Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 36 for “"occlusion pressure"”.
-
Estimation of limb occlusion pressure by adaptation of oscillometry for surgical tourniquet control
… systems which could regulate the tourniquet pressure just above the limb occlusion pressure (LOP), or the minimum tourniquet pressure required to prevent blood flow past the cuff for a given duration. Previous adaptive tourniquet systems suffered from several problems which limited their …
-
Estimation of limb occlusion pressure for surgical tourniquets based on the measurement of arterial pulse wave transit time
… that these complications are a result of the pressure applied by the tourniquet cuff to the underlying tissue. The use of an adaptive surgical tourniquet system which adapts to maintain the minimum tourniquet pressure required for surgery may allow the use of tourniquet pressures that are on …
-
The use of impedance plethysmography to predict the onset of blood flow beneath a tourniquet cuff
… tissue beneath the tourniquet cuff from the high pressure in the cuff could be minimized with a tourniquet system capable of maintaining the cuff pressure at the occlusion pressure, which is defined to be the minimum pressure that will stop the flow of blood past the cuff. In the work described in …
-
Arterial Blood Flow at Rest and During Exercise with Blood Flow Restriction
PURPOSE: This study comparted arterial occlusion pressure (AOP) of the superficial femoral artery (SFA) between the dominant and nondominant legs and the relationship between blood flow and occlusion pressure at rest and during muscle contractions in males and females. METHODS: The AOP of the SFA …
-
Improved noninvasive determination of blood pressure by oscillometry in the presence of motion artifacts
Blood pressure measurements provide information regarding the status of the cardiovascular system to aid in diagnosing pathological conditions, maintaining patient stability during surgery, and adapting tourniquet pressures. However, the performance of commercially available techniques of measuring …
-
A Cross Validation of the Effects of Leg Size, Limb Composition, and Blood Pressure on Arterial Occlusion in Women Aged 20 to 30 Years
… Previous research has used either arbitrary pressures or a pressure based on systolic blood pressure (1.3 x SBP) to try and individualize the restriction of blood flow to the lower limbs. Recent studies suggest that restrictive pressure should be individualized and based on thigh …
-
Effect of Cuff Pressure on Blood Flow During Blood Flow-Restricted Rest and Exercise
… of this study was to investigate the blood flow/pressure relationship (linear or nonlinear) in the superficial femoral artery when seated, as well as to investigate blood flow changes with exercise using varying cuff pressures and a preexercise (PE) condition. The presence of venous outflow with …
-
The Efficacy of Blood Flow Restriction During High Intensity Resistance Exercise
… flow responses in the lower limbs with varying occlusion pressures, 2) determine the effect of high-intensity BFR (HI-BFR) resistance exercise on fatigue, ratings of perceived exertion (RPE), and pain, and 3) examine the influence of HI-BFR on metabolic stress, muscle damage, and hypoxia. Study …
-
Acute Cardiovascular Response to Low-Load Unilateral, Bilateral, and Alternating Resistance Exercise with Blood Flow Restriction in the Lower Body
… BFR relative to an individual’s arterial occlusion pressure (AOP) and exercising at low-loads seems to produce a comparable cardiovascular response to traditional moderate or high-load training, it is beneficial to identify modifications for reducing the cardiovascular response to BFR …
-
Επίδραση της δεξμεδετομιδίνης στο κυκλοφορικό σύστημα υπό συνθήκες σήψης
… monitoring changes in heart rate, mean blood pressure, central venous pressure, pulmonary artery pressures, pulmonary artery occlusion pressure and cardiac output, pulmonary vascular resistance and central venous oxygen saturation were measured in order to have a complete evaluation of the …
-
Αναπνευστική ενόρμηση, περιορισμός της εκπνευστικής ροής και η συσχέτιση με τη βαρύτητα της νόσου σε ασθενείς με αποφρακτική υπνική άπνοια
… (MFVL), blood gases and measurement of mouth occlusion pressure at the first 100msec of occluded inspiration (P0.1) were obtained at rest. P0.1 was also measured at two different exercise stages. All patients underwent incremental cardiopulmonary exercise testing and flow-volume loops were …
-
A fibre optic based-high resolution manometer with hydrodynamic and contact pressure specificity
Pressure within the esophagus arises from two mechanisms: intrabolus pressure, which is a hydrodynamic phenomenon, and esophageal occlusion pressure, which is a contact phenomenon. Current esophageal manometers are sensitive to both hydrodynamic and contact pressures and cannot distinguish between …
-
The Effects of Blood Flow Restriction and Body Weight Support Treadmill Walking on Electromyographic Activity in Lower Limb Muscles
… conditions at 0% & 50% BWS with and without 80% occlusion pressure of BFR at a self-selected speed. EMG activity was recorded for 30s during each condition. Results revealed that EMG activity was not influenced by an interaction between BWS and BFR for SF (P=.345), RF (P=.845), BF (P=.684), TA …
-
Bilateral upper limb remote ischemic preconditioning improves peak anaerobic power
… condition involved the inflation of blood pressure cuffs to 10 mm Hg. For study 2, the ischemic stimuli were increased to bilateral occlusion while the sham control condition used was 0 mm Hg of occlusion pressure. After the RIPC treatment, subjects completed four 30 s Wingate anaerobic …
-
ACUTE AND CHRONIC RESPONSES TO EXERCISE WITH BLOOD FLOW RESTRICTION
… X-ray absorptiometry to investigate how cuff pressure and as well as the type of exercise alter acute and chronic responses to exercise with BFR. I was the first to report changes in blood flow during resistance exercise with BFR, and before and after aerobic exercise with BFR. Additionally, I …
-
A Comparison of Traditional Blood Flow Restriction Versus Band Tissue Flossing for Induction of Muscular Fatigue
… condition: control (CON), BFR at 50% limb occlusion pressure, and BTF. During each session, participants performed maximal effort leg extension and flexion for 3 sets of 20 repetitions using an isokinetic dynamometer. At the start of each session, baseline heart rate (HR), lactate, glucose, …
-
Monitoring Inspiratory Effort during Synchronous and Dyssynchronous Mechanical Ventilation
… a bench simulation to validate the use of airway occlusion pressure (P0.1) displayed on ventilators to measure respiratory drive (excellent correlation with alternative measures), diagnose low and excessive effort using previous thresholds (AUROC > 0.9), and established the accuracy and precision …
-
The Effects of Different Cuff Widths on Arterial Occlusion in the Upper Body
… widths (5 cm, 10 cm, 12 cm) have on arterial occlusion pressure (AOP) in the arm. A secondary purpose was to determine if arm circumference, blood pressure, arm length, and sex should be accounted for when applying these cuff widths. Two hundred and forty-nine participants visited the …
-
Assessment of Peripheral and Central Hemodynamics During Leg Exercise With "Blood Flow Restriction"
… inflation to 40% of an individual’s arterial occlusion pressure (AOP; cuff pressure which fully occludes limb arterial flow at rest) is assumed to reduce exercising muscle blood flow. However, no study has validated this assumption. Therefore, we sought to determine whether pneumatic cuff …
-
The Effects of High Intensity Isometric Contractions and Low Intensity Isometric Contractions with and without Blood Flow Restriction on Blood Pressure and Discomfort
… blood flow restriction on changes in blood pressure and discomfort. Methods: 179 participants (18-35 years) were randomly assigned to one of four groups. The control group (CON, n=44) only completed the two testing sessions. The training groups completed only one of the following conditions: …