Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 1083 for “"occupant"”.

  1. Occupant-centric building control : balancing occupant comfort and energy efficiency

    … conventionally relies on naive assumptions about occupants, which often leads to occupant dissatisfaction and even more energy waste. Occupant-Centric Building Control (OCC) is a viable solution to mitigate the challenges related to human comfort in building controls. In the OCC approach, the …

    texas Repository record for Occupant-centric building control : balancing occupant comfort and energy efficiency (opens in a new tab)

  2. A simulation-based framework to optimize occupant-centric controls given stochastic occupant behaviour

    Occupant-centric control (OCC) strategies represent a novel approach to indoor climate control in which occupancy patterns and occupant preferences are embedded within control sequences. They aim to improve occupant comfort and energy efficiency by learning and predicting occupant behaviour (OB), …

    concordia Download PDF for A simulation-based framework to optimize occupant-centric controls given stochastic occupant behaviour (opens in a new tab)

  3. OSEM : occupant-specific energy monitoring.

    … The limitation of this approach is that the occupant of a house/building is unaware of his/her energy consumption pattern and has no information regarding how his/her energy-related behavior is affecting the overall energy consumption of a house/building. Energy consumption of a …

    louisville Repository record for OSEM : occupant-specific energy monitoring. (opens in a new tab)

  4. Occupant-Centric Daylight in Housing: Daylight Availability and Occupant Visual Comfort in Seattle Multi-Family Housing

    … therefore, determine daylight availability and occupant visual comfort. The goal to increase daylight availability may conflict with the need to maintain occupant visual comfort, but it is necessary to reach a suitable tradeoff. This study utilizes a simulation-based workflow for incorporating …

    washington Repository record for Occupant-Centric Daylight in Housing: Daylight Availability and Occupant Visual Comfort in Seattle Multi-Family Housing (opens in a new tab)

  5. A Multi-Sensor Passive Occupant Localization

    … a novel IOL methodology that determines occupant positions by analyzing floor vibrations caused by footfall patterns. Unlike traditional localization techniques that rely on visual or radio-based sensing, vibro-localization leverages accelerometers fixed to the floor to capture …

    vt Repository record for A Multi-Sensor Passive Occupant Localization (opens in a new tab)

  6. A comparative study of occupant thermal modeling

    … used to predict the airflow field around the occupant. The correct prediction of the flow field is dependent upon the proper modeling of the occupant body since the actual shape of human body is complicated and its heat distribution is known to be non-uniform. However, past CFD studies on the …

    concordia Download PDF for A comparative study of occupant thermal modeling (opens in a new tab)

  7. Occupant protection design with FE human body models

    The second leading cause of occupant fatalities in traffic accidents are thoracic injuries. Sternal fractures are the most typical moderate thoracic injury in frontal crash. Until now there is no clear understanding about the sternal injury mechanisms and how to minimize the risk of sternal …

    lmu-germany Repository record for Occupant protection design with FE human body models (opens in a new tab)

  8. OCCUPANT-ORIENTED INDOOR ENVIRONMENTAL CONTROLS IN PUBLIC SPACES

    … impacts on the health and comfort of building occupants. In addition, occupant behavior can affect building energy consumption. It is essential to consider actual occupant needs when controlling indoor environmental systems. To provide a healthy, comfortable, and energy-efficient indoor …

    maryland Repository record for OCCUPANT-ORIENTED INDOOR ENVIRONMENTAL CONTROLS IN PUBLIC SPACES (opens in a new tab)

  9. Single-imager occupant detection based on surface reconstruction

    … introduces a novel framework for a real-time occupant detection system capable of extracting both two- and three-dimensional information using a single imager with active illumination. The primary objective of this thesis is to demonstrate the feasibility of such a low-cost classification …

    city-london Download PDF for Single-imager occupant detection based on surface reconstruction (opens in a new tab)

  10. Non-intrusive Occupant Load Monitoring in Commercial Buildings

    … sectors. Promoting energy-saving behaviors among occupants has recently been considered as the most cost-effective approach for reducing commercial building energy consumption, especially for reducing energy consumption of miscellaneous electric loads (MELs) due to direct control of occupants over …

    nebraska Repository record for Non-intrusive Occupant Load Monitoring in Commercial Buildings (opens in a new tab)

  11. Occupant monitoring inside vehicles using FMCW MIMO RADAR

    This thesis presents significant advancements in the field of driver’s chest localization and breathing detection using FMCW radar. It introduces a neural network model for predicting the 3D location of the driver’s chest and a novel algorithm for detecting breathing patterns and localizing the …

    qucosa-diss

  12. Modeling of Occupant Kinematic Response in Pre-crash Maneuvers A simplified human 3D-model for simulation of occupant kinematics in maneuvers - A simplified human 3D-model for simulation of occupant kinematics in maneuvers

    … the intervening evasive maneuvers provoke occupant displacements. Consequently the occupant’s position relative to the restraint systems of the car is affected. Therefore, there is a need to investigate occupant safety also for the pre-crash phase when these evasive maneuvers take place. …

    chalmers Repository record for Modeling of Occupant Kinematic Response in Pre-crash Maneuvers A simplified human 3D-model for simulation of occupant kinematics in maneuvers - A simplified human 3D-model for simulation of occupant kinematics in maneuvers (opens in a new tab)

  13. Qualitative measurements of occupant comfort in five U.S. schools

    … Selected comfort, environmental, physical, and occupant response data were collected in randomly selected areas over a one–week, five–school day monitoring period for each of these schools. The EPA studied indoor air quality (IAQ) and occupant comfort using an EPA Indoor Environmental Quality …

    unlv Repository record for Qualitative measurements of occupant comfort in five U.S. schools (opens in a new tab) Download PDF for Qualitative measurements of occupant comfort in five U.S. schools (opens in a new tab)

  14. Characterisation of particulate matter originating from automotive occupant restraints

    … effluent exposure has focused on vehicle occupants and not occupational exposures and has mainly centred on direct and static measurement of particle mass. This research programme evaluated existing methods of assessment and defined novel methods for more comprehensive characterisation. …

    oxford-brookes Repository record for Characterisation of particulate matter originating from automotive occupant restraints (opens in a new tab) Download PDF for Characterisation of particulate matter originating from automotive occupant restraints (opens in a new tab)

  15. Occupant Merging Behavior During Egress From High Rise Buildings

    Occupant merging behavior on stairwell landings is analyzed through the study of evacuation videos. Both flow rate and transit time analyses are conducted. Data is compared to the hydraulic model, which is presented in Chapter 3 of the SFPE Handbook. It is found that the flow ratio, which is the …

    maryland Repository record for Occupant Merging Behavior During Egress From High Rise Buildings (opens in a new tab)

Page 1 of 55