Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 36 for “"nephelometry"”.
-
Development of a Nephelometry Camera and Humidity Controlled Cavity Ring-Down Transmissometer for the Measurement of Aerosol Optical Properties
A Nephelometry camera (NephCam) and Humidity Controlled Cavity Ring-Down Transmissometer (HC-CRDT) were developed for the determination of aerosol optical properties. The NephCams use a reciprocal geometry relative to an integrating nephelometer; a diode laser illuminates a scattering volume …
-
Infrared spectrophotometric analysis of serum triglycerides
… method makes use of light scattering indices (nephelometry) to assess serum triglycerides. Work in this area has been done by Helman, Blevins, and Gleason (12). Their results were consistent, in most cases, with those of the colorimetric method. Of the thirty Fredrickson classifications they …
-
Physical and Chemical Properties of Laboratory and Ambient Aerosols Related to Climate Change
… 4 and NH4NO3 aerosol using an RH scanning nephelometry system. Correcting for nephelometer non-idealities and RH of the sample improved the agreement between measured and predicted total scattering coefficients (sigmasp) at RH = 80% from 35% to 11%. The closure experiment revealed the …
-
A Nephelometric Study of Silver Bromide Sols
… measures the quantity of reflected light. Nephelometry posses certain advantages not to be found in other quantitative methods. The average worker is accustomed in most cases to estimating relatively large amounts of substances by gravimetric means, the limitations of which are well known. …
-
Development and Evaluation of a Near-infrared (1047 nm) Photoacoustic-Nephelometer Spectrometer for Detection and Optical Characterization of Black Carbon Aerosol
… such as Photoacoustic spectroscopy and nephelometry overcome these deficiencies associated with filter-based sampling methods. This thesis discusses the design and development of a novel, integrated photoacoustic-nephelometer (IPN) spectrometer operating at 1047 nm wavelength for …
-
Η προκαλσιτονίνη και τα αντιγόνα μυκήτων ως βιολογικοί δείκτες πρώιμης διάγνωσης και πρόγνωσης βακτηριακών και μυκητιακών λοιμώξεων σε ουδετεροπενικούς και μη ουδετεροπενικούς ασθενείς
… measured by an immunoluminometric assay, CRP by nephelometry and antigens by Platelia Elisa. Low values of PCT were observed in patients with systemic aspergillosis and systemic candidiasis while high values of PCT (>1 ng/ml) were observed in patients with gram(-) bacteremia and severe sepsis. …
-
Immunochemical Techniques in Clinical Analysis
… by free antigen as detected by automated nephelometry was investigated. The assay procedure was optimized for maximum sensitivity. The characteristics of the optimized system are described and with the available instrumentation, the lower level of detection of free digoxin (a cardiac …
-
Acylphosphine oxides as photoinitiators
… than the other commercial photoinitiators. Laser nephelometry and bulk polymerisation techniques were investigated as possible photoinitiator screening methods. Their limitiations are reported. The efficiency of an acylphosphine oxide and a commercial photoinitiator were compared for the …
-
Τα επίπεδα της προκαλσιτονίνης του αίματος ως ενδεικτική παράμετρος βακτηριακής λοίμωξης σε πάσχοντες από εμπύρετη ουδετεροπενία
… by an immunochemiluminometric assay and CRP by nephelometry. Median PCT on the first day of fever was 8 23 ng/ml in the field of bacteremia compared to 0.86 ng/ml in localized bacterial infections (P=0.017). Median PCT in severe sepsis was 2.62 ng/ml compared to 0.57 ng/ml in clinically …
-
Ανοσολογική αποκατάσταση παιδιών με καρκίνο μετά την ολοκλήρωση της αντινεοπλασματικής αγωγής
… serum IgG, IgA and IgM levels studied by nephelometry. Qualitative and quantitative evaluation of humoral responses to previous immunizations included serum antibody levels to mumps and measles (qualitative) and to rubella and polio (quantitative). Furthermore, skin tests (volar forearm) …
-
PREPARATION AND PROPERTIES OF ANTIGEN- OR ANTIBODY-ENZYME CONJUGATES EMPLOYED IN ENZYME IMMUNOASSAYS.
… with the standard peroxidase procedure. Rate nephelometry was established as a reliable method to measure apparent immunological reactivities of the conjugates at μg/ml levels. Hill plot treatment of the rate nephelometric data shows that the immunoprecipitin reactions may be cooperative, with …
-
Copper status in multiple trauma patients: measurement of copper balance, serum copper and ceruloplasmin
… and patient discharge by ASS and rate nephelometry inmunoprecipition, respectively. Eight patients received parenteral nutrition (PN). Three received intravenous glucose/electrolyte infusions (IV). urine (n=11) and nasogastric losses (n=8) were statistically greater than normal …
-
Concentration and mass deposition measurements in two-phase jet flow with applications to railroad friction management systems
… (LDA)/phase Doppler anemometry (PDA) and planar nephelometry are excellent to provide accurate local measurements of concentration but are expensive and complicated to set up and operate. Our proposed measurement method is based on light extinction and is much easier to set up and use. This …
-
Επίδραση της λαπαρασκοπικής χολοκυστεκτομής στον άξονα αυξητικής ορμόνης (GH-IGF'S) και στρες (stress)
… assay (ELISA), while CRP was measured by nephelometry. ANOVA with repeated measures and Tukey’s post-hoc test were used to evaluate changes in serum measurements. RESULTS: The laparoscopic cholecystectomy resulted in a significant postoperative increase in circulating levels of IL-6 …
-
Early detection of renal dysfunction in pediatric patients and young adults with type 1 diabetes
… serum and Urinary NGAL(ELISA) cystatin C (nephelometry), YKL-40(ELISA) and GDF-15(ELISA) weremeasured at enrollment and after 12-15 months. GFR was calculated with thebedside Schwartz formula (S-GFR), Cystatin C Schwartz formula (CysC-eGFR) andthe Lund strategy formula (L-eGFR).Results: At …
-
Experimental Investigations of Fused Filament Fabrication for Applications to Affordable Scientific Hardware
… is developed to provide both colorimetry and nephelometry. This approach resulted in equipment that costs between 7.5 and 15 times less than current commercially available tools. A syringe pump was designed and manufactured using an open-source hardware and software. The design, bill of …
-
Development and Application of a Method for Gas-phase Temperature Measurements in Particle-laden Flows
… the laser light scattered by particles (particle nephelometry). The accuracy and precision of the two-colour LIF method was assessed for a series of particle materials and diameters, including materials that luminesce following absorption of the excitation laser light. The results show that …
-
A model for the incongruent dissolution of pyrite
… absorption, the other for total sulfate by nephelometry, a method which proved itself to be superior to the more conventional turbidimetric method. Solution phase data indicated the relatively constant production rate of iron until 48 hours at which point, there is a noticeable increase in …
-
The influence of jet precession on particle distributions.
… The laser diagnostic technique, called planar nephelometry, enables non-intrusive, quantitative, instantaneous, planar measurements of particle distributions without the need to identify individual particles. The methodology to quantify particle clusters is designed to enable statistical …
-
Systematic studies of commodity particulate matter air pollution sensors
… often qualified as ’low-cost’, are based on nephelometry and they could increase the spatiotemporal resolution of current monitoring. However, questions remain about their performance variation, including with PM characteristics and meteorological factors. There is no current agreed best …
Page 1 of 2