Optical pyrometry for noncontact temperature measurement
… infrared (IR) transmitting rod and IR lenses to optically measure the temperature of a molten particle as it falls in an evacuated drop tube, has been designed and tested in the laboratory and in the field. The design uses a calcium fluoride (CaF₂) rod which transports optical energy radiated …
-
A STUDY OF THE KINETICS AND THERMODYNAMICS OF LASER IGNITION IN THE COMBUSTION SYNTHESIS OF GROUP IV-B CARBIDES FROM THE ELEMENTS
… Split-frame high speed photography and optical pyrometry were used to obtain kinetic and temperature data on sample heating prior to ignition and during the attainment of self-sustained combustion. From the high speed photography the rate of spread of thermal energy prior to ignition and …
-
Combustion dynamics of individual reactive material particles
… metal powders enabled one to record optical signatures for time-resolved combustion instances for 2-25 um diameter aluminum particles burning in different atmospheres. Individual particle diameters are interpreted and emission signatures are correlated to determine the burn times. The …
-
Reaction Synthesis of HfB2 in a Variety of Metallic Environments
… temperatures and enthalpies of reaction; and optical pyrometry to measure maximum reaction temperatures. Overall, DSC results indicated melting preceded reaction initiation; suggesting that the reaction initiation temperature for a certain blend occurred soon after melt formation, and could be …
-
Experimental study of the equation of state of isochorically heated warm dense matter
… over the _rst 35 ps of expansion by streaked optical pyrometry, and measured the evolution of the target expansion over the same timescale with sub-ps resolution by chirped pulse interferometry. In this way we were able to verify the equation of state and ion-balance in the SESAME equation of …
-
Design and Fabrication of an Infrared Optical Pyrometer Asic as a Diagnostic for Shock Physics Experiments
Optical pyrometry is the sensing of thermal radiation emitted from an object using a photoconductive device to convert photons into electrons, and is an important diagnostic tool in shock physics experiments. Data obtained from an optical pyrometer can be used to generate a blackbody curve of the …
-
Measurement of equation of state of compressed hydrogen and deuterium
… velocity interferometry (VISAR), streaked optical pyrometry (SOP) and x-ray Thomson scattering (XRTS). With a narrow-band x-ray backlighter probe at backscattering geometry the spectrally resolved XRTS accessed the boundary of collective and non-collective regimes making our measurement …
-
Design study into a very high temporal resolution (<10 ps), 2D imaging, modular UV and X-ray diagnostic : the Orion Time Dilation Imager (TIDI)
… parameters. Experimental work to characterise an optical arrangement similar to one which would be used for the UV colour temperature measurements is reported. The optical pyrometry set up was characterised for the Orion target chamber and found to perform as expected. The system provided very …
-
Investigation of high current heaterless hollow cathode ignition
… thermal profile trends through ignition and optical pyrometry has allowed measurements of the emitter tip temperature of an HHC for the first time. The internal cathode-keeper plasma has been investigated using optical emission spectroscopy to determine the plasma electron density.<br/>
-
A study of foam targets for direct-drive inertial confinement fusion
… shock temperature was estimated using streaked optical pyrometry. The results demonstrate that for the pressure range probed in the experiment the TMPTA foam was well described by existing QEOS and SESAME models, suggesting that this foam can be well approximated as a low density homogenous …
-
Self-Diffusion in Single-Crystal Tungsten and Diffusion of Rhenium Tracer in Single-Crystal Tungsten
… concentrator. Temperatures were measured by optical pyrometry, and the system was calibrated by reference to the melting points of tantalum (2996°C), molybdenum (2620°C), niobium (2468°C), and rhodium (1966°C). Sectioning of the diffusion-heated samples was done with a precision surface …
-
Assessment of the temporal release of atomic sodium during a burning black liquor droplet using quantitative planar laser-induced fluorescene (PLIF).
… The second technique, two-dimensional two-colour optical pyrometry, has been adapted to measure the distribution of surface temperature and the swelling (change in surface area) of a burning black liquor droplet. The influence of surface temperature or the change in the external surface area of …
-
Temperature and Radiation Measurements in a Pressurized Oxy-Coal Reactor
… window 1.524 m downstream of the burner. An optical probe focused culminated emission from the combustion chamber into a silica fiber which transported the radiative signal to the spectrometer. The method produced both wall and gas temperatures as well as total integrated intensity. Values …
-
Shock compressing liquids on a tabletop microscope, with special focus on detonating nitromethane
… combination of high-speed diagnostics including optical pyrometry, velocimetry, and high-speed high-resolution imaging were used to monitor the reaction progress of pure NM and NM with additives. After accumulating data on hundreds of NM experiments, it was verified the tabletop shock compression …