The photolysis of p-xylene in an aqueous environment
<p>The photolysis of p-xylene in several aqueous solutions was studied as a model for removing refractory organic pollutants from water, and to demonstrate that photochemical reaction of these compounds may be an important factor in their degradation in the environment.</p><p>Solutions of p-xylene …
-
Oxidation of toluene, benzene and p-xylene in a photoreactor
… model compounds, namely, toluene benzene and p-xylene. While toluene and benzene reactions are similar, they are faster with UV/ozone than UV/H<sub>2</sub>O<sub>2</sub> and p-xylene reacts even faster with UV/ozone than UV/H<sub>2</sub>O<sub>2</sub>. The experimental data obtained were analyzed …
-
Cold Active Enzyme Booster Technology (EnBooT) for Biodegradation of P-Xylene
p-xylene is used as a solvent in medical technology, the leather, paint, and rubber industries. The principal pathway of human contact to p-xylene is via soil and groundwater contamination. Bioremediation offers potential advantages such as being cost-effective and environmentally friendly with …
-
A SPRAY REACTOR CONCEPT FOR CATALYTIC OXIDATION OF P-XYLENE TO PRODUCE HIGH-PURITY TEREPHTHALIC ACID
… which the liquid phase, containing dissolved p-xylene (pX) and the catalyst (Co/Mn/Br), is dispersed as fine droplets by a nozzle into a continuous vapor phase containing the oxidant (O2) is shown to produce high-purity TPA with less than 25 ppm 4-carboxybenzaldehyde (4-CBA) in the solid TPA …
-
Application of oxygen microbubbles for in situ biodegradation of p-xylene contaminated ground water in a soil column
In situ biodegradation of p-xylene was studied in a 2.75 inch diameter column using oxygen microbubbles to supply the electron acceptor. One objective was to demonstrate that pxylene can be biodegraded in the soil column and to follow the degradation and pressure drops as a function of time. The …
-
Substrate interactions during the degradation of benzene, toluene, and p-xylene and their effects on sorption in a fixed bed biological activated carbon reactor
Thesis (Ph. D.)--Michigan State University. Department of Civil and Environmental Engineering, 1994
-
Molecular addition compounds :|bI. Systems of p-dioxane with alkyl halides, anisole, and silicon tetrachloride ; II. Titanium tetrachloride chargetransfer complexes of benzene, p-xylene, and pseudocumene
… for titanium tetrachloride systems of benzene, p-xylene, and pseudocumene were detemined. Complexes were shown to be absent from all three systems in the solid state. These data show that previously reported data which indicated a 1:3 complex in the titanium tetrachloride:benzene system are in …
-
A study of the partial oxidation of monosubstituted-p-xylenes
<p>In the oxidation of 2-nitro-p-xylene (I) using alkaline potassium permanganate, the only product isolated was 2-nitro-terephthalic acid (II). Approximately half of the starting material was oxidized. The other half remained as unreacted starting material.</p><p>The chromium trioxide oxidation of …
-
An optimal control strategy for a gas phase bioreactor for the biodegradation of para-xylene
… policy was to biodegrade the maximum amount of p-xylene from the gas stream treated by the reactor within the run time. A bioreactor with a novel design configuration was used to treat a gaseous feed mixture of air and para-xylene. The feed stream is transported radially through an annular sand …
-
Investigation of the three-dimensional structures of zeolite molecular sieves by high resolution solid state NMR
… A highly siliceous zeolite ZSM-5 loaded with p-xylene was chosen for the detailed study. A methodology to investigate the zeolite complexes of highly siliceous ZSM-5 with pxylene molecules by locating the organic molecules inside the framework using only NMR techniques was developed. In this way …
-
Understanding and controlling water-organic co-transport in carbon molecular sieve membranes
… solvent separation. This study focused on p-xylene as an organic contaminant, which is a common aromatic organic solvent encountered in industrial wastewater. Overall, the study sought to understand a structure-transport relationship of water-organic solvent mixture in CMS membranes to …
-
Solid-liquid phase equilibria in systems of (i) para-xylene, (ii) mesitylene, and (iii) N,N-dimethylformamide ; Excess volume determination in systems containing cyclohexane ; Calculations of activities for the n-hexane + cyclohexane system
… compolllld formation in solutions of (i) para-xylene, (ii) mesitylene, and (iii) N,N-dimethyl-formamide (DMF) with mono- and di- halobenzenes that were selected to give a wide range of acceptor properties. Solid 1:1 intermolecular compounds were identified from solutions of p-C_6H_4F_2 with …
-
Biofiltration of BTEX waste gases
… part of the benzene, toluene, ethylbenzene and xylene (BTEX) group, are important solvents and constitutes a large percentage of petroleum. These compounds, mainly due to their solubility as well as being confirmed or suspected carcinogens, have been classified as environmental priority …
-
Biodegradation of Aromatic Hydrocarbons by Methanogenic Consortia and Groundwater-Associated Microbial Communities
… work, the biodegradation of ethylbenzene and p-xylene was examined in the presence of toluene; p-toluic acid was found as a metabolite of p-xylene biotransformation, but no evidence of fumarate addition to either p-xylene or ethylbenzene were observed. A second methanogenic biodegradation study …
-
Production Of Renewable Aromatic Chemicals From Biomass-Derived Furans Through Brønsted Acid Zeolites
… (DMF) and ethylene for the production of p-xylene, and water byproduct, with H-Y and H-BEA zeolite catalysts was investigated. This reaction is completed through a two-step reaction pathway: (1) homogeneous Diels-Alder cycloaddition of ethylene and DMF to form an instable cycloadduct …
-
Investigations into the determination of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) by capillary gas chromatography
… octane, nonane, dodecane, benzene, toluene, p-xylene, o-xylene, and mesitylene. Temperatures of the capillary column, the injection port, the GC/MS interface, the flow rates of carrier gas and make-up gas, and the injection volume were optimized by one factor at a time method or simplex …
-
Purification of Indoor Air Pollutants Utilizing Hydrophobic Adsorbents
… (TCE), benzene, toluene, and para-xylene (p-xylene). In general, these compounds are not present in indoor spaces at acute concentrations, but prolonged exposure to these compounds can have chronic health effects such as allergic sensitization, increased cancer risks, and …
-
The Kinetics, Biochemical Patterns, and Microbial Ecology in Multiredox (Anoxic, Microaerobic, Aerobic) Activated Sludge Systems Treating BTX Containing Wastewater
… reactors. The studies showed that toluene and m-xylene were denitrified via benzoyl-CoA reductase. Although benzene, o-, and p-xylene were recalcitrant under denitrifying conditions, they were biodegraded under microaerobic (< 0.2 mg/L dissolved oxygen) and nitrate or nitrite (NOx)-supplemented …
-
A Study of the Patterns, Stoichiometry, and Kinetics of Microbial BTX Degradation Under Denitrifying Conditions by an Activated Sludge Consortium Receiving a Mixed Waste
… and kinetics of microbial benzene, toluene, p-xylene, m-xylene, and o-xylene degradation by a denitrifying activated sludge consortium was investigated in a sequencing batch reactor (SBR) receiving a mixed waste. After six months of acclimation, toluene and m-xylene were routinely degraded to …
-
High pressure enthalpy of vaporization and vapor pressure for coal based chemicals
… study provides such data for benzene, toluene, p-xylene (BTX) and tetralin. Also the study suggests a new model for the prediction of (AHy)p for other organic compounds. Methods for purification, analysis, instrumentation, and calibration procedures for the instruments used in the measurements and …