Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 73 for “"oscillometric"”.

  1. Advances in oscillometric blood pressure measurement

    … of most automatic cuff devices. We extended the oscillometric principle, which is usedby most automatic cuff devices, to develop a couple of instruments to measure cuff-less BP usinga smartphone-based device and standalone iPhone application. As the user presses her/his fingeragainst the …

    msu

  2. Blood Pressure Estimation Using Oscillometric Pulse Morphology

    This thesis work presents the analysis of Oscillometric blood pressure pulse waveform under different pressure points (Systolic, Mean Arterial, and Diastolic Pressures). Pulse waveforms' characteristics were determined from the waveforms at three different pressures and are compared for subjects at …

    ottawa-retro Repository record for Blood Pressure Estimation Using Oscillometric Pulse Morphology (opens in a new tab)

  3. A Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation

    … pressure (BP) monitors. However, most of the oscillometric algorithms are without physiological and theoretical foundation, and rely on empirically derived coefficients for systolic and diastolic pressure evaluation which affects the reliability of the technique. In this thesis, the …

    ottawa-retro Repository record for A Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation (opens in a new tab)

  4. Determination of Systemic Blood Pressure via Autospectral Analysis of Oscillometric Data

    … but prone to observer-related errors. A new oscillometric method uses sensitive signal conditioning and sensing equipment with a non-invasive arm cuff to record arterial pulsations. The goal of this study is to establish more reliable criteria for the identification of systolic and diastolic …

    portland-state Repository record for Determination of Systemic Blood Pressure via Autospectral Analysis of Oscillometric Data (opens in a new tab)

  5. Improving Algorithms for Oscillometric Blood Pressure Estimation by Suppressing Breathing Effects

    … surveys and assesses the algorithms used for oscillometric blood pressure estimation. Of all the known algorithms, the results of this work revealed one procedure which performed the best. These algorithms were evaluated by readings from two trained nurses. Next, we developed algorithms for …

    ottawa-retro Repository record for Improving Algorithms for Oscillometric Blood Pressure Estimation by Suppressing Breathing Effects (opens in a new tab)

  6. Simplified Model for the Design of an Oscillometric Blood Pressure Measuring System

    The oscillometric method for blood pressure measurement has been known for over a century. It was overshadowed by the classic stethoscope and cuff method until more recently when its ease of automation became useful. It is now found in the automated blood pressure cuffs used in hospitals, doctor's …

    guelph Repository record for Simplified Model for the Design of an Oscillometric Blood Pressure Measuring System (opens in a new tab)

  7. Non-invasive Estimation of Blood Pressure using Harmonic Components of Oscillometric Pulses

    … research presents a pulse-by-pulse analysis of Oscillometric blood pressure waveform at systolic, diastolic and mean arterial pressure points. Using a mathematical optimization technique, pulses are characterized into component harmonic by minimizing the least square error. The results at the …

    ottawa-retro Repository record for Non-invasive Estimation of Blood Pressure using Harmonic Components of Oscillometric Pulses (opens in a new tab)

  8. Validation of oscillometric blood pressure measuring devices : a case study of the BpTRUtm

    … devices of which the majority are of the oscillometric type, are beginning to appear. All new devices have the option of undergoing a validation process to assess the accuracy according to the relevant governing bodies. The BpTRU™ is an automated oscillometric electronic blood pressure …

    ubc Repository record for Validation of oscillometric blood pressure measuring devices : a case study of the BpTRUtm (opens in a new tab) Download PDF for Validation of oscillometric blood pressure measuring devices : a case study of the BpTRUtm (opens in a new tab)

  9. Assessing Arterial Compliance: Utilizing a Surrogate Arm Bench Top Model for Oscillometric Blood Pressure Monitoring

    … replicate physiological conditions to validate oscillometric non-invasive blood pressure measurement methods. The experiment phases included tube, blood pressure cuff, and the surrogate arm compliance tests both in static and dynamic conditions. Tube compliance tests showed that larger diameters …

    calpoly Repository record for Assessing Arterial Compliance: Utilizing a Surrogate Arm Bench Top Model for Oscillometric Blood Pressure Monitoring (opens in a new tab)

  10. Analysis of Arterial Compliance Using a Surrogate Arm Bench Top Model for the Validation of Oscillometric Blood Pressure Methods

    A study was performed on a recently developed prototype of the Yong-Geddes surrogate arm design to collect compliance data of the various system components and determine the accuracy of measurements made through the bench top model. The study was performed to perceive the effectiveness of the model …

    calpoly Repository record for Analysis of Arterial Compliance Using a Surrogate Arm Bench Top Model for the Validation of Oscillometric Blood Pressure Methods (opens in a new tab)

  11. Noninvasive Measurement of Arterial Compliance with a Blood Pressure Cuff Using a Surrogate Arm Bench Top Model for Oscillometric Use

    … that can be used as different inputs for oscillometric testing. A process was established to measure the artery compliances with a curve fit correlation of 0.95. However, testing revealed that this artery compliance relationship might not be an accurate representation of the artery …

    calpoly Repository record for Noninvasive Measurement of Arterial Compliance with a Blood Pressure Cuff Using a Surrogate Arm Bench Top Model for Oscillometric Use (opens in a new tab)

  12. Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation

    … devices, which are usually based on the oscillometric method, do not provide accurate estimation of blood pressure. This problem has been addressed in this work by incorporating arterial stiffness in blood pressure measurement. Pulse transit time is first used to estimate arterial …

    ottawa-retro Repository record for Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation (opens in a new tab)

  13. Παράγοντες που επηρεάζουν την αξιοπιστία της μέτρησης της αρτηριακής πίεσης με ταλαντωσιμετρική τεχνική

    INTRODUCTION: Oscillometric devices are being widely used for ambulatory, home and office blood pressure (BP) measurement and many of them have been successfully validated using established protocols. However, even successfully validated devices fail to provide accurate measurements in some …

    greece Repository record for Παράγοντες που επηρεάζουν την αξιοπιστία της μέτρησης της αρτηριακής πίεσης με ταλαντωσιμετρική τεχνική (opens in a new tab)

  14. Non-Invasive Blood Pressure Measurement Algorithm for All Age Groups

    The oscillometric method is the most common technique used in commercial non-invasive blood pressure monitoring. In this technique, devices record the pressure oscillations in the cuff as the cuff pressure decreases from supra-systolic to sub-diastolic. The values for systolic pressure (SP) and …

    auckland-tech Repository record for Non-Invasive Blood Pressure Measurement Algorithm for All Age Groups (opens in a new tab)

  15. Estimation of limb occlusion pressure by adaptation of oscillometry for surgical tourniquet control

    … practical adaptive tourniquet system. Improved oscillometric LOP estimation performance was obtained through the development of a filter for increasing the signal-to-noise ratio of the oscillometric pulses during periods of limb manipulation, the development of a heuristic real-time pattern …

    ubc Repository record for Estimation of limb occlusion pressure by adaptation of oscillometry for surgical tourniquet control (opens in a new tab) Download PDF for Estimation of limb occlusion pressure by adaptation of oscillometry for surgical tourniquet control (opens in a new tab)

  16. A method comparison study of invasive blood pressure and noninvasive blood pressure measurement in isoflurane-anaesthetized horses performed with Cardiocap™ and the oscillometric device Sentinel

    … blood pressure (NIBP) measured by the oscillometric device Sentinel compared to the invasive blood pressure (IBP) measured by Cardiocap in anaesthetized horses undergoing surgery. To assess if differences between the Sentinel and Cardiocap are associated with recumbency, cuff placement, …

    zurich

  17. Augmented blood pressure measurement through the estimation of physiological blood pressure variability

    … measurement using simultaneous recordings of the oscillometric and continuous arterial pulse waveforms by providing: 1) The mean SBP (or DBP) over the measurement interval, 2) Their respective standard deviations, and 3) An indicator as to whether or not the oscillometric reading is an outlier. …

    ottawa-retro Repository record for Augmented blood pressure measurement through the estimation of physiological blood pressure variability (opens in a new tab)

Page 1 of 4