Showing 1 to 6 of 6 for “"non-loadbearing"”.
-
Fire Resistance Quantification of Non-Loadbearing Masonry Walls –Numerical Study
Non-loadbearing masonry walls, have a considerable capacity, from the fire perspective, to isolate part of the building's interior from flames, heat and the effect of smoke. This research focuses on quantifying the fire resistance of non-loadbearing masonry walls subjected to elevated temperatures. …
-
Minimum steel requirements for masonry walls : out-of-plane forces
… spacing of transverse reinforcement. Full size non-loadbearing walls were tested under monotonic quasi-static loading. Test results showed that for typical 8 feet (2.44 m) storey height walls, the main steel may be spaced at more than 4 feet (1.22 m) and full primary bending moment may still be …
-
The applicability of recycled waste paper as lightweight building materials
… aim was to develop an eco-friendly lightweight non-loadbearing block from recycled wastepaper without the use of cement as binder. This study specifically addressed the drawback of low strength development that usually occur with increasing wastepaper content in the existing …
-
Improving the Fire-Resistance Rating of Concrete Masonry Walls Through the Use of Insulations : An Experimental and Numerical Study
For non-loadbearing applications, the 15 cm blocks are usually used. They are lightweight, easy to install, and are cost-effective. The fire-resistance rating of the 15 cm block is about 1 h, while that of a 20 cm block is about 2 h. This reduced fire-resistance rating is due to smaller cells which …
-
TOWARDS THE RECONCILIATION OF THE EMPIRICAL AND RATIONAL DESIGN PROVISIONS OF CSA S304-14
… for unreinforced, vertically spanning, non-loadbearing, exterior concrete block walls subject to wind load result in less conservative outcomes than the rational design provisions. This discrepancy of design outcomes can indicate either the inadequate levels of safety of the empirical …
-
High Performance Reinforced Hemp-Lime Nanocomposite Construction Materials
… which were more than the minimum limit of loadbearing material. This material, therefore, due to its high compressive strength, used as the 'Core' load bearing element of the proposed wall in the absence of a timber framework. The 'Insulator' was developed using a water removal 'Solvent …