Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"orthovoltage"”
-
Monte Carlo Modelling of an Orthovoltage X-ray System Using Multiple Applications in EGSnrc
Biodosimetry relies on calibration curves to convert biological damage induced by ionizing radiation to an absorbed dose. Health Canada generates these curves by irradiating biological samples with X-rays, though exposures scenarios could consist of other types of radiation which are challenging to …
-
Advancing an Open-Source Radiation Treatment Planning System for Orthovoltage X-ray and Cobalt-60 Teletherapy
… algorithms on a patient CT data set. Although orthovoltage x-ray beams remain a simple and effective low-cost treatment modality to treat superficial lesions, their treatment planning remains conventional. Additionally, Cobalt-60 (Co-60) technology continues to be the primary option in some …
-
Monte Carlo study of ion chamber response in low energy photon beams
… by interpolating between 60Co, 137Cs and hard orthovoltage air kerma calibration factors obtained from a standards laboratory. The EGSnrc Monte Carlo package was used to calculate the response in low energy photon beams of a commercial parallel-plate chamber to assess useability as a 192Ir and …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
… field size for 6 different beam qualities in the orthovoltage x-ray range (100 kV tube potential 300 kV). The NE2571 ion chamber, Exradin A16 ion chamber, and Exradin W1 plastic scintillator were considered in this thesis. The last two detectors are not included in the TG-61 protocol.
-
Investigation of the energy response of EBT-2 GAFCHROMIC™ film model
… of 2 Gy to the sensitive layer of the film at orthovoltage energies (50 kVp, 120 kVp, and 180 kVp), 192Ir and 60Co beam. AAPM TG-51 and TG-61 reports were used to determine the dose-to-water and air-kerma in air in megavoltage and orthovoltage beams, respectively, while Monte Carlo simulated …
-
Das langfristige klinische Outcome der Strahlentherapie bei der Behandlung der Plantarfasziitis
… course of RT. Of 396 patients irradiated on orthovoltage devices, 389 received 1.0 Gy (total dose 4.0 Gy), two received 0.5 Gy (total dose 6.0 Gy) and five received more than one series of RT with differing single doses. Three patients were irradiated on a linear accelerator and three were …
-
DEVELOPMENT OF A LOW-DOSE RADIATION THERAPY DEVICE FOR ACUTE RESPRITORY DISTRESS SYNDROME
… affects millions of people a year. The use of orthovoltage (200 – 500 keV) X-ray energy provides many advantages over traditional radiotherapy delivery with linear accelerators, such as low cost and greater accessibility. In addition, X-ray tubes have been shown throughout history to provide …
-
DEVELOPMENT OF A LOW-DOSE RADIATION THERAPY DEVICE FOR ACUTE RESPIRATORY DISTRESS SYNDROME
… illness affects millions of people a year. Using orthovoltage (200 – 500 keV) X-ray energy provides many advantages over traditional radiotherapy delivery with linear accelerators, such as low cost and greater accessibility. In addition, X-ray tubes have been shown throughout history to provide …
-
Dielectric liquid ionization chambers for detecting fast neutrons
… detectors were exposed to 250keV x-rays from an orthovoltage x-ray tube and neutrons (1.4-12MeV) from a 1-Ci 239Pu-Be source. Experimental data show that an ionization chamber filled with dielectric liquid is capable of detecting fast neutrons in pulse mode. While chamber 1, chamber 2, and …
-
Design of an Ytterbium-169 brachytherapy source for gold nanoparticle-aided radiation therapy
… of external x-ray beams from a Philips RT-250 orthovoltage x-ray machine in an attempt to match the dosimetric characteristics of the Ytterbium-169 brachytherapy source. This investigation will enable the production of an external beam that can serve as a good surrogate of an actual …
-
HAFNIUM OXIDE-BASED NANOHETEROSTRUCTURES FOR CATALYTIC RADIOSENSITIZATION AND ENHANCED X-RAY RADIOTHERAPY
Orthovoltage X-ray beams are attractive for surface and intra-operative radiotherapy. Yet, their clinical utility is constrained by rapid attenuation and the limited dose that can be delivered without harming healthy tissue. High-Z hafnium oxide (HfO2) nanoparticles can boost local energy …
-
Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld
… are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; …
-
Development and Commissioning of An Independent Peer Review System For A Small Animal Irradiator
… to characterize other commercially available orthovoltage irradiators.
-
Development of instrumentation and techniques for preclinical image guided microirradiation
… This dosimeter allowed for more accurate orthovoltage beam characterization, thus improving treatment planning and translational treatments.
-
An X-ray Source Model and Characterization Method for Computing kV Radiation Dose
… a conventional CT scanner, superficial/orthovoltage therapy units, and to characterize an in-vivo film dosimetry program in our centre. Our technique is notable for relying only on empirical measurements. It allows a more accurate kV dose computation than treatment planning systems …
-
Nanoliposomes sensibles à la lumière et aux rayons X pour améliorer l'efficacité de la chimiothérapie du cancer du pancréas
… l’encapsulation d’AuDDT. Sous irradiation orthovoltage, ces liposomes ont produit d’importants niveaux de ROS, sans libération du contenu. Au-delà de 0,5 mol %, les formulations étaient instables, mais celles à 10 mol % ont réduit significativement la viabilité tumorale en 3D. La …
-
Investigating the relative biological effectiveness of clinically relevant photon energies and the intrinsic radiosensitivity of human cancer cell lines towards biologically informed radiotherapy treatments
… brachytherapy source, and 225 kVp and 50 kVp orthovoltage x-rays. Cell survival post-irradiation was assessed using clonogenic assays, and survival fractions were fitted using the linear quadratic model. Our findings revealed that cell-killing efficiency increased with decreasing photon …
-
A study on human error, safety culture and risk in radiation oncology
… culture to incidents. This is notable with the Orthovoltage incident in Ottawa, Canada and the incident in Epinal, France. In the study described in this thesis recorded “incidents” were evaluated, with emphasis on where the incident initiated, the type of incident that occurred and the human …
-
Dosimetric Comparison of Superficial X-Rays and a Custom HDR Surface Applicator for the Treatment of Superficial Cancers
The purpose of this study was to design and characterize a custom HDR applicator for the treatment of cancers in the region 0-5 mm, comparing it to the dosimetric properties of the MaximaR-100 superficial x-ray unit. The superficial machine was characterized in terms of percent depth dose, beam …
-
Θεραπεία διαβητικού ποδιού και ακτινικής δερματίτιδας σε καρκίνο του μαστού με εκχυλίσματα Ceratothoa oestroides και Pinus halepensis
… protocol was applied on mice, which received orthovoltage X-rays radiation at the Radiotherapy Department of the Hospital of Dermatology “Andreas Syggros”, Athens, Greece. The total dose of radiation was equivalent to the dose that breast cancer patients receive during radiotherapy. The mice …
Page 1 of 2