Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"p-multiplier"”.
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls at Provo Center Street
… any effect of the wall on the pile resistance (p-multiplier of 1) and the reduction in soil resistance at closer spacings (p-multiplier less than 1). With the addition of the data fro Price (2012) tentative curves have been developed showing p-multiplier vs. normalized spacing behind wall for a …
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls
… the testing have been matched in LPILE using p-multipliers to reduce the lateral resistance. A curve has been developed showing the variation of p-multiplier with normalized pile spacing behind the wall, including data from previous studies. The curve suggests that a p-multiplier of 1 (no …
-
Lateral Resistance of Piles near 15 Foot Vertical MSE Abutment Walls Reinforced with Ribbed Steel Strips
… compare with computed curves from LPILE with p-multiplier developed for the lateral resistance of piles closer to the wall. A curve was created showing the variation of p-multiplier with normalized pile spacing behind the wall. The curve suggests that a p-multiplier of 1 (no reduction in lateral …
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls
… Tentative curves have been developed showing p-multiplier vs. normalized spacing behind wall for a length to height ratio of 1.1 and 1.6. The data suggest that with a L/H ratio of 1.6, a p-multiplier of 1 can be used when the normalized distance from the back face of the MSE wall to the center …
-
Lateral Resistance of Grouped Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements
… in my analysis of the measured test data. The p-multipliers back-calculated with LPILE for the grouped piles were 0.25, 0.60, and 0.25 for the grouped piles spaced at 3.0, 2.8, and 1.8 pile diameters from the wall, respectively. These values are lower than that predicted for piles at the same …
-
Statnamic Lateral Load Testing and Analysis of a Drilled Shaft in Liquefied Sand
… proposed by Rollins et al. (2005) with a p-multiplier of approximately 8 to account for the increased pile diameter. P-y curves based on the undrained strength approach and the p-multiplier approach with values of 0.1 to 0.3 did not match the measured load-deflection curve over the full …
-
Behavior of Batter Piles in Sand
… (3 x 3 and 4 x 4) were examined using the p-multiplier method proposed for the vertical piles. Average values of the p-multipliers appropriate for the small batter pile groups in sand were suggested. Investigations of various pile-to-pile cap connections for the prestressed concrete piles …
-
Numerical investigation of lateral behaviour of a large pile group supporting an LNG tank
… where nonlinear p-y curves are reduced by a p-multiplier to account for the group effects. Alternatively, an average p-multiplier known as a group reduction factor (GRF) can be used. Chapter 1 details the study of using 3D continuum finite element (FE) models to measure the group effects in …
-
Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements
… LPILE software was used to back-calculate P-multipliers that account for the reduced lateral resistance of the pile as a function of normalized spacing from the wall. P-multipliers for this study were 0.95, 0.68, and 0.3 for piles spaced 4.3, 3.4 and 1.8 pile diameters from the wall, …
-
The Influence of Pile Shape and Pile Sleeves on Lateral Load Resistance
… can generally be accounted for using a p-multiplier approach with a value of approximately 1.25 for square or 1.2 for H piles relative to circular piles. It has been determined that high density polyethylene sheeting provides little if any reduction in the lateral resistance when wrapped …
-
Investigation of load transfer models for recycled plastic reinforcement for slope stabilization
… soil present. This model should be used with a p-multiplier selected based on the relative pile batter angle. The soil movement profile should be input as anticipated soil movements down to the sliding depth, and then zero below the sliding depth.
-
Analysis of plates and reinforced concrete columns by cubic b-spline function
… of cubic B-spline function and introduction of p-multiplier in the numerical formulation. Comparison of present analysis with analytical solutions, other numerical methods, and experimental results, appears to have a good agreement.
-
Numerical study on the response of pile groups under lateral loading
… groups is using appropriate factors such as p–multiplier or group reduction factor. The experimental studies on pile groups are usually carried out on small pile groups with close spacings and free-head condition. These limitations are due to the difficulty and high cost of full scale testing …
-
Lateral Resistance of Pipe Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements
… tends to decrease as spacing decreases. P-multipliers for the 3.9, 2.9, 2.8, 1.7D tests were found to be 1.0, 1.0, 1.0, and 0.5, respectively using back-analysis with the computer model LPILE. However, these multipliers are higher than expected based on previous testing and research. Piles …
-
Lateral Resistance of 24-inch Statically Loaded and 12.75-Inch Cyclically Loaded Pipe Piles Near a 20-ft Mechanically Stabilized Earth (MSE) Wall
… software LPILE was used to back-calculate P-multipliers for the 24” piles. P-multipliers are used to indicate the amount of reduction in lateral resistance the piles experience due to their placement near the MSE wall. Previous researchers have proposed that any pile spaced 3.9 pile diameters …
-
Numerical Evaluation of the Lateral Behavior of Vertical and Battered Pile Group Foundations Using 3-D Finite Element Modeling
The design of pile foundations to resist lateral loads is essential in offshore structures and bridge foundations. The lateral behavior of piles has been studied in the past by experimental investigations coupled with analytical and numerical methods. The problem is complex due to the …
-
Full-Scale Lateral Load Test of a 3x5 Pile Group in Sand
… loaded and data were collected to derive p-multipliers. A single pile separate from the 15-pile group was loaded for comparison. Results were compared to those of a similar test in clays. The load resisted by the single pile was greater than the average load resisted by each pile in the pile …
-
Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements
… have a reduction in their lateral resistance. P-multipliers were back-calculated in LPILE from the load-deflection curves obtained from the tests. The p-multipliers were found to be 1.0, 0.85, 0.60, and 0.73 for the H-piles spaced at 4.5, 3.2, 2.5, and 2.2 pile diameters, respectively. The …