Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"optical CT"”.

  1. Iterative image reconstruction for optical CT radiochromic gel dosimetry

    … dose precision to tumors and utilizes hypofractionated treatment regimens. Verifying these dose distributions remains an active research area due to the complexity of delivery systems and the lack of suitable three- dimensional dosimetry tools. Recently, a prototype tabletop solid-tank …

    ubc Repository record for Iterative image reconstruction for optical CT radiochromic gel dosimetry (opens in a new tab) Download PDF for Iterative image reconstruction for optical CT radiochromic gel dosimetry (opens in a new tab)

  2. Application of Optical CT to Estimate the Mass of Macroalgae in a Tank of Water

    … a mass estimation system for macroalgae using optical computed tomography. The system consists of a table with a fixed camera and backlighting, which rotates around a container of macroalgae to collect images from various points. The images capture the translucency along various light paths …

    queens Repository record for Application of Optical CT to Estimate the Mass of Macroalgae in a Tank of Water (opens in a new tab)

  3. Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry

    … dose verification. While they offer a distinct advantage, their application is intricate, requiring specialized expertise for accurate readout. Optical computed tomography (CT) stands out as a primary modality for imaging three-dimensional dosimeters used in validating complex radiotherapy …

    ubc Repository record for Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry (opens in a new tab) Download PDF for Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry (opens in a new tab)

  4. An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions

    … must be validated by measurement to ensure correct patient treatments. Traditional radiotherapy dosimeters do not measure dose entirely in 3D. They effectively ‘spot check’ accuracy at discrete points or planes, without the ability to fully visualise measured dose distributions in true 3D. True …

    adelaide Repository record for An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions (opens in a new tab)

  5. Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner

    … (PAGAT) dosimeter --- using a prototype fan-beam optical computed tomography (CT) scanner. A number of developments sought to improve the performance of the optical CT device. A new fan-creation method (laser diode module) and new matching tank were introduced. Artefact removal techniques were …

    uvic Repository record for Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner (opens in a new tab)

  6. Quantitative 3D Optical Imaging: Applications in Dosimetry and Biophysics

    <p>Optical-CT has been shown to be a potentially useful imaging tool for for the two very different spheres of biologists and radiation therapy physicists, but it has yet to live up to that potential. In radiation therapy, researchers have used optical-CT for the readout of 3D dosimeters, but it is …

    duke Repository record for Quantitative 3D Optical Imaging: Applications in Dosimetry and Biophysics (opens in a new tab)

  7. Modeling and Development of Three-Dimensional Gel Dosimeters

    … gel (PAG) dosimeters to a single spherical radioactive brachytherapy seed. Simulations were conducted for a high dose-rate (HDR) seed using 192Ir and a low dose-rate (LDR) seed using 125I. The model is able to predict the amount of polymer formed, the crosslink density, and the volume fraction of …

    queens Repository record for Modeling and Development of Three-Dimensional Gel Dosimeters (opens in a new tab)

  8. Clinical and Research Applications of 3D Dosimetry

    … radiation oncology medical physics for both effective treatment and patient safety, particularly as innovations in technology allow movement toward advanced treatment techniques that require increasingly higher accuracy in delivery. Comprehensive 3D dosimetry with PRESAGE® 3D dosimeters read out …

    duke Repository record for Clinical and Research Applications of 3D Dosimetry (opens in a new tab)

  9. Investigations in x-ray computed tomography polyacrylamide gel dosimetry

    … information is recorded in the gels and extracted through imaging. X-ray computed tomography (CT) has emerged as a promising gel imaging method due to a change in gel density that occurs upon irradiation. The accessibility of CT technology to cancer hospitals makes CT read-out clinically …

    ubc Repository record for Investigations in x-ray computed tomography polyacrylamide gel dosimetry (opens in a new tab) Download PDF for Investigations in x-ray computed tomography polyacrylamide gel dosimetry (opens in a new tab)

  10. Cone Beam Optical Computed Tomography-Based Gel Dosimetry

    … for the dose delivery. Gel dosimetry is an attractive option for realizing a tissue-equivalent, 3D dose verification tool with high resolution readout capabilities. However, much important work remains to be completed prior to its acceptance in the clinic. The careful development of easily …

    queens Repository record for Cone Beam Optical Computed Tomography-Based Gel Dosimetry (opens in a new tab)

  11. Characterization of The New Xoft Axxent Electronic Brachytherapy Source Using Presage(Tm)

    … advances in the burgeoning field of electronic brachytherapy, an accurate method of 3D dosimetry is needed to ensure understanding of dose distributions, which can improve patient care. The aim of this study was to characterize the Xoft Axxent electronic brachytherapy source using …

    uthsc Repository record for Characterization of The New Xoft Axxent Electronic Brachytherapy Source Using Presage(Tm) (opens in a new tab)

  12. Development of a Novel Readout System for Radiochromic Film Dosimetry

    … However, difficulties overcoming imaging artifacts on these scanners, related to such factors as directional dependence of the film orientation and non-uniform scanner sensitivity, have necessitated the development of strict protocols for film readout and sophisticated image correction …

    queens Repository record for Development of a Novel Readout System for Radiochromic Film Dosimetry (opens in a new tab)

  13. Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide

    … the radiation dose response and ease of manufacture of polymer gel dosimeters that use N-isopropyl acrylamide (NIPAM) as the monomer. An alternative carageenan gelling agent was tested in place of gelatin. Although the carageenan did reduce the gelling time for the dosimeter solution, the dose …

    queens Repository record for Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide (opens in a new tab)

  14. Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters

    … intended calculated dose is being delivered correctly using current techniques that are 2D-based because the resultant dose distributions can differ markedly in various sections of the target. A measurement of composite dose from the entire plan should be included in patient-specific IMRT QA. A …

    uthsc Repository record for Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters (opens in a new tab)

  15. Evaluation of Presage® Dosimeters For Brachytherapy Sources and The 3D Dosimetry and Characterization of The New Agx100 125I Seed Model

    … model (Theragenics Corporation) was then characterized using PRESAGE® following the TG-43 protocol. PRESAGE® dosimeters are solid, polyurethane-based, 3D dosimeters doped with radiochromic leuco dyes that produce a linear optical density response to radiation dose. For this project, the …

    uthsc Repository record for Evaluation of Presage® Dosimeters For Brachytherapy Sources and The 3D Dosimetry and Characterization of The New Agx100 125I Seed Model (opens in a new tab)

  16. Development of a fan-beam optical computed tomography scanner for three-dimensional dosimetry

    The current state of a prototype fan-beam optical computed tomography scanner for three-dimensional radiation dosimetry has been presented. The system uses a helium-neon laser and a line-generating lens for fan-beam creation. Five photodiode arrays form an approximate arc detector array of …

    uvic Repository record for Development of a fan-beam optical computed tomography scanner for three-dimensional dosimetry (opens in a new tab)