Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 93 for “"nuclear physics and radiation"”.

  1. The Determination of the Thermal Neutron Flux in a Research Reactor

    … of experiments, knowledge of the neutron flux, and of its spatial and spectral energy distribution is of great importance, not only for purposes of experimental reactor physics (e.g., determination of specific data with regard to a new reactor), and for reactor operation (e.g., determination of …

    creighton Repository record for The Determination of the Thermal Neutron Flux in a Research Reactor (opens in a new tab)

  2. Dirty bombs : the technical aspects of radiological dispersion devices

    … the ever-rising threat of terrorist attack and disruption of the economy and of daily activity, the potential strength of a radiological dispersion device must be evaluated. A "dirty bomb" is a weapon in the terrorist arsenal that is highly effective in creating chaos, panic and disruption. …

    nps Repository record for Dirty bombs : the technical aspects of radiological dispersion devices (opens in a new tab)

  3. LOW MOMENTUM TRANSFER MEASUREMENTS OF PION ELECTROPRODUCTION AND VIRTUAL COMPTON SCATTERING AT THE DELTA RESONANCE

    … at the Δ+(1232) resonance for Q2 = 0.04, 0.09, and 0.13 (GeV/c)2 utilizing the Jefferson National Accelerator Facility (JLab) pulsed beam and Hall A spectrometers. The new data extend the measurements of the Coulomb quadrupole amplitude to the lowest momentum transfer ever reached. The results …

    temple Repository record for LOW MOMENTUM TRANSFER MEASUREMENTS OF PION ELECTROPRODUCTION AND VIRTUAL COMPTON SCATTERING AT THE DELTA RESONANCE (opens in a new tab)

  4. Modeling of Outer Radiation Belt Electron Scattering due to Spatial and Spectral Properties of ULF Waves

    … (0.5-10 MeV) electrons in Earth's outer radiation belt (r = 3-7 RE, or L-shells: L = 3-7) interacting with magnetospheric Pc-5 (ULF) waves. This dissertation focuses on ideal models for short and long term electron energy and radial position scattering caused by interactions with ULF …

    wvu Repository record for Modeling of Outer Radiation Belt Electron Scattering due to Spatial and Spectral Properties of ULF Waves (opens in a new tab)

  5. Characterization of the MARS Neutron Detector

    … proposed. The process involved measuring tiny nuclear recoils that result from a neutrino scattering off of atomic nuclei. COHERENT made the first two measurements of CEvNS at the Spallation Neutron Source (SNS) and is working toward additional measurements there with the goal of observing the …

    duke Repository record for Characterization of the MARS Neutron Detector (opens in a new tab)

  6. Image-Based Radiopharmaceutical Imaging Tracer Dosimetry by Using Monte Carlo Simulation

    … Monte Carlo simulation package. Materials and Methods: We performed three dosimetry studies: 1) a simple point-source phantom 2) a MOBY (4D Mouse Whole Body) digital phantom; and 3) a mouse injected with a monoclonal antibody-based PET imaging agent (124I-hJAA-F11), with PET images acquired …

    buffalo Repository record for Image-Based Radiopharmaceutical Imaging Tracer Dosimetry by Using Monte Carlo Simulation (opens in a new tab)

  7. Investigation of the Dosimetric Impact of Patient Immobilization Device and Treatment Couch Structures in Prone Breast Radiation Therapy

    Purpose: In prone breast radiation, as the medial tangential beam usually passes through the immobilization board and couch, it is necessary to quantify the attenuation effect and the potential skin dose enhancement from these external structures when not included during the treatment planning …

    buffalo Repository record for Investigation of the Dosimetric Impact of Patient Immobilization Device and Treatment Couch Structures in Prone Breast Radiation Therapy (opens in a new tab)

  8. VMAT Collimator Angle Optimization

    … the benefits of collimator angle optimization and implement a clinically feasible method to utilize those benefits. Methods: A dosimetric study was planned with first the geometric shapes from TG 119 followed by a patient sample. The final patient sample included five GBM and five esophageal …

    buffalo Repository record for VMAT Collimator Angle Optimization (opens in a new tab)

  9. Development and Testing of a High Resolution PET Detector for Prostate Imaging

    … diagnosis via core needle biopsy is problematic and a game of chance at best. Therefore, in response to new radiopharmaceuticals applicable to both internal and external prostate cancer visualization and localization, novel prostate specific nuclear medical imagers are being developed.;The first …

    wvu Repository record for Development and Testing of a High Resolution PET Detector for Prostate Imaging (opens in a new tab)

  10. MuSun: A Precision Measurement of Nuclear Muon Capture in Deuterium with a Cryogenic Time Projection Chamber

    … fusion, an important input for stellar models, and the neutrino-deuterium breakup reactions required by the Sudbury Neutrino Experiment to quantify the neutrino flux from the sun. MuSun utilizes the lifetime technique -- extracting the capture rate via a comparison of the negatively charged muon …

    washington Repository record for MuSun: A Precision Measurement of Nuclear Muon Capture in Deuterium with a Cryogenic Time Projection Chamber (opens in a new tab)

  11. MEASUREMENT OF LONGITUDINAL SINGLE-SPIN ASYMMETRY FOR W± BOSON PRODUCTION IN POLARIZED PROTON-PROTON COLLISIONS AT STAR AT FORWARD RAPIDITY

    … of the properties of fundamental particles and their interactions. The spin structure of the proton is one of the most challenging open puzzles in Quantum Chromodynamics (QCD). It was believed that the proton spin was carried by the spin of its three valence quarks. However, The results of …

    temple Repository record for MEASUREMENT OF LONGITUDINAL SINGLE-SPIN ASYMMETRY FOR W± BOSON PRODUCTION IN POLARIZED PROTON-PROTON COLLISIONS AT STAR AT FORWARD RAPIDITY (opens in a new tab)

  12. A Study of Magnetic Reconnection: From 2D Energy Release to 3D Spreading and Localization

    … stored magnetic energy is converted into thermal and kinetic energies of the surrounding plasma. Oppositely directed magnetic field lines break and cross connect due to a dissipative mecha- nism. The now bent, reconnected field lines retreat from the X-line (the location of reconnection) at the …

    wvu Repository record for A Study of Magnetic Reconnection: From 2D Energy Release to 3D Spreading and Localization (opens in a new tab)

  13. Deep Learning Applications in Cardiovascular and Neurovascular Intervention

    … are made largely through clinician experience and qualitative inference of two- (and increasingly three-) dimensional image data. This has yielded excellent outcome results, but ignores the vast clinical history which, if utilized, may lead to even better patient outcomes and fewer …

    buffalo Repository record for Deep Learning Applications in Cardiovascular and Neurovascular Intervention (opens in a new tab)

  14. Development of an Image-Guidance System Quality Assurance Program for the Gamma Knife® Icon™ Radiosurgery Treatment System

    … system for tracking patient motion and correcting for inter‐ and intra-fractional shifts, mainly used with thermoplastic immobilization for fractionated and frameless stereotactic radiosurgery Intracranial treatments. This work aims to develop a comprehensive quality assurance …

    buffalo Repository record for Development of an Image-Guidance System Quality Assurance Program for the Gamma Knife® Icon™ Radiosurgery Treatment System (opens in a new tab)

  15. Secondary Monitor Unit Checks for VMAT Using Parallelized Monte Carlo Simulations

    Purpose: To develop a fast and accurate in-house Monte Carlo (MC) based secondary MU check method for independent verification of VMAT treatment planning system dose calculations, that would be in accordance with TG-114 recommendations. Methods: For a VMAT patient treatment plan created for a …

    buffalo Repository record for Secondary Monitor Unit Checks for VMAT Using Parallelized Monte Carlo Simulations (opens in a new tab)

Page 1 of 5