Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 175 for “"overcurrent"”.
-
Protection system lab experiments with overcurrent and differential relays
… of two ubiquitous protection schemes, overcurrent protection and differential current protection, with the design of experiments and exercises for electrical engineering students. The objective of this undertaking is educational, so that students can learn, understand, and execute …
-
Design and Implementation of Overcurrent Protection Relays Test Bench
… a lab equipment to demonstrate the operation of overcurrent protection relays. It was decided to design the circuit so that it employs equipment removed from the power simulator including microprocessor-based SEL-751A Feeder Protection Relays, Westinghouse CO-8 electromechanical relays, variable …
-
INTELLIGENT METHODS FOR OPTIMUM ONLINE ADAPTIVE COORDINATION OF OVERCURRENT RELAYS
… of existing methods of optimum coordination of overcurrent relays using different optimal techniques. The dissertation outline will be illustrated in the end. Chapter 2 of the dissertation describes a novel method of optimum online adaptive coordination of overcurrent relays using the genetic …
-
Data analytics applications to fault locations and overcurrent protection devices
… with their locations (fault analytics) and (2) overcurrent protection devices installed in the system (device analytics). The fault analytics module is used to identify fault events among other power quality events and estimates the location to the fault occurring in the system. The proposed …
-
Time-domain modeling and validation of overcurrent/reclosing relay operation
The primary goal of this work is to develop a PSCAD/EMTDC simulation model which can emulate the reclosing capabilities of an actual reclosing relay. The first part of this work will demonstrate the capabilities of a commercially available, microprocessor-based reclosing relay, the SEL-551c. Next, …
-
DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY
… to clear a fault from the system. Hence, the overcurrent protection function is incorporated in the scheme. The overcurrent protection of the proposed scheme comprises overcurrent and directional overcurrent relays with earth fault protection. In the case of the directional overcurrent relay, …
-
Application of evolutionary algorithms for optimal directional overcurrent relay coordination
… system network. Optimal relay coordination for overcurrent relays depends on two parameters, namely, Time Multiplier and Pickup Current Setting. The conventional method of setting these two parameters for overcurrent relays applied on the power system network is to first determine the main and …
-
Coordination of time-overcurrent relays for high-speed power line protection
A properly coordinated protection system is essential to ensure that an electricity distribution network can operate within its requirements, regarding the safety of a power system. Automatic operation is necessary to isolate faults on a power system in a minimum time. The study of time …
-
OVERCURRENT RELAYS: MODELLING OF CHARACTERISTICS AND FEASIBILITY OF A COMPUTER BASED DESIGN
Overcurrent relays are used to protect sub-transmission and distribution lines from phase to phase and phase to ground faults. The procedures of determining the settings of these relays include the rule of thumb, template and digital computer methods. The relay characteristics are defined by lookup …
-
THE DESIGN AND IMPLEMENTATION OF A VERSATILE MICROPROCESSOR-BASED DIRECTIONAL OVERCURRENT RELAY
… utilities. With the increasing number of digital overcurrent relays being developed for use in electrical power systems need has arisen for the development of directional relays. In many situations, the magnitudes of fault currents do not provide enough information for correctly discriminating …
-
Assessment Of Overcurrent Relay Coordination In A Microgrid With High PV Penetration Deployment
The existing distribution system is experiencing radical changes with the rapid proliferation of Distributed Energy Resources (DERs)[1]. Microgrids have been proposed as a way of integrating large numbers of distributed renewable energy sources with distribution systems. One of the potential …
-
Optimum coordination of directional overcurrent relays in a distribution network with distributed generation
… used in the industry to calculate the protective overcurrent relay settings. The conventional method requires many inputs and does not produce the best relay coordination results. When there are multiple sources, the calculation process becomes even more complicated and cumbersome. In order to …
-
Active, Controllable Overvoltage and Overcurrent Protection Devices for Power Systems with High Inverter-Based Resource Domination
A rapid proliferation of inverter-based resources that interface distributed renewable energy resources with the bulk power system is currently underway. The changing grid paradigm with more inverter-interfaced resources poses significant challenges to modern power system protection devices. For …
-
A Technique to Utilize Smart Meter Load Information for Adapting Overcurrent Protection for Radial Distribution Systems with Distributed Generations
… BPFs may cause unwanted tripping of existing overcurrent (OC) protection devices and result in permanent outages for a large number of customers. This thesis presents a protection approach that modified an existing overcurrent protection scheme to reduce the number of customers affected by …
-
A New Approach to Mitigate the Impact of Distributed Generation on the Overcurrent Protection Scheme of Radial Distribution Feeders
… feeders is becoming a common trend. The existing Overcurrent Protection (OCP) scheme on such feeders consists mainly of overcurrent protection devices (OCPDs) such as fuses and reclosers. When DG is placed on the remote end of a 3-phase lateral, the radial configuration of the feeder is lost. As a …
-
Investigating overcurrent stresses on 320 kV HVDC cable systems in a VSC-type symmetrical monopolar configuration according to CIGRE guidelines
… bridge Modular Multilevel Converter (MMC) VSC. Overcurrents’ profile (peak value and time duration) caused by di˙erent dis-charging mechanisms and grounding configurations have been analyzed by computer simulations using PSCAD software. Di˙erent types of faults have been simulated, which were …
-
High Power Density and Overcurrent Protection Challenges in the Design of a Three-Phase Voltage Source Inverter for Motor Drive Applications
… designed, built, and tested. In addition a novel overcurrent protection residing in the inverter dc link is proposed in response to the concern of using normally-on devices in voltage source inverters. Successful hardware validation of both the VSI and the overcurrent protection circuit is …
-
Proteção de sobrecorrente direcional utilizando transformada wavelet
… power systems, as distribution systems, is the overcurrent protection due to its simplicity and low cost. However, in these recent years, the number of distributed generation connected to the system has been growing, which changes the complexity of the system and require a directional module to …
Page 1 of 9