Optimal Panel Zone Participation in Steel Moment Frames
This work investigates the role of panel zones in the seismic response of buildings using steel moment frames. To address this debated matter requires well-developed finite element models that can accurately simulate the behavior of frame systems under a variety of ground motions. A procedure to …
-
Experimental and analytical investigation of panel zone behavior in steel moment frames
… not yet completely understood: the role of the panel zone. Recent U.S. building codes have significantly increased the required shear strength of the panel zone for seismic applications. This leads to increased column sizes or the need for costly doubler plates. A number of past research studies …
-
Characterization of the Full Non-Linear Behaviour up to Failure of the Sheared Panel Zone under Monotonic Loading Conditions
… this project and focuses on the behaviour of the panel zone (PZ), which is known to provide a significant reserve of ductility to the joint, when activated and appropriately designed. The main objective of the thesis thereby consists in providing a new sophisticated analytical model, which can …
-
Preliminary analysis of doubler plate attachment details for steel moment resisting frames
… within the beam-column joint is known as the panel zone. When a steel moment resisting frame is subjected to lateral load, due to wind or seismic loads, the panel zone is subject to high shear. In some cases, the shear in the panel zone is sufficiently high that the panel zone must be …
-
Finite element analysis of doubler plate attachment details and load paths in continuity plates for steel moment frames
… improved understanding of the behavior of column panel zones reinforced with doubler plates in seismic resistant steel moment frames. A primary goal of the research was to develop data to support the development of improved design guidelines for welding doubler plates to columns, with and without …
-
Cyclic loading analysis of doubler plate attachment details for steel moment resisting frames
The panel zone region in columns of seismic resistant steel moment frames are subject to very high shear forces during earthquake loading. Doubler plates are often used to increase the stiffness and strength of the panel zone. The methods and details used to attach doubler plates to columns can …
-
Finite element analysis of welds attaching short doubler plates in steel moment resisting frames
… studies have investigated the performance of panel zones in seismic-resistant steel Special Moment Resisting Frames (SMF). These recent studies investigated various options for attaching doubler plates to the column at beam-column joints in SMF for purpose of increasing the shear strength of …
-
Extended end-plate beam-column joints in seismic moment resisting frames
… were done to study the response of panel zones of this joint type. Based on the observation and results of the experimental program, analytical models to predict the behaviour of both the connection and the panel zone were developed. The sensitivity of these models was checked by …
-
Computational Fracture Prediction in Steel Moment Frame Structures with the Application of Artificial Neural Networks
… problem remains unresolved: the degree of panel zone participation that should be permitted in the inelastic seismic response of a steel moment frame. To date, a fundamental computational model has yet to be developed to assess the cyclic rupture performance of moment frames. Without such a …
-
Performance Prediction and Evaluation of Steel Special Moment Frames for Seismic Loads
… effect of post-Northridge ductile connection, panel zone deformation and interior gravity frames. The 1973 UBC, 1985 UBC and 1994 UBC provisions were selected for the pre-Northridge 3-, 9- and 20-story buildings in Los Angeles and Seattle and designed for wind and seismic loads. A total of 15 …
-
Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών πλαισίων με ιδιομορφικούς συντελεστές συμπεριφοράς και τρεις στάθμες επιτελεστικότητας
… frames including the contribution of the panel - zone and steel frames with buckling restrained braces. The steel frames are subjected to far - field seismic ground records corresponding in the 4 soil classes A,B,C and D of the Eurocode 8. The seismic records have been scaled properly in …
-
Prediction of cracking in steel joint subjected to high cyclic strains
… more highly stressed area in the connections "panel zone" did not crack in the experiments, perhaps because of the more complex stress field and defect orientation to the tensile stresses in this location. The connection was improved by adding triangular bracing gussets, in the plane of the …
-
Finite element analysis of steel moment frame joints with doubler plates and continuity plates
… of a finite element study of the behavior of the panel zone region in beam-column joints in seismic resistant steel moment frames, with a focus on the interaction between continuity plates and extended doubler plates. Several recent studies have examined this same issue, but utilized a simplified …
-
Behaviour of steel and steel-concrete composite beams and beam-to-column connections at elevated temperatures
… the mechanics of this potential failure zone in the column web in the compression region of the connection is a useful and needed addition to research in the topic. Predicting the critical temperature in a connection that causes failure of the bolts, end plate and column flange in the …
-
Evaluation of the seismic level of protection of steel moment resisting frame building structures
… strong-beam (WCSB), and strong-column weak-panel zone (SCWP). The scope of the research program includes: (a) modelling of the structural elements; (b) nonlinear push over static analyses/inelastic dynamic analyses, and (c) evaluation of the damage potential associated with each design. In …
-
Seismic strengthening of deficient exterior RC beam-column sub-assemblages using post-tensioned metal strips
… and damage including a shear mechanism in the panel zone. The joints failed prematurely at about 50% of their nominal flexural strength. Strengthening the joints with post-tensioned metal strips led to an improved performance, higher energy dissipation and more controlled shear failure along …
-
Peak Connection Strength of Reduced Beam Section Moment Frame Connections
… of 𝐶𝑝𝑟 may lead to undesirable behaviors such as panel zone yielding, column kinking, reduced energy dissipation, and potential fracture at beam-to-column welds. Design implications of adopting the proposed 𝐶𝑝𝑟 values include the disqualification of certain beams for shorter bay lengths under the …
-
Cyclic Testing of a Skewed Special Moment Frame RBS Connection Having a Composite Concrete Slab
… the inter-story drift. Additionally, column panel-zone yielding and column flange yielding were observed. Local strain measurements within the RBS and beam-to-column connection regions suggest relatively similar demands across the RBS but with higher demands at the edges (similar to …
-
Seismic Response of a Full-scale 5-story Steel Frame Building Isolated by Triple Pendulum Bearings under 3D Excitations
… connection were modeled using a Krawinkler panel zone model, and (3) energy dissipation was represented by Rayleigh damping calibrated to include higher mode effects observed in the test data, along with additional interstory dampers. The vertical component of the excitation was shown to …