Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 214 for “"partial discharge"”.

  1. Radiometric partial discharge characterisation

    … are manifestations of this condition, called partial discharges (PD) and because of this, PD have been subject of an extensive study and investigation. PD identification relies on the intrinsic characteristics of the generated discharge. This thesis shows the behaviour of radiated discharge …

    strathclyde Repository record for Radiometric partial discharge characterisation (opens in a new tab)

  2. Partial discharge denoising for power cables

    Partial discharge (PD) diagnostics is considered a major and effective tool for the monitoring of insulating conditions of power cables. As such, a large amount of off-line or online PD measurements have been deployed in power cables during the past decades. However, challenges still exist in PD …

    strathclyde Repository record for Partial discharge denoising for power cables (opens in a new tab)

  3. Partial discharge monitoring of power transformers

    … an approach to the monitoring and measurement of partial </span>discharges within power transformers, including the classification and recognition of partial <span style='letter-spacing:-.25pt'>discharge signals in the both frequency and time domains from bushing tap points via </span><span …

    soton Download PDF for Partial discharge monitoring of power transformers (opens in a new tab)

  4. Partial discharge detection in cable systems

    … with the development of suitable methods for partial discharge (PD) detection, quantification and location within high voltage cable systems. Acoustic emission (AE) techniques are suitable for PD on-line monitoring. This approach is free from electrical interference. Application of acoustic …

    soton Download PDF for Partial discharge detection in cable systems (opens in a new tab)

  5. Modelling partial discharge in gaseous voids

    The measurement of partial discharge (PD) activity is a commonly used tool to quantify the health of electrical insulation material in high voltage plant. Models of PD activity have been developed in order to provide insight into the physical conditions present in PD systems. Modern PD models …

    soton Download PDF for Modelling partial discharge in gaseous voids (opens in a new tab)

  6. Partial discharge diagnostics in medium voltage cables

    … based maintenance strategies utilizing online partial discharge monitoring technologies. Partial discharges (PD) are the early symptoms of insulation degradation that can ultimately lead to complete breakdown of the insulation system.Presented in this thesis are novel contributions to the area …

    strathclyde Repository record for Partial discharge diagnostics in medium voltage cables (opens in a new tab)

  7. Partial discharge detection using distributed acoustic sensing

    … power to continue flowing for everyday life.<br/>Partial discharge is both a cause and important indicator of damage developing within electrical insulation. By monitoring partial discharge activity during an electrical asset's lifetime, an assessment of the insulation condition can be made and …

    soton Download PDF for Partial discharge detection using distributed acoustic sensing (opens in a new tab)

  8. Partial Discharge Testing and Detection under PWM Voltage

    <p>Partial Discharge detection and measurement is an important part of electric insulation design. However, in PWM (pulse width modulation) voltage source converter environments, the noise resulting from switching voltage (rise and fall times of tens of nanoseconds) makes detection and extraction …

    ut-knoxville Repository record for Partial Discharge Testing and Detection under PWM Voltage (opens in a new tab)

  9. Machine learning enhanced radio location of partial discharge

    Partial Discharge (PD) is a well-known indicator of plant failure in electricity facilities. A considerable proportion of assets including transformers, switch gears, and power lines are susceptible to PD due to incipient weakness of their dielectric components. These discharges may cause further …

    strathclyde Repository record for Machine learning enhanced radio location of partial discharge (opens in a new tab)

  10. Partial discharge source classification using pattern recognition algorithms

    … that are implemented for recognition of partial discharge patterns. For single PD source identification, twelve high performance, applicable feature extraction techniques on PRPD patterns are employed to extract features. In order to present a comprehensive classification system, 10 …

    manitoba Repository record for Partial discharge source classification using pattern recognition algorithms (opens in a new tab)

  11. Analysis of Partial Discharge Pulse Height Distribution Parameters

    Partial Discharges (PD) have been traditionally used to assess the state of any insulation system and its remnant life. In earlier work, Perspex (PMMA) samples with a needle plane gap have been aged with AC voltage. Their tree growth was monitored simultaneously by collecting PD at regular …

    odu Repository record for Analysis of Partial Discharge Pulse Height Distribution Parameters (opens in a new tab)

  12. Condition Monitoring of Power Equipment: Partial Discharge Analysis

    … condition monitoring of the power system is partial discharge(PD) measurements that provide a reliable and accurate insulation assessment. Partial discharge is becoming the most popular condition monitoring tool in every power utility with detection systems and AI-based data processing …

    tamu Repository record for Condition Monitoring of Power Equipment: Partial Discharge Analysis (opens in a new tab)

  13. Partial discharge detection during high voltage impulse tests

    A method for detecting and measuring partial discharges in air and oil immersed system under impulse voltage conditions has been developed. Previous techniques for measurement of partial discharges under impulse voltage conditions are briefly reviewed and an account given of the design, …

    unsw Repository record for Partial discharge detection during high voltage impulse tests (opens in a new tab)

  14. Investigation of partial discharge characteristics in piezoelectric ceramics

    … study investigates the applicability of using partial discharge (PD) test to evaluate the reliability of piezoelectric ceramics PZT. Preliminary PD and four-point flexure tests were conducted on a soft PZT ceramic and the influence of PD test on PZT samples is discussed. Weibull analysis of the …

    unsw Repository record for Investigation of partial discharge characteristics in piezoelectric ceramics (opens in a new tab)

  15. FDTD modelling of partial discharge in high voltage cables

    Partial discharge (PD) is recognized as an effective insulation diagnostic tool. PD measurement on high voltage (HV) cables is performed to evaluate the cable insulation conditions and high frequency current transformers (HFCTs) are widely used as the PD sensor. Detected PD signals can be subject …

    strathclyde Repository record for FDTD modelling of partial discharge in high voltage cables (opens in a new tab)

Page 1 of 11