Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 23 for “"one-way slabs"”
-
Rehabilitation of one-way slabs using pre-stressed concrete prisms
… by 9 mm diameter seven-wire strands. Six one-way slabs with dimensions of 3000 mm in length, 600 mm width and depth of 200 mm were cast, then cracked and subsequently rehabilitated with PCPs. Deflected profiles and crack widths of the slabs before and after rehabilitation were compared in …
-
Textile Reinforced Concrete Structures - Bending tests of one-way slabs
… thesis, experiments on carbon fibre reinforced one-way concrete slabs were carried out, to study the flexural behaviour in four-point bending tests. The aim of this Master’s thesis project was to provide data for further development of modelling methods for TRC and give new insights in the …
-
Flexural and Serviceability Behaviour of Steel-GFRP Hybrid Reinforced Concrete Beams and One-way Slabs
… behaviour of steel-GFRP hybrid RC beams and one-way slabs through testing and analyzing 15 RC beams and eight RC one-way slabs. The experimental results were analyzed and compared in terms of the first cracking moment and yielding moment, failure modes, flexural capacity, concrete and rebar …
-
Effect of High-Performance Concrete and Steel Materials on the Blast Performance of Reinforced Concrete One-Way Slabs
… innovative materials in reinforced concrete slabs and panels. As part of the study, a total of fourteen one-way slab specimens with different combinations of concrete, steel fibres and steel reinforcement are tested under simulated blast loads using the University of Ottawa Shock-Tube …
-
Impact of steel ductility on the structural behaviour and strength of RC slabs
… strength and ductility of reinforced concrete slabs. An extensive experimental program examining the ultimate strength, ductility and failure mode of one-way and two-way reinforced concrete slabs is described and the results are presented and analysed. A numerical finite element model is …
-
Strengthening of RC slabs with openings using CFRP systems
… systems in the strengthening of openings in RC slabs. In the study, the concept of strong bands, as indicting a zone for strengthening, was derived first for both one-way and two-way slabs using parametric studies. Thereafter, the required FRP reinforcement was derived for small and large …
-
Fibre reinforced seawater and sea-sand and concrete for marine structures
… developed concrete was used in the casting of one-way slabs reinforced with glass fibre reinforced polymer (GFRP) bars. Flexural test results showed that the combination of GFRP bars with SWSS concrete could be reliably used in the construction of concrete slabs. Adding fibres resulted in a …
-
Study on the shear and punching-shear strength of reinforced concrete slabs subjected to point loads and in-plane tensile forces
… the nature of shear failures in RC beams and slabs, which are typically not provided with shear reinforcement. Despite the exhaustive research work carried out since the beginning of the XXth century, the shear behavior of reinforced concrete elements is still not fully clear. The complex …
-
Σύμμεικτες πλάκες από παραμένοντες τύπους ινοπλεγμάτων σε ανόργανες μήτρες και οπλισμένο σκυρόδεμα: πειραματική διερεύνηση μηχανικής συμπεριφοράς και βέλτιστος σχεδιασμός
… the experimental and analytical investigation of one-way concrete slabs cast over Stay-In-Place formwork elements produced from cementitious composite materials reinforced with textile structures from non-metallic continuous fibers (Textile Reinforced Mortar). In this dissertation the development …
-
Shear in reinforced concrete without transverse reinforcement : from refined experimental measurements to mechanical models
… of structural concrete, the shear behaviour of one-way slabs without transverse reinforcement has been largely investigated. Nevertheless, currently in the scientific community there is no general agreement on the mechanisms of shear failure, on the parameters governing the shear strength and on …
-
Structural behaviour of thick concrete plates
… thick concrete plates are used as structural component in offshore and containment structures for nuclear power generation. An accurate estimate of the minimum steel flexural reinforcement ratio can result in saving millions of dollars for a single project. The recommended concept utilizes the …
-
Service and Ultimate Limit State Flexural Behavior of One-Way Concrete Slabs Reinforced with Corrosion-Resistant Reinforcing Bars
… to traditional black steel. Flexural tests of one-way slabs were conducted to simulate negative transverse flexure over a bridge girder as assumed in the commonly employed strip design method. The bar types studied were Grade 60 (uncoated), epoxy-coated reinforcing (ECR, Grade 60), Enduramet 32 …
-
Studying the Influence of Cracking on The Behaviour of Reinforced Concrete Beams using Distributed Fibre Optic Sensors
… beams and the second three lightly reinforced one-way slabs. All of the specimens were instrumented with distributed fibre optic sensors (DFOS) to measure reinforcement and concrete surface strains. The continuous beams were one degree statically indeterminate and had two asymmetric span …
-
Enhancing Ductility of One-Way Concrete Slabs Reinforced With Welded Wire Reinforcement
… and minimum reinforcement required for WWR slabs. The effect of different types of WWR coating on mechanical properties were investigated. The dissertation next examined the effects of strain rate on the mechanical properties of WWR and traditional rebar. In total, fifty four slabs have been …
-
Durability Study on Concrete Bridge Decks With Pultruded FRP Stay-in-Place Structural Forms
… were thawed without being submerged and one specimen had perforated forms for drainage. Subsequent testing to failure showed no reduction in ultimate capacity or stiffness, despite the 23% reduction in tensile strength of GFRP coupons from the same form, because failure was governed by …
-
A generic mechanics approach for predicting shear strength of reinforced concrete beams.
… and with any bond properties. Moreover, no component of the proposed approach relies on empiricism to account for the mechanics of shear failure, and the approach can accommodate any material characteristics which with time can be refined and revisited to improve the accuracy of shear strength …
-
Strength and Serviceability of Concrete Elements Reinforced with High-Strength Steel
… topics: (i) minimum flexural reinforcement in slabs and walls, (ii) maximum flexural reinforcement in beams, and (iii) crack widths and deflections. Nine slabs with gross longitudinal reinforcement ratio (𝜌𝑔) between 0.07% and 0.18%, four walls with 𝜌𝑔 between 0.07% and 0.24%, and six …
-
Static and Fatigue Shear Strength of Reinforced Concrete Slabs Under Concentrated Loads Near Linear Supports
Reinforced concrete slabs without shear reinforcement under concentrated loads near linear supports are typical cases of bridge deck slabs, transfer slabs or pile caps. Such members are often designed or assessed in shear/punching shear with code provisions calibrated on the basis of tests on beams …
-
Effect of FRP Anchors on the FRP Rehabilitation of Shear Critical RC Beams and Flexure Critical RC Slabs
… techniques and clamps have been explored to postpone and/or delay the debonding process which results in premature failure. FRP anchors are of particular interest because they can be selected to have the same material properties as the FRP sheets that are installed for strengthening or repair of …