Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"oxide free"”.

  1. Electrochemical studies of oxide-free nickel surfaces

    … To verify that the initial metal surface was free of oxide , a surface preparation method was developed , in which a chemical polishing solution was exchanged in-situ by the working solution , while maintaining potential control and oxygen-free conditions. In this way oxide formation from …

    uvic Repository record for Electrochemical studies of oxide-free nickel surfaces (opens in a new tab)

  2. Cryogenic Performance Projections for Ultra-small Oxide-free Vertical-cavity Surface-emitting Lasers

    … 77 K and 4 K operation based on small cavity, oxide-free VCSEL sizes of 2 to 6 µm, that have been shown to operate efficiently at room temperature. Temperature dependent operation for optimally-designed VCSELs are studied by calculating the response of the laser at 77 K and 4 K to estimate …

    ucf Repository record for Cryogenic Performance Projections for Ultra-small Oxide-free Vertical-cavity Surface-emitting Lasers (opens in a new tab)

  3. Electrical Parasitic Bandwidth Limitations of Oxide-Free Lithographic Vertical-Cavity Surface-Emitting Lasers

    … data communications. In the commercial oxide VCSEL technology, an oxide aperture is created inside resonant cavity in realizing good mode and current confinement, however, high electrical resistance comes along with forming the oxide aperture and the electrical parasitic bandwidth …

    ucf Repository record for Electrical Parasitic Bandwidth Limitations of Oxide-Free Lithographic Vertical-Cavity Surface-Emitting Lasers (opens in a new tab)

  4. DESIGN OF BIOCOMPATIBLE ASPARAGINE-GRAPHENE OXIDE FREE CHLORINE SENSORS FABRICATED USING SOLUTION BASED PROCESSING

    … process for a biodegradable electrochemical free chlorine sensor using asparagine that is functionalized onto graphene oxide (GO). An ink solution of the GO functionalized with asparagine was fabricated then deposited onto a screen-printed carbon electrode (SPCE) using a spin-coater. The …

    mcmaster Repository record for DESIGN OF BIOCOMPATIBLE ASPARAGINE-GRAPHENE OXIDE FREE CHLORINE SENSORS FABRICATED USING SOLUTION BASED PROCESSING (opens in a new tab)

  5. Anodic polarisation behaviour of copper in chloride and bromide solutions containing benzotriazole, tolyltriazole, and methylbenzimidazole

    The interactions of oxide free copper surfaces with the organic chemicals benzotriazole, tolyltriazole and methylbenzimidazole were studied in solutions containing sodium chloride to elucidate the effect of modifying the molecular structure of benzotriazole on the inhibition of copper corrosion. …

    ubc Repository record for Anodic polarisation behaviour of copper in chloride and bromide solutions containing benzotriazole, tolyltriazole, and methylbenzimidazole (opens in a new tab) Download PDF for Anodic polarisation behaviour of copper in chloride and bromide solutions containing benzotriazole, tolyltriazole, and methylbenzimidazole (opens in a new tab)

  6. Kinetic studies on the pryolysis of pentenel

    … and by inert gases, but was unaffected by nitric oxide. Free radicals from lead tetraethyl produced an acceleration. The activation energy exhibits a slight increase with increasing initial pressure of pentene. Evidence is presented for a composite reaction mechanism involving both a free-radical …

    ubc Repository record for Kinetic studies on the pryolysis of pentenel (opens in a new tab) Download PDF for Kinetic studies on the pryolysis of pentenel (opens in a new tab)

  7. CO-SOLVENT ASSISTED SPRAY PYROLYSIS FOR THE PREPARATION OF METAL MICROPARTILCE

    … process was used for the generation of various oxide free oxide particles, and the reaction mechanism was shown. In the first part of this study, properties of ultrasonic droplet generator were investigated. Precursor solutions were atomized by a 1.7 MHz ultrasonic nebulizer. The droplet size …

    maryland Repository record for CO-SOLVENT ASSISTED SPRAY PYROLYSIS FOR THE PREPARATION OF METAL MICROPARTILCE (opens in a new tab)

  8. Ion Beam Mixing and Electrocatalysis of Platinum-Iron Alloys

    … A thin film of platinum was evaporated onto an oxide free substrate of iron to form a bi-layer sample. In order to check whether the interface was clean and oxide-free, Auger electron spectrometry was used along with sputtering. The mixing was studied primarily using RBS. The TEM was also used …

    mcmaster Repository record for Ion Beam Mixing and Electrocatalysis of Platinum-Iron Alloys (opens in a new tab)

  9. Chemical and physical aspects of wear processes in polymers

    … studied whilst sliding against mild steel and oxides present on mild steel. The degradation characteristics of P. V. C. and C1d P. V. C. have been correlated in terms of current mechano-chemical comminution theory and the process causing the wear of P. V. C., C1d P. V. C., P. T. F. E. and P. C. …

    brunel Repository record for Chemical and physical aspects of wear processes in polymers (opens in a new tab)

  10. Deposition of Commercially Pure Titanium Powder Using Low Pressure Cold Spray and Pulsed Gas Dynamic Spray for Aerospace Repairs

    … are capable of producing dense, hard and oxide-free coatings using specific parameters. Finally, as a first step towards repair implementation of these processes, damages were simulated on Ti-6Al-4V samples, which were successfully repaired with low porosity and high hardness levels. The …

    ottawa-retro Repository record for Deposition of Commercially Pure Titanium Powder Using Low Pressure Cold Spray and Pulsed Gas Dynamic Spray for Aerospace Repairs (opens in a new tab)

  11. Transient studies at microelectrodes

    … with the advantage of the electrode being oxide free before each data point is recorded.

    soton Download PDF for Transient studies at microelectrodes (opens in a new tab)

  12. Equivalent circuit modeling of TMS plasma polymer coating system on cold-rolled steel

    … Ecoat/ trimethylsilane (TMS) plasma polymer/oxide-free steel surface having an impedance modulus at low frequency of 109 ohms throughout the entire corrosion test. A spray paint primer and surface oxides both contributed to a degradation of corrosion protection evident from a significant drop …

    missouri Repository record for Equivalent circuit modeling of TMS plasma polymer coating system on cold-rolled steel (opens in a new tab)

  13. An X-ray study of the behavior of titanium films on silicon substrates

    … bulk samples at elevated temperatures. The lower free energy monosilicide formed prior to the disilicide in bulk standards and was also the dominant reaction product at lower temperatures in films. Titanium thin films, 2.3 microns thick, sustained considerable mechanical deformation during cooling …

    vt Repository record for An X-ray study of the behavior of titanium films on silicon substrates (opens in a new tab)

  14. Mechanisms of Endothelial Homoglobin Toxicity

    … signal transduction molecules such as nitric oxide. Free Hb also leads to oxidative tissue damage especially on the endothelium: However, the mechanism of this damage was poorly characterized. In the present work, we identified lipid oxidation products as the ultimate toxic reaction species. …

    zurich

  15. Self-heating control of edge emitting and vertical cavity surface emitting lasers

    … continuous wave operation are Joule heating and free carrier absorption loss. To control device self-heating, the epi structure needs to be designed with low electrical resistance and low absorption loss, while the heat flux must spread out of the device efficiently. This dissertation presents …

    ucf Repository record for Self-heating control of edge emitting and vertical cavity surface emitting lasers (opens in a new tab)

  16. Application of pulsed amperometric detection to reversed phase high performance liquid chromatography of some sulfur-containing pesticides

    … preadsorption of the analyte molecules onto the oxide-free electrode surface during cathodic polarization, followed by the oxide-catalyzed oxidation of the adsorbed molecules at anodic detection potential;Amperometric detection in a flow-injection system was achieved using a two-step pulsed …

    iastate Repository record for Application of pulsed amperometric detection to reversed phase high performance liquid chromatography of some sulfur-containing pesticides (opens in a new tab)

  17. Hydrolysis of organophosphorous esters induced by nanostructured titania-based replicas of diatom microshells

    … esters but not that of carboxylic acids in the oxide-free systems. It is believed that fluoride ions act as nucleophilic catalysts to accelerate the hydrolysis of organophosphorous esters. Comparison in the hydrolysis product formation from the two potential hydrolysis pathways (i.e., the P-O …

    gatech Repository record for Hydrolysis of organophosphorous esters induced by nanostructured titania-based replicas of diatom microshells (opens in a new tab)

  18. Lithographic Vertical-cavity Surface-emitting Lasers

    … the introduction of mode- and current-confining oxide optical aperture now used commercially. However, the oxide aperture blocks heat flow inside the device, causing a larger thermal resistance, and the internal strain caused by the oxide can degrade device reliability, also the diffusion process …

    ucf Repository record for Lithographic Vertical-cavity Surface-emitting Lasers (opens in a new tab)

  19. Investigating area selective chemical vapor deposition achieved by competitive adsorption

    … (CVD) of a high dielectric constant metal oxide, Zirconia (ZrO2). High dielectric constant oxides such as Zirconia or Hafnia can replace conventional gate oxides such as silica in future generation CMOS devices. Three types of substrates namely SiO2, Cu, and Co are studied in this thesis. A …

    cornell Repository record for Investigating area selective chemical vapor deposition achieved by competitive adsorption (opens in a new tab)

  20. Study of anomalous behavior in solution synthesized iron nanoparticles

    The magnetic and physical properties of oxide-free, ligand passivated, iron nanoparticles were studied using superconducting quantum interference device (SQUID) magnetometry and synchrotron based X-ray radiation. Particles used for this study ranged in diameter between 2 and 10 nm, which made it …

    texas Repository record for Study of anomalous behavior in solution synthesized iron nanoparticles (opens in a new tab)

Page 1 of 3