Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"parapet"”.

  1. Placements Guidelines for Bridge Parapet Systems with Curbed Sidewalks

    … regarding the safety performance of bridge parapet systems without curbs in the last few decades. However, since curbs are often necessary for certain reasons such as drainage, right-of-way reduction, or other functions, more research including curbs is necessary. Thus, this study focuses on …

    tamu Repository record for Placements Guidelines for Bridge Parapet Systems with Curbed Sidewalks (opens in a new tab)

  2. Yield line analysis of an AASHTO New Jersey concrete parapet wall

    … line analysis for a constant thickness concrete parapet wall. The purpose of this study is to develop similar equations for R<sub>w</sub> and L<sub>c</sub> based on yield line analysis of a variable thickness New Jersey concrete parapet wall instead of a constant thickness wall. The results from …

    vt Repository record for Yield line analysis of an AASHTO New Jersey concrete parapet wall (opens in a new tab)

  3. The effects of parapet walls on roof pressures measured in full scale

    … to acquire wind and roof pressured data behind a parapet wall. The objectives of this study were to obtain reliable data for the external pressures on the buildings surface and internal pressures in the building and to determine how the parapet wall affects the roof pressures. A partial parapet …

    ttu Repository record for The effects of parapet walls on roof pressures measured in full scale (opens in a new tab)

  4. Comprehensive study of wind loads on parapets

    … local (components and cladding) wind loads on parapets. For the first time, it was attempted to measure such loads in full-scale, in order to address the issues encountered in previous wind tunnel studies. Field testing was carried out using the full-scale experimental building (3.97 m long, …

    concordia Download PDF for Comprehensive study of wind loads on parapets (opens in a new tab)

  5. Below the parapet: a phenomenological exploration of adult inter-personal relationships for individuals who grew up with a sibling with a severe mental illness

    Siblings of those with severe mental health illness (SMI) have long been overlooked in research and, what interest there has been, seems to have been borne out of the desire to establish how best to engage them in providing care and support for their mentally ill brother or sister when their …

    middlesex Download PDF for Below the parapet: a phenomenological exploration of adult inter-personal relationships for individuals who grew up with a sibling with a severe mental illness (opens in a new tab)

  6. Wind-Induced Gravel Blow-Off: Experimental Investigations and Predictive Modeling for Resilient Roof Design

    … Irwin probes. Measurements were taken for seven parapet heights and nine wind angles. The collected pressure data aligned well with previously published data for similar building geometries, confirming the reliability of the Irwin probes, even in highly separated flow conditions. Classic V-shaped …

    clemson Repository record for Wind-Induced Gravel Blow-Off: Experimental Investigations and Predictive Modeling for Resilient Roof Design (opens in a new tab)

  7. PREDICTING WIND PRESSURE ON LOWRISE BUILDINGS WITH PROTECTIVE PARAPETS USING ARTIFICIAL NEURAL NETWORKS

    … pressure on low-rise buildings with protective parapets. With existing experimental datasets conducted in BLWT, ANN models were trained to model non-linear relationship between inputs, such as tap coordinates and parapet height, and outputs, such as pressure coefficients. The developed model was …

    maryland Repository record for PREDICTING WIND PRESSURE ON LOWRISE BUILDINGS WITH PROTECTIVE PARAPETS USING ARTIFICIAL NEURAL NETWORKS (opens in a new tab)

  8. Quantifying unreinforced masonry seismic risk and mitigation options in Victoria, BC

    … Upgrading measures considered range from parapet bracing to full seismic upgrades consistent with local practices. Parapet bracing is shown to have favorable cost-benefit ratios – up to 4:1 for buildings on soft soils, indicating that the expected benefits outweigh the costs by a factor of …

    ubc Repository record for Quantifying unreinforced masonry seismic risk and mitigation options in Victoria, BC (opens in a new tab) Download PDF for Quantifying unreinforced masonry seismic risk and mitigation options in Victoria, BC (opens in a new tab)

  9. Full-scale study of wind loads on a flat roof with parapets

    … have been carried out to examine the effect of parapets on roof wind loading. Most of these studies have been carried out in the wind tunnel and rarely has an effort been made to study this effect in full-scale. A systematic and extensive research has been carried out in the present study to …

    concordia Download PDF for Full-scale study of wind loads on a flat roof with parapets (opens in a new tab)

  10. An Experimental and Computational Study of Windborne Debris in Severe Storms

    … number versus Reynolds number for different parapet heights are presented. The results indicate that the current approach for scaling result from laboratory to full scale is flawed and that full scale experiments are required to fully understand this process. The rate of removal, or mass …

    clemson Repository record for An Experimental and Computational Study of Windborne Debris in Severe Storms (opens in a new tab)

  11. A cyber-physical approach to the optimal design of civil structures using boundary layer wind tunnels and mechatronic models

    … was developed to optimally design the parapet wall of a low-rise building. Parapet walls nominally reduce suction loads on the roof but lead to an increase in positive roof pressure and base shear. A mechatronic low-rise building model was created with a parapet wall of adjustable …

    maryland Repository record for A cyber-physical approach to the optimal design of civil structures using boundary layer wind tunnels and mechatronic models (opens in a new tab)

  12. Investigation of the Mechanical Response of Monolithic Shearwalls with Openings

    … and mechanical properties of lintel beams and parapets on the stiffness and strength of multi-storey CLT shearwalls with symmetric door or window openings. The influence of construction techniques, where the opening is cut out of the panel or constructed using separate elements is investigated. …

    ottawa-retro Repository record for Investigation of the Mechanical Response of Monolithic Shearwalls with Openings (opens in a new tab)

  13. Experimental study of wind induced suction on flat roofs.

    … full building test results as long as the parapet height ratio is kept constant and the wind tunnel blockage ratio is kept minimal.

    ottawa-retro Repository record for Experimental study of wind induced suction on flat roofs. (opens in a new tab)

  14. Experimental investigations of anchorage capacity of precast concrete bridge barrier for Performance Level 2

    … In particular, the anchorage capacity of the parapet under the CHBDC design load warrants verification. A finite element model of the barrier was developed in ANSYS to study its structural response. Static testing of a set of barriers was carried out at the University of British Columbia to …

    ubc Repository record for Experimental investigations of anchorage capacity of precast concrete bridge barrier for Performance Level 2 (opens in a new tab) Download PDF for Experimental investigations of anchorage capacity of precast concrete bridge barrier for Performance Level 2 (opens in a new tab)

  15. Effects of Parapets on the Performance of Unglazed Solar Collectors

    … Studies have demonstrated that perimetric parapets can modify wind loads on roofs and the structural support system of solar panels and collectors. Insufficient attention has been devoted to examining the influence of parapets on collector heat loss, as well as the optimal placement of …

    auckland-tech Repository record for Effects of Parapets on the Performance of Unglazed Solar Collectors (opens in a new tab)

  16. Piano Key Weir Head Discharge Relationships

    … sloped floors; raising the crest elevation via a parapet wall; fillets underneath the upstream overhangs; and the crest type. The physical model test matrix also included a PK weir configuration consistent with the Hydrocoop-recommended design. From the experimental results, the appropriateness of …

    utahstate Repository record for Piano Key Weir Head Discharge Relationships (opens in a new tab)

  17. Wind effects on sun tracking solar reflecting panels

    … led to the greatest pressure coefficients. A parapet was included to observe the wind effects of various positions. Additionally, pressure measurements were observed using a rounded edge installed on the lead panel edges. This notion was to assist in not only minimizing wind loads, but also in …

    nps Repository record for Wind effects on sun tracking solar reflecting panels (opens in a new tab)

Page 1 of 3