Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"ocular pulse"”

  1. BIOMECHANICAL RESPONSE OF THE OPTICAL NERVE HEAD TO THE OCULAR PULSE

    … head (ONH) and associated with elevated intraocular pressure (IOP). IOP is not constant but rather dynamic. The ocular pulse refers to the fluctuation of IOP to the heart rate. However, very little is known about the IOP fluctuations in humans and how the eye responds to those fluctuations, …

    nus Repository record for BIOMECHANICAL RESPONSE OF THE OPTICAL NERVE HEAD TO THE OCULAR PULSE (opens in a new tab)

  2. Evaluation of the Effects of Cyclic Ocular Pulse on Conventional Outflow Tissues.

    … constantly exposed to dynamic changes in intraocular pressure (IOP), the effects of such biomechanical stressors on outflow tissue function have not been analyzed. In particular, changes in IOP with each heartbeat have been measured in human eyes approximating 2.7 mmHg/sec. The purpose of this …

    arizona-thes Repository record for Evaluation of the Effects of Cyclic Ocular Pulse on Conventional Outflow Tissues. (opens in a new tab)

  3. Evaluation of Ocular Pulse Amplitude-related Parameters measured by Dynamic Contour Tonometry and Ocular Blood Flow Analyzer

    We performed this study to evaluate ocular rigidity-related factor (ORF) derived from ocular pulse amplitude (OPA) measurements with regard to the severity of glaucoma. This study was conducted in 31 eyes of 31 normal and 38 eyes of 38 normal tension glaucoma (NTG) patients with cross-sectional and …

    ajou Repository record for Evaluation of Ocular Pulse Amplitude-related Parameters measured by Dynamic Contour Tonometry and Ocular Blood Flow Analyzer (opens in a new tab) Embargoed until 9999-12-31

  4. The Impact of Tonometer Measurement Error on Ocular Pulse Amplitude and the Estimation of Pulsatile Ocular Blood Volume

    The complete ocular pressure waveform consists of intraocular pressure (IOP) and ocular pulse amplitude (OPA). IOP is the steady-state component and is related to aqueous humor production and flow in the anterior chamber. OPA is the pulsatile component and drives the arterial pulse pressure, …

    ohiolink Repository record for The Impact of Tonometer Measurement Error on Ocular Pulse Amplitude and the Estimation of Pulsatile Ocular Blood Volume (opens in a new tab)

  5. CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF OPTIC NERVE HEAD IN RESPONSE TO INTRAOCULAR PRESSURE

    … ONH tissue stiffness in human eyes based on the ocular pulse-induced full-field deformations. This project can be divided into two parts: (1) the identification of ONH material properties from the full-field measurements and (2) the measurement of ocular pulse-induced ONH displacements. Three …

    nus Repository record for CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF OPTIC NERVE HEAD IN RESPONSE TO INTRAOCULAR PRESSURE (opens in a new tab)

  6. Οφθαλμική ελαστικότητα και αιματική ροή σε φυσιολογικούς και γλαυκωματικούς οφθαλμούς

    … axial length (AL), as a surrogate parameter for ocular volume, and ocular rigidity (OR), ocular pulse amplitude (OPA) and pulsatile ocular blood flow (POBF). In the second study, we compare OR and outflow facility (C) coefficients in medically treated open angle glaucoma (OAG) patients and …

    greece Repository record for Οφθαλμική ελαστικότητα και αιματική ροή σε φυσιολογικούς και γλαυκωματικούς οφθαλμούς (opens in a new tab)

  7. Heartbeat Optical Coherence Elastography: A Method for Passive Biomechanical Assessment of the Cornea

    … chapter, the need for biomechanical analysis in ocular health and diagnostics and the tools available to perform that task are discussed. The second chapter describes the development of the Hb-OCE technique. Hb-OCE was initially demonstrated in a proof-of-concept ex vivo investigation. The …

    houston Repository record for Heartbeat Optical Coherence Elastography: A Method for Passive Biomechanical Assessment of the Cornea (opens in a new tab)

  8. Biometric and physiological factors in human ocular perfusion

    … thesis addresses three main areas of study: 1. Ocular perfusion features and autoregulatory mechanisms in human myopia; 2. Choroidal thickness at the macular area of myopic eyes; 3. Effect of chronic smoking on the ocular haemodynamics and autoregulation. This thesis demonstrated a reduced …

    aston Repository record for Biometric and physiological factors in human ocular perfusion (opens in a new tab)

  9. Análise comparativa da amplitude do pulso ocular e pressão de perfusão ocular em glaucomatosos, hipertensos oculares e indivíduos normais

    Objectives: To correlate ocular perfusion pressure and ocular pulse amplitude in three different groups: Glaucoma patients, ocular hypertensives, and normal individuals. As well as assess the relation between blood pressure parameters with intraocular pressure. Material and Methods: Ninety patients …

    brazil-ufmg Repository record for Análise comparativa da amplitude do pulso ocular e pressão de perfusão ocular em glaucomatosos, hipertensos oculares e indivíduos normais (opens in a new tab)

  10. Corneal Biomechanical Responses to Intraocular Pressure Using High Frequency Ultrasound Elastography: From Ex Vivo to In Vivo

    … response of the cornea during changes in intraocular pressure (IOP) in both ex vivo donor eyes and in living volunteers.The first two studies presented in this work identify how corneal hydration impacts the mechanical response of postmortem cornea. The 3D strain response of porcine corneas …

    ohiolink Repository record for Corneal Biomechanical Responses to Intraocular Pressure Using High Frequency Ultrasound Elastography: From Ex Vivo to In Vivo (opens in a new tab)

  11. Micro-Viscoelastic Properties of the Human Conventional Outflow Pathway and Their Evolution in an Early Ocular-Hypertension Model.

    … frontal sections of hTM under control and early ocular hypertensive conditions across a broad frequency range (1 Hz-1 kHz). We specifically considered the storage and loss moduli in the ocular pulse-relevant frequency range (1-10 Hz) and their changes across regions under dex treatment for two …

    duke Repository record for Micro-Viscoelastic Properties of the Human Conventional Outflow Pathway and Their Evolution in an Early Ocular-Hypertension Model. (opens in a new tab)

  12. Ultrasound Speckle Tracking Methods to Study the Biomechanical Factors of Ocular Disease

    … of the eye is critical to the maintenance of ocular health and is yet to be fully understood. The primary load-bearing structures of the eye are the cornea, sclera, and optic nerve head (ONH) which together make up the ocular shell. Stresses and strains are generated within these tissues by …

    ohiolink Repository record for Ultrasound Speckle Tracking Methods to Study the Biomechanical Factors of Ocular Disease (opens in a new tab)

  13. Evaluation of a single artery-single junction model for detecting atherosclerotic plaques from blood pressure waveforms

    … of a single stenosis on the arterial pressure pulse are assessed. A 30 cm segment of aorta without branches is modeled with a stenosis of varying parameters located 15 cm from the heart. The aortic pressure pulse serves as input. The effects of the stenosis on the reflected and transmitted peak …

    unh-thes Repository record for Evaluation of a single artery-single junction model for detecting atherosclerotic plaques from blood pressure waveforms (opens in a new tab)

  14. Applications of ex vivo and in vivo ultrasound imaging techniques for the characterization of cornea, retina, sclera, and optic nerve head biomechanics

    … properties of the eye can be directly linked to ocular health and likely play a role in the pathogenesis of ocular diseases and the eventual loss of vision. Altered biomechanics in the corneal stroma at the front of the eye are implicated in the progression of corneal ectasia. Mechanical and …

    ohiolink Repository record for Applications of ex vivo and in vivo ultrasound imaging techniques for the characterization of cornea, retina, sclera, and optic nerve head biomechanics (opens in a new tab)

  15. Ocular biometric investigation of anisometropia

    … regions of the globe to axial expansion.The ocular pulse volume and choroidal blood flow, measured with the Ocular Blood Flow Tonograph, were found to be reduced in myopia; the reductions were found to be significantly correlated with vitreous chamber depth. The thesis includes preliminary …

    aston Repository record for Ocular biometric investigation of anisometropia (opens in a new tab)

  16. Advancing Myopia Research in Children: Evaluating Ocular Rigidity Measurement Repeatability and Optical Biometer Agreement

    Purpose: Ocular rigidity (OR) is a measure of the eye’s distensibility and may be a predictive factor for myopia development and progression in children. Because optical biometers are commonly used to assess ocular parameters related to OR quantification and myopia progression, understanding their …

    houston Repository record for Advancing Myopia Research in Children: Evaluating Ocular Rigidity Measurement Repeatability and Optical Biometer Agreement (opens in a new tab) Embargoed until 2028-05-01

  17. Diagnostischer Stellenwert der okulären Pulsamplitude (OPA) bei Patienten mit stabilem und progredientem Offenwinkelglaukom

    Hintergrund <br>Laut Angaben der deutschen Vertreiberfirma des Dynamischen Konturtonometers (PASCAL®), Technomed, gibt es Hinweise, dass <br>1. anhand der okulären Pulsamplitude (OPA) verschiedene Glaukomformen unterschieden werden können, <br>2. der Index Intraokulardruck (IOD)/okuläre …

    freiburg-diss Repository record for Diagnostischer Stellenwert der okulären Pulsamplitude (OPA) bei Patienten mit stabilem und progredientem Offenwinkelglaukom (opens in a new tab)

Page 1 of 2