Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"optical computed tomography"”.

  1. Cone Beam Optical Computed Tomography-Based Gel Dosimetry

    … careful development of easily accessible, fast optical readout tools such as cone beam optical computed tomography (CT) in combination with stable and reliable low-toxicity gel dosimeters is one key step in this process. In this thesis, the performance capabilities and limitations of the two …

    queens Repository record for Cone Beam Optical Computed Tomography-Based Gel Dosimetry (opens in a new tab)

  2. Design of a solid tank prototype optical computed tomography scanner

    … this work is to design a new prototype fan-beam optical computed tomography (OCT) scanner for three-dimensional radiation dosimetry. Primary distinctions are a solid acrylic tank and the inclusion of iterative reconstruction techniques (IR) into the scanning methods. This scanner attempts to …

    ubc Repository record for Design of a solid tank prototype optical computed tomography scanner (opens in a new tab) Download PDF for Design of a solid tank prototype optical computed tomography scanner (opens in a new tab)

  3. Συνεισφορά της οπτικής τoμογραφίας OCT (optical computed tomography) στην μονοφωτονική τομοσπινθηρογραφία

    … Modern research focuses on the implementation of optical methods in order to gain the morphological image, where scattered light from the area under investigation is properly reconstructed to provide the required anatomical information. The purpose of this Doctoral Thesis is to study an innovative …

    greece Repository record for Συνεισφορά της οπτικής τoμογραφίας OCT (optical computed tomography) στην μονοφωτονική τομοσπινθηρογραφία (opens in a new tab)

  4. Development of a fan-beam optical computed tomography scanner for three-dimensional dosimetry

    The current state of a prototype fan-beam optical computed tomography scanner for three-dimensional radiation dosimetry has been presented. The system uses a helium-neon laser and a line-generating lens for fan-beam creation. Five photodiode arrays form an approximate arc detector array of …

    uvic Repository record for Development of a fan-beam optical computed tomography scanner for three-dimensional dosimetry (opens in a new tab)

  5. Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification

    A prototype rapid, high precision fan beam optical computed tomography (OptCT) scanner for three-dimensional polymer gel dosimetry of complex radiotherapy protocols has been developed. This study documents the design. construction and characterization of the system, as well as preliminary …

    uvic Repository record for Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification (opens in a new tab)

  6. Optimization of optical computed tomography techniques for the synthesis of particle aggregate models

    … combination of 2-D projections. Furthermore, optical tomography methods using the Algebraic Reconstruction Technique (ART) algorithm has proved capable of synthesizing 3-D shapes from 2-D projections, with accuracy comparable to that obtained by an X-ray microtomograph (the "gold" standard). …

    rowan Repository record for Optimization of optical computed tomography techniques for the synthesis of particle aggregate models (opens in a new tab)

  7. An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions

    … for more than 3 decades. Gel dosimetry with optical computed tomography (CT) scanning using visible light wavelengths has been under investigation and development for much of this time. A lack of clinical uptake of the systems developed to date suggests that there are deficiencies or …

    adelaide Repository record for An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions (opens in a new tab)

  8. Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner

    … (PAGAT) dosimeter --- using a prototype fan-beam optical computed tomography (CT) scanner. A number of developments sought to improve the performance of the optical CT device. A new fan-creation method (laser diode module) and new matching tank were introduced. Artefact removal techniques were …

    uvic Repository record for Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner (opens in a new tab)

  9. Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry

    … specialized expertise for accurate readout. Optical computed tomography (CT) stands out as a primary modality for imaging three-dimensional dosimeters used in validating complex radiotherapy treatments. The objectives of this thesis are to (1) develop a ray-tracing simulator capable of …

    ubc Repository record for Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry (opens in a new tab) Download PDF for Fan-beam optical computed tomography using solid tank designs for use in 3D radiation dosimetry (opens in a new tab)

  10. Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography

    … are insufficient. Polymer gel dosimetry with optical computed tomography (OptCT) can be used to measure spatial dose distributions with high resolution. While long experience with MRI has yielded many studies reporting on experiments involving validation of clinical deliveries using polymer …

    queens Repository record for Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography (opens in a new tab)

  11. Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout

    … brachytherapy. Radiochromic gel dosimeters with optical computed tomography (CT) readout would provide such a dosimeter, but the insertion of brachytherapy catheters into the gel cause streak artifacts in the reconstructed dose distributions, ruining the dosimeter’s accuracy. The objective of …

    queens Repository record for Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout (opens in a new tab)

  12. Fabrication of Collagen Scaffolds with Computer Designed Internal Microarchitecture for Blood Vessel Engineering Using Inverse 3D Printing

    … the sacrificial mould is chemically removed, optical computed tomography reveals predefined scaffold microchannel. Immortalized human umbilical vein endothelial cells (HUVEC-hTERT) were seeded in the scaffold microchannels, incubated for 72 hours and assessed for attachment using scanning …

    york Repository record for Fabrication of Collagen Scaffolds with Computer Designed Internal Microarchitecture for Blood Vessel Engineering Using Inverse 3D Printing (opens in a new tab)

  13. Ultrasound-modulated optical tomography for biomedical applications

    I experimentally studied ultrasound-modulated optical tomography, which holds the promise for biomedical diagnosis. I measured the degree of polarization of laser speckles generated by scattered light transmitted through turbid media, investigated three signal-detection schemes for extracting the …

    tamu Repository record for Ultrasound-modulated optical tomography for biomedical applications (opens in a new tab)

  14. Application of Optical CT to Estimate the Mass of Macroalgae in a Tank of Water

    … a mass estimation system for macroalgae using optical computed tomography. The system consists of a table with a fixed camera and backlighting, which rotates around a container of macroalgae to collect images from various points. The images capture the translucency along various light paths …

    queens Repository record for Application of Optical CT to Estimate the Mass of Macroalgae in a Tank of Water (opens in a new tab)

  15. Modeling and Development of Three-Dimensional Gel Dosimeters

    … reporter molecule in micelle gel dosimeters for optical computed tomography (CT) readout. Several gels containing PCDA that was solubilized using sodium dodecyl sulfate (SDS) responded to radiation by changing from colourless to blue. Unfortunately, all phantoms that showed colour changes were …

    queens Repository record for Modeling and Development of Three-Dimensional Gel Dosimeters (opens in a new tab)

  16. Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων

    … gel dosimeter, LCV-Pluronic, coupled with 3D optical computed tomography (OCT) imaging system. EBT3 films were calibrated in air for all beam qualities of a clinical unit (40-220 kVp). These data along with Monte Carlo (MC) simulations facilitated the estimation of both components of EBT3 film …

    greece Repository record for Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων (opens in a new tab)

  17. Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος

    … such as Magnetic Resonance Imaging (MRI), Optical Computed Tomography (CT), x-ray CT and Ultrasound. The appropriate processing of the results for each modality generates a relation between the absorbed dose and the contrast parameter basis of each method. The estimation of the uncertainty …

    greece Repository record for Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος (opens in a new tab)

  18. Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams

    This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and …

    uthsc Repository record for Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams (opens in a new tab)

  19. Τρισδιάστατη απεικόνιση μελαγχρωματικών βλαβών της επιφάνειας του δέρματος με τη χρήση laser και ψηφιακής στερεοσκοπικής φωτογράφησης

    … microscopy), την οπτική τομογραφία συνάφειας (optical coherence tomography), το MelaFind, το SolarScan και το MEDPHOS.Στόχος της παρούσας μελέτης ήταν, σε πρώτο στάδιο, η ανάπτυξη συστημάτων τρισδιάστατης απεικόνισης των μελαγχρωματικών βλαβών του δέρματος, με τη χρήση της Οπτικής Υπολογιστικής …

    greece Repository record for Τρισδιάστατη απεικόνιση μελαγχρωματικών βλαβών της επιφάνειας του δέρματος με τη χρήση laser και ψηφιακής στερεοσκοπικής φωτογράφησης (opens in a new tab)