Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 770 for “"noise level"”.

  1. High noise level microphones used in aircraft.

    … of three of the present "State of the Art" high noise level microphones. They are the M-87/AIC and M-87/AIC+ (EV 693) both made by Electro-Voice and the HNL bone conduction microphone made by SETCOM Corporation. The advantages and disadvantages of using a bone conduction microphone over a boom …

    nps Repository record for High noise level microphones used in aircraft. (opens in a new tab)

  2. Measuring noise level reduction using an artificial noise source

    … near airports may be subjected to significant noise levels due to aircraft flyovers. Aircraft noise is particularly annoying when compared to other traffic noises due to its intermittent nature. While noise control is typically performed at the source, sound insulation programs are in place to …

    gatech Repository record for Measuring noise level reduction using an artificial noise source (opens in a new tab)

  3. Analysis of optimization methods on chemical processes with high noise level

    … for processes with significant variation, or noise. Classical techniques are not effective when the response improvementto-noise ratio is small. In this realm of optimization, statistical techniques are necessary to achieve optimal conditions. Statistical methods such as the Student's t-test …

    ut-knoxville Repository record for Analysis of optimization methods on chemical processes with high noise level (opens in a new tab)

  4. PERFORMANCE OF KERNEL-BASED METHODS IN ANALYZING UNDERWATER NOISE LEVEL STATISTICS

    … through a statistical analysis of physical noise sources, specifically wind speed at the surface of the water. We developed a simple classifier that can categorize ambient noise data as being associated with high wind speed or low wind speed, which demonstrates a distinct difference between …

    nps Repository record for PERFORMANCE OF KERNEL-BASED METHODS IN ANALYZING UNDERWATER NOISE LEVEL STATISTICS (opens in a new tab)

  5. The effects of distance from the source on jet noise spectra and perceived noise level contours

    … of distances for the purpose of comparing jet noise sources is expensive. A proposed technique for solving this problem is to make acoustic measurements on a constant radius spherical surface surrounding the noise source and extrapolate these data to various distances. A model is presented that …

    ut-knoxville Repository record for The effects of distance from the source on jet noise spectra and perceived noise level contours (opens in a new tab)

  6. The Effect of Age, Noise Level, and Frequency on Loudness Matching Functions of Normal Hearing Listeners with Noise Masking

    … hearing loss and in simulated hearing loss with noise masking. This study looked at possible differences in loudness recruitment with age, noise level, and frequency. Participants from two age groups were tested. Group A included participants aged 18 to 30 years and Group B included participants …

    byu Repository record for The Effect of Age, Noise Level, and Frequency on Loudness Matching Functions of Normal Hearing Listeners with Noise Masking (opens in a new tab) Download PDF for The Effect of Age, Noise Level, and Frequency on Loudness Matching Functions of Normal Hearing Listeners with Noise Masking (opens in a new tab)

  7. The Development of a Vertical-Axis Wind Turbine Wake Model for Use in Wind Farm Layout Optimization with Noise Level Constraints

    … urban environments near residential areas, the noise disturbance coming from the turbine blades is an important consideration in the layout of a wind farm. Noise restrictions may be imposed on a wind farm to limit the disturbance, often impacting the wind farm's power producing capability. Two …

    byu Repository record for The Development of a Vertical-Axis Wind Turbine Wake Model for Use in Wind Farm Layout Optimization with Noise Level Constraints (opens in a new tab) Download PDF for The Development of a Vertical-Axis Wind Turbine Wake Model for Use in Wind Farm Layout Optimization with Noise Level Constraints (opens in a new tab)

  8. A Comparative Study of Techniques for Non-monotonic Dependence with Emphasis on Sensitivity to Sample Size, Noise Level and Computational Attributes

    … segregated by three sample sizes and three noise levels. In addition, we assessed the computational time and peak memory (RAM) usage during computations for each of these methods. Next, we applied all methods on Cape Floristic Region (CFR) data to capture association between four pairs of …

    arkansas Repository record for A Comparative Study of Techniques for Non-monotonic Dependence with Emphasis on Sensitivity to Sample Size, Noise Level and Computational Attributes (opens in a new tab)

  9. A comparison between power line noise level field measurements and man-made radio noise prediction curves in the high frequency radio band

    Radio frequency noise is often the limiting factor in the ability of a communications receiver to discern a desired signal from man made interference. The predominate man made radio noise source in the high frequency radio band is gap type breakdown discharges on electric power distribution lines. …

    nps Repository record for A comparison between power line noise level field measurements and man-made radio noise prediction curves in the high frequency radio band (opens in a new tab)

  10. Quantification of directional hearing aid benefit : comparison of acceptable noise level, masked speech recognition threshold, ear canal signal-to-noise ratio, and abbreviated profile of hearing aid benefit

    … quantified physically with ear canal signalto- noise ratio (SNR), perceptually with masked speech recognition threshold (SRT) testing, and subjectively with formal questionnaires. An additional, behavioral method for quantifying the beneficial effects of directional microphones in hearing aids …

    ut-knoxville Repository record for Quantification of directional hearing aid benefit : comparison of acceptable noise level, masked speech recognition threshold, ear canal signal-to-noise ratio, and abbreviated profile of hearing aid benefit (opens in a new tab)

  11. Šiaulių miesto triukšmo šaltinių tyrimai /

    … of bachelor thesis – Analysis of Siauliai City Noise Sources. The objective – to perform research of noise sources in Šiauliai, determine territories that are most effected by the noise and provide solutions for reducing noise pollution. Herein the legislative norms of noise control and …

    vilnius Repository record for Šiaulių miesto triukšmo šaltinių tyrimai / (opens in a new tab)

  12. Šiaulių miesto triukšmo šaltiniai /

    Project target – to perform analysis of noise level in eight most noisy areas in Šiauliai city and propose tools for reduction of noise level. Noise levels were measured next to shopping centres „Akropolis“, „Tilžė“, „Bruklinas“ and „Saulės miestas“, near the factory of solid fuel boilers „Kalvis“, …

    vilnius Repository record for Šiaulių miesto triukšmo šaltiniai / (opens in a new tab)

  13. Autotransporto taršos poveikio įvertinimas Gegužių gatvės aplinkoje /

    The analysis of air pollution and noise level was held in Šiauliai city, in the environment of 6 apartment buildings on Gegužiai Street segment between Tilžės and S. Darius and S. Girėnas Streets. Air pollution, investigation of snow chemical contamination and measurement of noise of vehicles in …

    vilnius Repository record for Autotransporto taršos poveikio įvertinimas Gegužių gatvės aplinkoje / (opens in a new tab)

  14. The effect of passive and electronic amplitude-sensitive hearing protectors on the detection of a warning signal

    … to study earmuff wearers’ signal detection in noise performance and perceptions of comfort and acceptability with two amplitude-sensitive earmuffs as compared to their conventional counterparts. Passive and electronic amplitude-sensitive earmuffs were tested, represented by the EAR Ultra 9000 …

    vt Repository record for The effect of passive and electronic amplitude-sensitive hearing protectors on the detection of a warning signal (opens in a new tab)

Page 1 of 39