Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 155 for “"operating region"”

  1. Algorithm for nonlinear process monitoring and controller performance recovery with an application to semi-autogenous grinding

    … control unit processes over a narrow and linear operating region where the economy of the process is maximized. However, most of these processes are nonlinear outside of this narrow operating region. In the event of a large unmeasured disturbance, a process can shift away from nominal and into an …

    ubc Repository record for Algorithm for nonlinear process monitoring and controller performance recovery with an application to semi-autogenous grinding (opens in a new tab)

  2. Intelligent Adaptive Digital Distance Relaying for High Resistance Earth Faults

    … is also developed. Optimum performance of both operating time and reach accuracy has been obtained. The algorithm, using fast processing techniques, involves reasonable on-line calculation so that a very high sampling frequency can be employed. This thesis will discuss the ideal operating region …

    city-london Repository record for Intelligent Adaptive Digital Distance Relaying for High Resistance Earth Faults (opens in a new tab)

  3. Towards a distributed control regime for robust synchronization and power sharing of inverter-based ac power networks

    … network whose sources are all inverters operating frequency-droop control. By applying graph theoretic methods to the model, I will show that there exists a “safe operating region” of the state space such that if the network angle trajectory stays in this region, then frequency …

    gatech Repository record for Towards a distributed control regime for robust synchronization and power sharing of inverter-based ac power networks (opens in a new tab)

  4. Performance improvement of a proof-mass actuator using nonlinear control

    … implies that the actuator has a finite operating region in terms of initial conditions on the state. This operating region, along with the amount of vibration suppression potential, defines the performance of the actuator. To increase the performance, nonlinear control is proposed. These …

    vt Repository record for Performance improvement of a proof-mass actuator using nonlinear control (opens in a new tab)

  5. Configuration and Performance of Hydraulic Transformer Power Distribution Systems

    … the configuration of the system plays in the operating region and efficiency performance of the power distribution system. The primary tool used in this thesis is a dynamic loss model of a hydraulic transformer. Full mathematical documentation and experimental parameter tuning are described. …

    umn Repository record for Configuration and Performance of Hydraulic Transformer Power Distribution Systems (opens in a new tab)

  6. A Novel Nonlinear PID Controller for Improved Performance and Robust Control of Nonlinear Systems

    … that cause performance compromises and a limited operating region in highly nonlinear industrial systems, which require iterative tuning for each operating region. This process is time-consuming, and the literature indicates that nonlinear PID controllers are a better alternative. However, a …

    liverpool-jm Repository record for A Novel Nonlinear PID Controller for Improved Performance and Robust Control of Nonlinear Systems (opens in a new tab)

  7. Investigation of Modular Multilevel Converter Performance under Non-Ideal Distribution System Conditions

    … supply A novel and simple method for estimating operating region of certain MMC parameters as a function of input variables (grid voltages and power references) is developed. The function of the operating region with respect to key system parameters ensures that the operating region can be …

    south-carolina Repository record for Investigation of Modular Multilevel Converter Performance under Non-Ideal Distribution System Conditions (opens in a new tab)

  8. Analysis of hybrid schedulers for CoMP resource allocation in LTE-Advanced SU-MIMO systems

    … of reference signal strength to determine the operating region for CoMP-JP user selection, and then calculate the robust ratio of RB allocation for CoMP and non-CoMP users. In final stage, the hybrid schedulers adopted specifically for the unique characteristics of CoMP and non-CoMP users will …

    iastate Repository record for Analysis of hybrid schedulers for CoMP resource allocation in LTE-Advanced SU-MIMO systems (opens in a new tab)

  9. Bioartificial livers: theoretical methods to improve and optimize design

    … are subsequently interpreted and presented in Operating Region charts, an image of a parameter space that corresponds to viable BAL designs. These charts allow several important design trends to be identified, e.g. numerous short and thin hollow fibres are favourable over fewer thicker, longer …

    bath Repository record for Bioartificial livers: theoretical methods to improve and optimize design (opens in a new tab)

  10. Characterization and Control of Multi-Cylinder Partially Premixed Combustion

    … control of mixing period was derived. The operating range of multi-cylinder diesel PPC was then evaluated. The study showed that the PPC load range was limited covering only 25% of the operating region for conventional combustion. In order to reach higher loads for PPC the EGR system was …

    lund Repository record for Characterization and Control of Multi-Cylinder Partially Premixed Combustion (opens in a new tab)

  11. A controller design procedure for nonlinear stochastic systems

    … systems are generated at selected points in the operating region. Then a control law which will produce the desired response is developed for each linearized configuration using conventional techniques for linear systems. The resulting control law parameters are treated as tabulated values from a …

    vt Repository record for A controller design procedure for nonlinear stochastic systems (opens in a new tab)

  12. The Low Load Limit of Gasoline Partially Premixed Combustion (PPC) - Experiments in a Light Duty Diesel Engine

    … auto-ignite around top dead center. The limited operating region of HCCI and lack of immediate control actuator, which makes feedback control of the combustion difficult, are two contributing reasons to change focus from HCCI to gasoline Partially Premixed Combustion (PPC). The advantage with …

    lund Repository record for The Low Load Limit of Gasoline Partially Premixed Combustion (PPC) - Experiments in a Light Duty Diesel Engine (opens in a new tab)

  13. Passive UHF RFID tag performance characterization and prediction

    … rate model. The coverage area model predicts operating region of an RFID system and it is found that the operating region is dominated by the downlink turn-on region which is mainly controlled by minimum turn on power of a tag. In the normalized read rate model that predicts the expected read …

    hkust Repository record for Passive UHF RFID tag performance characterization and prediction (opens in a new tab)

  14. A Mean-Squared-Error-Based Methodology for Parameter Ranking and Selection to Obtain Accurate Model Predictions at Key Operating Conditions

    … the ranked list of parameters considering the operating region where accurate model predictions are desired. This new approach accounts for the trade-off between bias and variance as additional parameters from this ranked list are estimated. Next, a new forward-selection methodology based on …

    queens Repository record for A Mean-Squared-Error-Based Methodology for Parameter Ranking and Selection to Obtain Accurate Model Predictions at Key Operating Conditions (opens in a new tab)

  15. Switching linear parameter-varying electronic throttle control for automotive engines

    … throughout the electronic throttle valve's operating region have led to conservative results. In this research, to reduce conservatism, the operating region has been partitioned into smaller subregions. Switching events between subregions are based on the scheduling-parameters of the LPV …

    ubc Repository record for Switching linear parameter-varying electronic throttle control for automotive engines (opens in a new tab)

  16. A goodness of control monitor

    … of the noise often changes, with time and with operating region; so, any practical method must be insensitive to both the noise amplitude and to changes in noise amplitude. This work tries to meet the above requirements.

    ttu Repository record for A goodness of control monitor (opens in a new tab)

  17. System Level Black-Box Models for DC-DC Converters

    … FRFs is linear, it will be valid in a specific operating region defined by the converter operating conditions. Therefore, to satisfy the need for models valid in a wide operating region, a model structure that combines a family of linear two-port models is proposed. One structure, known as the …

    vt Repository record for System Level Black-Box Models for DC-DC Converters (opens in a new tab)

  18. Experimental Evaluation of Solids and Ash Removal Pathways of Fast Pyrolysis Bio-oils

    … a transient rapid and intermediate decline operating region, followed by a pseudo steady-state operating region. It was found that the initial flux of permeate in the transient operating region ranged from 100-1000 L m-2 h-1, while the pseudo steady-state flux ranged from 20-50 L m-2 h-1 for …

    ottawa-retro Repository record for Experimental Evaluation of Solids and Ash Removal Pathways of Fast Pyrolysis Bio-oils (opens in a new tab)

  19. Design and Analysis of New Concept Interior Permanent Magnet Synchronous Motor by 3D Finite Element Analysis

    … has high power density and wide constant power operating region as well as low manufacturing cost. For these purposes, a new concept permanent magnet motor is designed and analyzed with the basic theories about Interior Permanent Magnet Synchronous Motor (IPMSM).</p> <p>This new motor has DC …

    ut-knoxville Repository record for Design and Analysis of New Concept Interior Permanent Magnet Synchronous Motor by 3D Finite Element Analysis (opens in a new tab)

  20. Robust and optimal switching linear parameter-varying control

    … parameter-dependent dynamics variations in its operating region. However, when the dynamics variations are large, LPV control may give the conservative performance. One way to reduce the conservatism is switching LPV (SLPV) control, in which we partition the operating region into sub-regions, …

    ubc Repository record for Robust and optimal switching linear parameter-varying control (opens in a new tab)

Page 1 of 8