Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"oxygen probes"”
-
Performance of brain tissue oxygen probes in vitro under varying physiological conditions
… Currently, the Integra® Licox® brain tissue oxygen monitor is an FDA-approved clinical tool that is used in clinical practice to monitor brain tissue oxygenation (PbtO2) to allow early intervention practices in the patients. The Licox probe is designed as a Clark electrode which measures the …
-
Developing Oxygen-sensitive Probes for Long-term Oxygen Monitoring
Oxygen is important to humans and many diseases either are caused by or result in abnormal contents of oxygen in the human body. Medical treatments are applied to overcome this problem and detecting the oxygen content in the diseased area is necessary to evaluate the efficacy of these clinical …
-
The Development Of Radiofrequency Imaging Techniques And Compact Nmr Systems To Improve Access To Medical Technology
… an R1 relaxometry study was performed on 19F oxygen-probes that were implanted in tissue-engineered grafts. Second, we challenge the conventional use of B1 coils. Traditionally B1 coils are only used for spin tipping. We propose and demonstrate a novel approach that enables B1 coils to not …
-
Optical oxygen sensing based on ruthenium and porphyrin complexes
… design and performance of a ruggedised dissolved oxygen probe, both in the laboratory and in the field, are reported. This probe is based on phase fluorometric detection of the quenched fluorescence of an oxygen-sensitive ruthenium complex. Dissolved oxygen probes have a number of different …
-
Imobilização do complexo cis-Ru(bpy)2Cl2 nas redes orgânicas covalentes RIO para o desenvolvimento de novos fotocatalisadores heterogêneos
… potential was evaluated using singlet oxygen probes and phosphorescence analyses. The results indicated that the composites are not effective photocatalysts for singlet oxygen-mediated reactions. On the other hand, they showed good performance in singleelectron transfer processes. …
-
Thermodynamic properties of Na-Al-O, Ni-Al-O, and Fe-Al-O systems
… of β- and α-AI₂O₃ as solid electrolytes in oxygen probes that can monitor very low oxygen potentials, the chemical stability of β-AI₂O₃ (Na₂O, 11Al₂O₃) was studied by determining the sodium oxide activity in α-AI₂O₃, β-Al₂O₃ coexistence using electrochemical cells of the type</p> <p>Pt⎮W(s), …
-
Development of novel luminescent oxygen sensing platforms for assessing microbial metabolism
Molecular oxygen is a fundamental component in cellular and microbial communities and an important indicator of their health and metabolic activity. Optical nanoparticle-based sensors (nanosensors) possess excellent tunability serving as a promising platform to capture the complex oxygen dynamics …
-
Comparative Studies on Oxygen Mass Transfer for the Design and Development of a Single-Use Fermentor
Accurate experimental oxygen mass transfer coefficient, a measure of how quickly oxygen travels from a gas bubble to the bulk liquid, is important for comparing performance and for evaluating the oxygen transfer capability of a fermentor. Delays in probe response and changing gas volumes upon …
-
Design and Preliminary Measurements Inside a Simplified High Temperature Gas-Cooled Reactor Building
… with several instruments to measure localized oxygen concertation, pressure and temperature with the flexibility for the addition of measurement devices for future testing. The design of the facility required computing the leak rate scaled to the amount of air leaked from the prototype facility …
-
4D EPR Oximetry Imaging for 4D Bioprinting and Tissue Engineering
… is time. Ensuring adequate and consistent oxygen, O2, supply within 3D bioprint volume over the entire maturation period process is crucial, as even transient hypoxia can impact cellular behavior and phenotypes. However, printing of fully developed vasculature remains an unresolved …
-
Novel engineering tools to aid drug discovery processes.
… time) and environmental variables such as oxygen transfer rate, temperature and pH. Ten factors were screened overall at the microwell scale and three were investigated further through optimisation designs. The application of DoE led to a robust understanding of the process and resulted in …
-
Development of particulate-based EPR oximetry for regional, temporal, and rapid measurements in tissue
… addition, the response time of particulate EPR probes was established to be faster than 3.3 ms. Consequently, EPR oximetry was used for measuring temporal oxygen changes in tissue. The study revealed the presence of inherent fluctuations of oxygen in normal and tumor tissue. The frequency of …
-
Fluorescent multiple chemical sensing using time-domain fluorescence lifetime imaging
… allows extracting more information out of probes than fluorescence intensity measurements and it is therefore attractive in order to quantitate multiple species. It leads to better data quality as fluorescence lifetime measurements are not or less affected by many sources of noise in …
-
Conception et réalisation d'un photobioréacteur adapté à l'étude de la production d'hydrogène chez les micro-algues. Application à l'étude de l'influence d'une NAD(P)H déshydrogénase-plastoquinone-réductase chloroplastique de type II sur le potentiel de photoproduction d'hydrogène chez Chlamydomonas reinhardtii.
… on the principle of polarographic analysis of oxygen concentration developed by Leland C. Clark. The O2 and H2 concentrations can be measured by a periodic reversal of the voltage across the electrodes. Finally, a theoretical model of evolution and equilibrium of hydrogen concentration in the …