Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"partial volume effects"”.

  1. Image Reconstruction for Spinal Cord PET/MRI

    … MR-derived attenuation maps. The impact of these effects and possible solutions were determined through a series of studies. A literature review established whether currently available physical phantoms were suitable for assessing the performance of PET/MR scanners. It was found that replicating …

    whiterose Download PDF for Image Reconstruction for Spinal Cord PET/MRI (opens in a new tab)

  2. Anatomically informed Bayesian inference for physiological imaging

    … all aspects of physiological imaging. Notably, volumetric techniques of limited spatial resolution struggle to image complex anatomies such as the cerebral cortex. One consequence of this is the partial volume effect, which introduces bias or confound into parameter measurements derived from …

    oxford Repository record for Anatomically informed Bayesian inference for physiological imaging (opens in a new tab)

  3. Computational Imaging Methods for Analysis of DaTScan SPECT Images

    … thus inherently accounts for the two sources of partial volume effects in SPECT images, namely limited system resolution and tissue-fraction effects. The proposed method was evaluated both qualitatively and quantitatively using highly realistic simulation studies. The method yielded accurate …

    wustl Repository record for Computational Imaging Methods for Analysis of DaTScan SPECT Images (opens in a new tab)

  4. Fabrication and Testing of a Microchannel Network Phantom for MRI Velocimetry

    … Slice thickness, order of image acquisition, partial volume effects, and acceleration effects are investigated, and show little effect on the measured flow rates. Examination of anatomical MR images show that the channels decreased in height during fabrication, which explains some of the …

    uiuc Repository record for Fabrication and Testing of a Microchannel Network Phantom for MRI Velocimetry (opens in a new tab)

  5. Novel statistical and geometric models for automated brain tissue labeling in magnetic resonance images

    … are often confounded by acquisition noise and partial-volume effects, developing an automatic, robust, and efficient segmentation is essential to the accurate quantification of disease severity. Existing methods often require subjective parameter tuning, anatomical atlases, and training, which …

    ubc Repository record for Novel statistical and geometric models for automated brain tissue labeling in magnetic resonance images (opens in a new tab) Download PDF for Novel statistical and geometric models for automated brain tissue labeling in magnetic resonance images (opens in a new tab)

  6. Segmentation of images with low-contrast edges

    … of low-contrast due to noise, occlusions, or partial volume effects, which are often unavoidable in practical applications. Incorporating prior shape information into the segmentation framework provides a more accurate and robust solution by constraining the evolving contour to resemble a …

    wvu Repository record for Segmentation of images with low-contrast edges (opens in a new tab)

  7. MRI Perfusion Measurements using Magnetic Susceptibility Effects: : Calibration Approaches and Contrast Agent Quantification

    … capillary level of the blood system. The blood volume flow rate in the capillaries is often referred to as perfusion, and knowledge about perfusion provides important information about the function and viability of the tissue, for example, in patients with ischaemic stroke, cancer, and …

    lund Repository record for MRI Perfusion Measurements using Magnetic Susceptibility Effects: : Calibration Approaches and Contrast Agent Quantification (opens in a new tab) Download PDF for MRI Perfusion Measurements using Magnetic Susceptibility Effects: : Calibration Approaches and Contrast Agent Quantification (opens in a new tab)

  8. Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging

    … suppress respiratory motion artifacts as well as partial volume effects (PVE) which represent another source of image degradation in PET/CT imaging. Computer simulations, phantom studies, as well as patient studies are conducted to test the performance of these proposed techniques and their …

    rice Repository record for Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging (opens in a new tab)

  9. Improving sensitivity and specificity in diffusion MRI group studies

    … coarse resolution of the data typically causes partial volume effects that bias the diffusion parameters and potentially mislead the interpretation of a group study outcome. We provide evidence that these effects can be addressed by constraining the diffusion model parameter space, which leads …

    oxford Repository record for Improving sensitivity and specificity in diffusion MRI group studies (opens in a new tab)

  10. Optimization of the Fair Technique for Specific Brain Region Perfusion Studies

    … inversion with a control for off-resonance effects) for quantifying cerebellum perfusion. The data indicate that FAIR ASST yields more robust CBF (cerebral blood flow) measurements. OPTIMAL FAIR (orthogonally-positioned tagging imaging method for arterial labeling of FAIR) was developed and …

    utswmed Repository record for Optimization of the Fair Technique for Specific Brain Region Perfusion Studies (opens in a new tab)

  11. Sequence Design and Contrast Optimization of Susceptibility Weighted Imaging

    … due to its sensitivity to blood products. Partial volume effects occur when a voxel contains both venous blood and brain parenchyma. We studied the apparent phase of a voxel as a function of imaging resolution and predict what the best imaging parameters for a specific clinical application …

    mcmaster Repository record for Sequence Design and Contrast Optimization of Susceptibility Weighted Imaging (opens in a new tab)

  12. Quantification of Oxygen Saturation of Venous Vessels Using Susceptibility Mapping

    … a different level of contrast depending on their partial volume effects; larger vessels show a bias toward a reduced susceptibility approaching 90% of the expected value. Also, streaking artifacts associated with high susceptibility structures such as veins are obvious in the reconstructed SM. To …

    mcmaster Repository record for Quantification of Oxygen Saturation of Venous Vessels Using Susceptibility Mapping (opens in a new tab)

  13. Quantitative Imaging With a Pinhole Cardiac SPECT CZT Camera

    … when correcting for attenuation, scatter and the partial volume effects. Clinical accuracy was assessed using 99mTc-tetrofosmin myocardial perfusion images obtained on the NM530c and comparing to DEW scatter-corrected images acquired on a conventional SPECT camera for the same patient. DEW-SC …

    carleton Repository record for Quantitative Imaging With a Pinhole Cardiac SPECT CZT Camera (opens in a new tab)

  14. Intercomparison of medical image segmentation algorithms

    … it suffers from artefacts including noise, partial volume effects and intensity inhomogeneities.Brain, being a very complicated structure, its precise segmentation is particularly necessary to delineate the borders of anatomically distinct regions and possible tumors. Many algorithms have …

    strathclyde Repository record for Intercomparison of medical image segmentation algorithms (opens in a new tab)

  15. Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung

    … of the lung parenchyma. Through‐plane motion, partial volume effects and ventilation artifacts were also reduced with a three-dimensional method for image registration. UTE-SENCEFUL was also able to quantify regional ventilation and presented similar results to previous studies.

    wurz-thes Repository record for Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung (opens in a new tab)

  16. In vivo MRI perfusion and structural correlates of pathology in frontotemporal lobar degeneration

    … However, interpretation of CBF is confounded by partial volume effects (PVEs) due to large voxels encompassing intracranial content with different perfusion levels and other confounds such as neurodegenerative atrophy. Partial volume correction (PVC), data cleaning, and other techniques attempt …

    penn Repository record for In vivo MRI perfusion and structural correlates of pathology in frontotemporal lobar degeneration (opens in a new tab)

  17. PET/MR imaging of hypoxic atherosclerotic plaque using 64Cu-ATSM

    … plaque and evaluated the relative effects of diet and genetics on hypoxia progression in atherosclerotic plaque in a genetically-altered mouse model. We then fully validated the feasibility of using 64Cu-ATSM to image the extent of hypoxia in a rabbit model with atherosclerotic-like …

    wustl Repository record for PET/MR imaging of hypoxic atherosclerotic plaque using 64Cu-ATSM (opens in a new tab)

  18. Morphometric analysis of brain structures in MRI

    … of bias fields, boundary detection by modelling partial volume effects (PVE), and a combined statistical and geometrical segmentation method. Most importantly, it also allows for the computation of confidence bounds in the location of the object being segmented by bounding PVE voxels. Bounds …

    oxford Repository record for Morphometric analysis of brain structures in MRI (opens in a new tab)

  19. Quantification of cerebral vascular hemodynamics using MRI

    … perfusion using ASL MRI is not only limited by partial volume effects, due to the relatively low resolution of the ASL data, but also affected by confounding factors including arterial transit time (ATT) and blood flow velocity. This thesis investigates the sensitivity of partial volume …

    oxford Repository record for Quantification of cerebral vascular hemodynamics using MRI (opens in a new tab)

  20. MRI-informed and machine-learning assisted PET image reconstruction

    … spatial resolution of the PET system leads to partial volume effects (PVEs), which introduce bias in regional quantification. The recent advent of clinically available simultaneous PET-MR scanners enables the simultaneous acquisition of complementary information within a clinically practical …

    kings Repository record for MRI-informed and machine-learning assisted PET image reconstruction (opens in a new tab) Download PDF for MRI-informed and machine-learning assisted PET image reconstruction (opens in a new tab)

Page 1 of 2