn fault detection of induction motors.
… health and to predict any incipient failures. Negative sequence current monitoring is one of the well-known condition monitoring applications that capable of identifying stator faults in induction motor as well as producing fast and reliable results using a simple measurement technique. …
-
Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers
… Digital relays are capable of computing the negative sequence current on both primary and secondary sides of the transformer along with the phase difference between these two negative sequence currents. By using both phase and magnitude information, negative sequence current could be used to …
-
Negative-sequence current control of hybrid cascaded three-level and multilevel power converter for high voltage direct current (HVDC) transmission
… research challenge undertaken is to integrate a sequence analyzer and controller technology that was proven to have worked for other converter topologies with an emerging hybrid multilevel converter, i.e., H3LC. This thesis presents an unbalanced PCC current regulation control method with …
-
Balancing Asymmetrical Load Using a Static Var Compensator
… and railway, enhances the amount of unbalance or negative sequence components. Alongside asymmetrical load, further increase in negative sequence components is introduced due to the network inherent asymmetry i.e. untransposed transmission. Thus, they are usually excessive and exceeds standards at …
-
A method of measuring negative-phase-sequence currents in a three-phase system
A method of measuring the negative-sequence current in an unbalanced three-phase circuit. A four-winding current transformer, in conjunction with a phase shift network and an alternating current ammeter, was used for obtaining a current proportional to, and in phase with, the negative-sequence …
-
Transmission grid strength analysis and operation of inverter-based microgrids
… the motor load. However, the magnitude of the negative-sequence current an inverter can supply is limited by its relatively low rated current. Therefore, we investigate the range of negative-sequence current the inverter can supply and derive formulas to determine the minimum capacity required …
-
Addressing the Performance of Distance Relays in Presence of Inverter Based Resources
… This work focuses on the impact of inverters on negative sequence component-based directional elements that assist distance relays in identifying the direction of fault current, causing incorrect tripping of relays and missing out on in-zone faults. The main reasons for these misoperations are …
-
Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors
… TensorFlow Hub. In this method, positive and negative sequence current magnitudes and the negative sequence current angle are used as the fault indices, and they are transformed into layers of color image representations of the motor's operating state. By fine-tuning pre-trained CNNs on these …
-
Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System
… IEEE 2800 Standard mandates that IBRs generate negative-sequence current during low-voltage ride-through (LVRT) conditions. The 2800 Standard requires that the IBRs' negative-sequence current lead the negative-sequence voltage by 90-100 degrees to emulate SGs and reduce the likelihood of …
-
Unbalance Compensation for AC Microgrid With Solid-State Transformer
… a novel unbalance compensation system for negative-sequence current suppression with high level power compensation capability integrated into a constant 50 Hz microgrid system. It is implemented at the high-volage sides of 50Hz delta-wye transformers supplying power at their low-voltage …
-
Impact of Inverter-Based Resources on Grid Dynamics
… simulator. It is found that inverters can act as negative-sequence sources to inject negative-sequence currents into the grid during the grid restoration period and thus can adversely impact the performance of protection schemes based on negative sequence components and potentially cause relay …
-
Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems
… are motor current spectrum analysis (MCSA), negative sequence components analysis utilizing a symmetrical components transformation, and the space-vector pendulous oscillation method. The applicability of these diagnosis techniques to this case-study experimental interior permanent- magnet …
-
Single-turn sensitive stator inter-turn fault detection of induction machines
… induction machines by detecting positive and negative sequence line current third harmonic components. Initially, inadequacy has been identified in a diagnostic scheme based on negative sequence quantities of the machine and critical improvements have been realized to suppress the effects of …
-
Fault current generation by STATCOM
… in the power grid since they do not have a negative impact on the environment as the conventional power plants. Renewable energy resources are not required, by the current grid codes, to contribute to restore the voltage stability. Moreover, they do not contribute to the short circuit …
-
Frequency scan based stability analysis of power electronic systems
… screening technique based on the positive and negative sequence impedance/admittance can also be used for stability screening in grid-connected PESs. Although this technique is widely used in industry and generally gives correct indications of stability, it can give erroneous results due to the …
-
A universal grid-forming VSC control for future power system
… to enable independent control of positive- and negative sequence components. An enhanced AC fault current control that employs both positive and negative-sequence current control is proposed. An additional voltage balancing control is also developed to retain the AC voltage controller for fault …
-
Proteção diferencial de transformadores de potência utilizando a transformada Wavelet com efeitos de borda
… the performance of the traditional methods, a negative sequence differential element with high sensitivity has been used in association with the commom harmonic blocking and harmonic restraint functions. However, internal faults and other disturbances associated to the power transformer …
-
Modeling, Control, and Operation of a Grid-Tied Solar Photovoltaic Inverter in Unbalanced Conditions
… This control scheme regulates only positive sequence currents. More recently, the research focuses on unbalance GFL controls to conduct more studies and investigations needed regarding the converter’s negative sequence current contribution during such short- circuit faults. Thus, a proper …
Page 1 of 5