NOVEL PARALLEL TRANSMIT SYSTEMS FOR MRI APPLICATIONS
In this work a new RF transmitter design is presented for MRI parallel transmissionapplications. Benchtop measurements and imaging experiments were performed withdifferent prototypes to prove system’s performance and potential advantages versus asystem based on conventional MRI RF hardware. The …
-
Isolating Power Amplifiers for Parallel Transmit MRI
A radio frequency parallel transmitter was developed for magnetic resonance imaging. Eight channels of vector modulation and isolating power amplifiers were constructed so that the performance of different amplifier architectures could be investigated. An eight channel system was implemented and …
-
Slice-selective parallel transmit magnetic resonance imaging at 7T
… produces signal dropouts and contrast losses. Parallel transmission (pTx) technology, employing multiple transmit channels to dynamically control RF pulses, is a promising solution to overcome these limitations. While pTx has shown maturity in 3D neuroimaging with universal pulses, its …
-
Radiofrequency safety modelling of parallel transmit magnetic resonance imaging
… (PRF) based MR thermometry in the context of parallel transmit (pTx) MRI is described in Chapter 4. Also described in this chapter is a 3D gradient-echo sequence used to monitor temperature-induced phase shifts, as well as the required image reconstruction techniques and field-stabilisation …
-
Parallel transmit pulse sequence design for ultra-high field (7T) MRI
… solution to improve image homogeneity is parallel transmission (pTx). A pTx-enabled scanner has multiple independently-driven transmit channels, providing additional degrees of freedom for improved spatial and temporal control of the B+1 fields. This thesis aims to extend the methodology …
-
Eight-Channel Head Array and Control System for Parallel Transmit/Receive Magnetic Resonance Imaging
… wavelength causes potential inhomogeneity in the transmit field of the RF coil, resulting in non-uniform excitations. Susceptibility effects are also more pronounced at high field strengths, and can cause local distortions in the field and create areas of signal dropout. Parallel transmit is one …
-
Motion estimation using radiofrequency scattering of a parallel transmit coil for cardiac magnetic resonance imaging at 7T
… are based on radiofrequency (RF) scattering of a parallel-transmit coil and directly assess the heart motion, independent of the electrical activity of the heart. A cardiac motion signal is derived with a high SNR and with a number of potential gating features, which have a high accuracy when …
-
Quantitative Evaluation of Microstrip, Dipole and L/C Loop Parallel Transmit (pTx) Arrays for UHF MR Imaging
… in depicting soft tissue pathologies, offering unparalleled detail for clinical diagnosis and biomedical research. Radiofrequency coil arrays enhance sensitivity, scan speed, and image consistency across the brain to optimize performance further. Advanced UHF scanners are equipped with 8 or 16 …
-
New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI
… design an eight-channel array coil that is both transmit and receive, and could be used for both types of studies. We focused on optimizing the array for the application of small field-of-view (FOV) excitation, which allows zooming into a region-of-interest (ROI). For example, in breast imaging …
-
Parallel transmission technologies for imaging the brain and body with 7 tesla MRI
… field non-uniformity using technology known as parallel transmission. Although, in order to provide a robust subject-specific improvement the non-uniform radiofrequency field must first be mapped in a process known as “B1+ mapping”.</p> <p>To begin, I will go through some essential magnetic …
-
Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla
… which includes field strengths of 7T and above. Transmit B +1 field inhomogeneity is also higher, causing uneven signal intensity and linking to an uneven SAR distribution, which is also higher than at lower field strengths. The potential for higher spatial resolution imaging can also result in …
-
Multi-rate access schemes and successive interference cancellation for wireless multimedia MC-CDMA communications
… such as voice, video and higher rate data can be transmitted seanilessly through one MC-CDMA infrastructure. The performance of the multi-rate MC-CDMA is mainly limited by multiple access interference (MAI). For example, in the MFSL MC-CDMA systems, the interference is not only presented among …
-
Investigation of a remote 32-channel whole-body coil for large field of view 1H body imaging at 7 T
… coils and to experimentally investigate the parallel transmit (pTx) capabilities of the remote coil through in-vivo measurements. The thesis was divided into two parts. First, the transmit and receive performance of seven different local pTx coils and the remote coil (also in combination with …
-
Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging
… of imaging at such extreme field strength is the transmit B1 field inhomogeneity. The technique of parallel transmission has been proposed to mitigate such challenge and provides opportunities to explore new acquisition methods. To take advantage of these capabilities, this thesis investigates its …
-
Parallel transit methods for arterial spin labelling magnetic resonance imaging
… arteries in the neck. It is proposed to combine parallel transmission (multiple transmit coils, each transmitting with different amplitudes and phases) to spatially tailor the labelling field, removing the reliance on coil location for optimal labelling efficiency, and enabling robust vessel …
-
APPLICATIONS OF GALLIUM NITRIDE FETS TO RF ARRAYS FOR MAGNETIC RESONANCE IMAGING
… primary subsystems of an MRI scanner are the RF transmit and receive chains, containing coils, switches, and amplifiers. The RF chains’ fundamental architecture has changed little since its inception, with Silicon transistors dominating the roles of switches and amplifiers.Recent trends have …
-
Ultra-high field (7T) magnetic resonance fingerprinting
… Chapter 10 describes my work to understand the parallel transmit framework on our new 7T Terra scanner, culminating in a successful human in vivo liver scan utilizing an 8-channel body transmit array coil. Overall, I have implemented key steps towards a viable 7T MRF sequence for human in vivo …
-
A 64 Channel Transmit System for Single Echo Acquisition MRI
… based methods have reached the safety limit. Parallel receiving techniques achieve accelerations by reducing phase encoding steps. Among these methods, SEA Imaging achieved the highest possible acceleration by completely eliminating phase encoding. However, SEA imaging is limited to thin …
-
Control System for Phase-Only B1 Steering in High Field Magnetic Resonance Imaging
… requires the ability to change phase for transmit power (TX) on each channel of a parallel transmit coil. While a simple approach to this problem would be to use a collection of coaxial cables of various lengths, this is very cumbersome and limits the functionality of the system. …
-
High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI
… and B0 inhomogeneity and higher SAR deposition. Parallel transmit (PTx) combined with more advanced pulse design methods is a flexible solution to overcome B+1 inhomogeneity. During my PhD I investigated how to compare different qMRI methods and developed two RF pulse design methods for pTx …