Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 47 for “"one storey"”.
-
Non-linear seismic analysis of a one-storey precast concrete building
A non-linear seismic analysis of a one-storey box-type precast concrete building with discrete connections between precast elements is presented. The building is idealized as a single-degree spring-mass-damper system. The inelastic spring represents the total lateral resistance provided by the …
-
2-D non-linear seismic analysis of one-storey eccentric precast concrete buildings
… A 2-dimensional non-linear dynamic analysis of a one storey box-type pre-cast buildings is presented. The shear walls in the buildings are modelled by linear springs, the properties of which depend upon the connections connecting the rigid panels of the shear walls. To check the effectiveness of …
-
The Effects of Diaphragm Flexibility on the Seismic Response of One-Storey Steel Buildings
The response of single-storey buildings to earthquakes is strongly influenced by the flexibility of the diaphragm. Flexibility increases the period of the building, magnifies the ductility demand on the lateral load resisting system (LLRS), and changes the manner in which the inertia forces are …
-
STRUCTURAL SYSTEM FOR WIND AND EARTHQUAKE LOADS
… under sinusoidal, seismic and wind loadings. A one storey and a two storey KBFs with slotted bolted connection were tested using pseudo-dynamic test method. The SBC in the brace was activated based on predetermined slip force. During severe excitation, the knee was brought into inelastic action …
-
Automobilių remonto įmonė "Autostartas", Tilžės g., Šiauliuose /
In this final bachelor work there is designed one-storey special building – car repair center „Autostartas“, where it‘s administrative part of building consists of two stores. Building is designed in industrial district of Siauliai in Tilzes street. Overall area is 5803,63 m2, built-up area is …
-
A distributed-mass model with end-compliance effects for simulation of building pounding
… modes of vibration of floors and (iii) the storey-stiffness of the buildings. The damped Sears model overcomes these limitations by analysing the stress propagation as superposition of viscously damped longitudinal modes of vibration of the floors. The storey-stiffness is incorporated by …
-
Displacement-Based Seismic Design of Timber Structures
… seismic design procedure, applicable to one-storey wooden structures made with a portal system. This typology is very common in Europe and particularly in Italy. A series of analytical expressions have been developed to calculate design parameters. The required analytical Direct-DBD …
-
Postwar Elementary School Design in Ontario
… individual freedom through design. Typically a one-storey brick and steel-framed building characterized by large windows, the postwar school emphasized the physical and emotional well-being of the student through 'child-centred' design that drew primarily from the users' needs. This functional …
-
Καινοτόμα συστήματα δυσκαμψίας και απορρόφησης ενέργειας σε πολυώροφα αντισεισμικά μεταλλικά κτίρια: σχεδιασμός, πειραματική και αναλυτική διερεύνηση
… with horizontal beams also closely positioned. The system is placed at selected positions in the overall structure. Specimens of one storey, at full scale were examined, for the type of cross sections of the connecting horizontal beams, bars or rods and the arrangements for controlled …
-
Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems
… frame, while the SFRS associated with the lower one adopts a traditional structural system, such as reinforced concrete (RC) or structural steel frame. In current practice, the presence of: (a) vertical irregularities on mass and stiffness, and (b) damping difference between lower and upper …
-
Συστήματα περιφερειακής ανάπτυξης: προς μια βιώσιμη περιβαλλοντικά και ενεργειακά θεώρηση της χωρικής ανάπτυξης
… by computerized simulation of a typical one-storey building as well as a multi-storey building. According to the latest spherical approach, the energy efficiency and the cost of the relevant interventions are analyzed using the cost-profit method over the regional and year of …
-
Increasing the seismic resilience of existing reinforced concrete framed structures by using timber-based panels
… with the infills; the activation of soft-storey mechanisms as a consequence of torsional motions or concentration of lateral deformations in a single storey. To reduce the seismic vulnerability of these structures, a retrofit solution was proposed. The solution sees the connection of …
-
Kvalitetsmärkningens betydelse för upplevelsen av innemiljön i småhus
… on the ground foundation, consisted of more than one storey, floor heating on the ground and radiator heating on the upper storey experienced significantly fewer problems with cold floors and drafts than residents in the same non quality labeled single family houses. The house’s heating and …
-
Nouvelle approche de la classification par rigidité des assemblages poutre-colonne en construction métallique
… its displacements. The current criterion mentioned in Eurocode 3, part 1-8, is very approximate. Some joints are therefore classified as semi-rigid or stiffened, which increases their cost, even if they are actually already rigid. The purpose of this work is to define a new, less restrictive …
-
Computer simulation and life cycle analysis of a seasonal thermal storage system in a residential building
… 16 simulation environment. First, a typical one-storey detached house, located in Montreal is considered as a base case. Conventional electric baseboard heaters and an electric domestic hot water storage tank provide the space heating and domestic hot water requirements. A life cycle …
-
Diaphragm stiffness in wood-frame construction
… full-scale diaphragm tests, which has not been done so far for other diaphragm models in previous studies. As such, the model can be used as a “virtual laboratory” to predict the in-plane behaviour of wood-frame diaphragms with various configurations. A simplified model is developed based on the …
-
Development of a prototype tool for the evaluation of the sustainability of Canadian houses
… and optimized during the design process using one of the many available energy analysis tools. Today, building designers must consider as well minimizing the fossil fuel energy use and emissions of greenhouse gases throughout the buildings life cycle. Data, methods, and tools necessary for this …
-
Energy analysis of toplighting strategies for office buildings in Austin
… natural light is a free energy resource. On one hand, a proper design of daylight such as distributed toplights can reduce the electrical lighting consumption. On the other hand, in a hot climate like Austin heat gain is a major concern. Therefore, this thesis is shaped around this question: …
-
Damage identification of unreinforced masonry structures based on vibration response
… undamaged URM panels and an undamaged model of a one-storey URM house. Impacts with a calibrated hammer were used to excite the specimens during the modal test, and also horizontal harmonic excitations in the case of the house model. Two system identification techniques (SSI and FDD) were …
Page 1 of 3