  1. Numerical analysis of pile group within moving soils

    … to commonly used p-y and t-z models (p-multipliers, y-multipliers and t-multiplier) are required to produce close matches between the predicted response from MU-PILE-GROUP and measured response from a series of large-scale laboratory tests. The relationship between these multipliers and …

    missouri Repository record for Numerical analysis of pile group within moving soils (opens in a new tab)

  2. Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements

    … have a reduction in their lateral resistance. P-multipliers were back-calculated in LPILE from the load-deflection curves obtained from the tests. The p-multipliers were found to be 1.0, 0.85, 0.60, and 0.73 for the H-piles spaced at 4.5, 3.2, 2.5, and 2.2 pile diameters, respectively. The …

    byu Repository record for Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements (opens in a new tab)

  3. Full Scale Static Lateral Load Test of a 9 Pile Group in Sand

    … sand. Analysis was done in order to determine p-multipliers for the rows in the pile group. The pile group consistently resisted lower average loads than those of the single pile at the same peak deflection. Row 1 resisted equal loads to those resisted by the single pile but Row 2 and Row 3 …

    byu Repository record for Full Scale Static Lateral Load Test of a 9 Pile Group in Sand (opens in a new tab)

  4. Lateral Resistance of 24-inch Statically Loaded and 12.75-Inch Cyclically Loaded Pipe Piles Near a 20-ft Mechanically Stabilized Earth (MSE) Wall

    … software LPILE was used to back-calculate P-multipliers for the 24” piles. P-multipliers are used to indicate the amount of reduction in lateral resistance the piles experience due to their placement near the MSE wall. Previous researchers have proposed that any pile spaced 3.9 pile diameters …

    byu Repository record for Lateral Resistance of 24-inch Statically Loaded and 12.75-Inch Cyclically Loaded Pipe Piles Near a 20-ft Mechanically Stabilized Earth (MSE) Wall (opens in a new tab)

  5. Full-Scale Lateral Load Test of a 3x5 Pile Group in Sand

    … loaded and data were collected to derive p-multipliers. A single pile separate from the 15-pile group was loaded for comparison. Results were compared to those of a similar test in clays. The load resisted by the single pile was greater than the average load resisted by each pile in the pile …

    byu Repository record for Full-Scale Lateral Load Test of a 3x5 Pile Group in Sand (opens in a new tab)

  6. Numerical study on the response of pile groups under lateral loading

    … focuses on group reduction factors and p–multipliers to characterize the group effects in a wide range of pile groups. In order to systematically study the group reduction factors, a numerically derived benchmark database is established using a continuum approach to simulate the response …

    ubc Repository record for Numerical study on the response of pile groups under lateral loading (opens in a new tab)

  7. Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements

    … LPILE software was used to back-calculate P-multipliers that account for the reduced lateral resistance of the pile as a function of normalized spacing from the wall. P-multipliers for this study were 0.95, 0.68, and 0.3 for piles spaced 4.3, 3.4 and 1.8 pile diameters from the wall, …

    byu Repository record for Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements (opens in a new tab)

  8. Lateral Resistance of Grouped Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements

    … in my analysis of the measured test data. The p-multipliers back-calculated with LPILE for the grouped piles were 0.25, 0.60, and 0.25 for the grouped piles spaced at 3.0, 2.8, and 1.8 pile diameters from the wall, respectively. These values are lower than that predicted for piles at the same …

    byu Repository record for Lateral Resistance of Grouped Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements (opens in a new tab)

  9. Behavior of Batter Piles in Sand

    … for the vertical piles. Average values of the p-multipliers appropriate for the small batter pile groups in sand were suggested. Investigations of various pile-to-pile cap connections for the prestressed concrete piles using full-scale static experimental results were performed. On the basis of …

    uiuc Repository record for Behavior of Batter Piles in Sand (opens in a new tab)

  10. SEISMIC AND QUASI-STATIC LATERAL LOAD BEHAVIOR OF PILE GROUPS IN IMPROVED SOFT CLAY: CENTRIFUGE AND NUMERICAL MODELING

    … analyses were performed to back-calculate the p-multipliers. The results revealed that increasing the clay stiffness and pile spacing in the direction of loading increased p-multipliers. The proposed set of p-multipliers for the soft clay is very close to the set suggested by FEMA (Federal …

    oklahoma-thes Repository record for SEISMIC AND QUASI-STATIC LATERAL LOAD BEHAVIOR OF PILE GROUPS IN IMPROVED SOFT CLAY: CENTRIFUGE AND NUMERICAL MODELING (opens in a new tab) Restricted access

  11. Numerical investigation of lateral behaviour of a large pile group supporting an LNG tank

    … the group effects in large pile groups using p-multipliers and GRF. Soil conditions, pile spacing, pile number, and pile head condition were varied to observe their effects. The study also looked at the effect of the circular configuration of pile groups used in LNG tank foundations. The design …

    uvic Repository record for Numerical investigation of lateral behaviour of a large pile group supporting an LNG tank (opens in a new tab)

  12. Influence of Pile Shape on Resistance to Lateral Loading

    … provide agreement with the measured response, p-multipliers of 1.2 and 1.35 were required for the square pile and H piles, respectively. The analyses suggest that the increased resistance for the square and H pile sections was a result of increases in both the side shear and normal stress …

    byu Repository record for Influence of Pile Shape on Resistance to Lateral Loading (opens in a new tab)

  13. Full-Scale-Lateral-Load Test of a 1.2 m Diameter Drilled Shaft in Sand

    … model the drilled shaft response. User-defined p-multipliers were selected to match the measured results with the calculated results. On average very good agreement was obtained between measured and computed response without resorting to p-multipliers greater than 1.0. These results suggest that a …

    byu Repository record for Full-Scale-Lateral-Load Test of a 1.2 m Diameter Drilled Shaft in Sand (opens in a new tab)

  14. Lateral Resistance of Piles Near Vertical MSE Abutment Walls

    … the testing have been matched in LPILE using p-multipliers to reduce the lateral resistance. A curve has been developed showing the variation of p-multiplier with normalized pile spacing behind the wall, including data from previous studies. The curve suggests that a p-multiplier of 1 (no …

    byu Repository record for Lateral Resistance of Piles Near Vertical MSE Abutment Walls (opens in a new tab)

  15. Lateral Resistance of Pipe Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements

    … tends to decrease as spacing decreases. P-multipliers for the 3.9, 2.9, 2.8, 1.7D tests were found to be 1.0, 1.0, 1.0, and 0.5, respectively using back-analysis with the computer model LPILE. However, these multipliers are higher than expected based on previous testing and research. Piles …

    byu Repository record for Lateral Resistance of Pipe Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements (opens in a new tab)

  16. Lateral Resistance of Piles Near Vertical MSE Abutment Walls at Provo Center Street

    … wall respectively. For smaller spacings, the p-multipliers decreased essentially linearly with normalized distance from the wall. A plot showing the increased load in the reinforcement as a function of distance from the pile has been developed. The data in the plot is normalized to the maximum …

    byu Repository record for Lateral Resistance of Piles Near Vertical MSE Abutment Walls at Provo Center Street (opens in a new tab)

  17. Full-Scale Lateral-Load Tests of a 3x5 Pile Group in Soft Clays and Silts

    A series of static lateral load tests were conducted on a group of fifteen piles arranged in a 3x5 pattern. The piles were placed at a center-to-center spacing of 3.92 pile diameters. A single isolated pile was also tested for comparison to the group response. The subsurface profile consisted of …

    byu Repository record for Full-Scale Lateral-Load Tests of a 3x5 Pile Group in Soft Clays and Silts (opens in a new tab)