Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 29 for “"partially grouted"”.
-
GROUT DESIGN FOR PARTIALLY GROUTED RIPRAP
… In addition to basic, loose riprap, partially grouted riprap (PGR) is also an option when selecting a countermeasure. PGR is relatively new in the United States, but has been used widely in Europe to prevent scour or erosion of the bed, banks, shoreline, and at piers and abutments. …
-
Diagonal Shear Of Partially Grouted Concrete Masonry Panels
Masonry shear walls are the main structural elements that resist in-plane lateral loads applied to a masonry building. The current Canadian Code assumes the shear resistance of a masonry wall to be the sum of two components: the shear resistance of the masonry and the shear resistance of horizontal …
-
On The Shear Strength Of Partially Grouted Concrete Masonry
… on the shear behaviour of wide-spaced reinforced partially grouted (WRPG) concrete masonry walls. Twenty one shear walls were constructed with reduced-scale concrete masonry units. The experimental program consisted of eight groups of tests, with two or three identical specimens in each group. The …
-
Behaviour of Partially Grouted Nominally Reinforced Masonry Shear Walls under Dynamic Loading
… The code does not provide any provisions for partially grouted shear walls in regions with moderate seismic demand. The experimental program described in the thesis focuses on the dynamic performance of partially grouted nominally reinforced concrete masonry shear walls having less steel and …
-
Behaviour of Partially Grouted Reinforced Masonry Shear Walls under Cyclic Reversed Loading
… In this research program, the performance of partially grouted reinforced masonry (PG-RM) shear walls, having larger reinforcement spacing than specified as minimum seismic requirements, has been evaluated to help in future efforts to offer some relief from the code's limitation.</p> <p>As the …
-
Strut-and-Tie Modeling of Multistory, Partially-Grouted, Concrete Masonry Shear Walls with Openings
… a practice known as partial-grouting. Partially-grouted masonry responds differently and in a more complex matter to lateral loads as compared to fully-grouted masonry. The response is made even more complex by wall discontinuities in the form of openings. The main objective of this …
-
Parametric Study on Multi-Story, Partially Grouted, Perforated, Masonry Shear Walls by Finite Element Analysis
… to determine their influence on multi-story, partially grouted, perforated (openings), masonry shear walls using a finite element software FormWorks. The parameters studied were: the strength of grouted masonry prisms f'm,grouted; the strength of un-grouted (hollow) masonry prisms …
-
In-plane Cyclic Response of Flexural-Dominated Partially Grouted Reinforced Masonry Shear Walls with Boundary Elements
… and grout. This complexity is heightened in partially grouted (PG) walls, where stiffness discontinuities occur at interfaces between grouted and ungrouted cells. The scarcity of experimental data on the materials’ properties has further complicated the development of accurate analytical …
-
In-plane Cyclic Response of Slender Rectangular and Flanged Partially Grouted Reinforced Masonry Shear Walls Failing in Flexure
Partially grouted reinforced masonry shear walls (PG-RMSWs) have emerged as an efficient and economic seismic force-resisting system (SFRS) in North America. In PG-RMSWs, grout is only placed in cells with vertical reinforcement and horizontally reinforced bond beams. Despite the economic benefits …
-
Modelling In-plane Shear in Partially Reinforced Concrete Masonry
… cracks in unreinforced concrete masonry and partially grouted/reinforced concrete masonry. Some key parameters (such as boundary and loading conditions, axial stress, and wall aspect ratio) were examined in the research. Interaction between axial stress and aspect ratio has been noticed. …
-
Investigation on the Shear Strength and Capacity of Concrete Block Masonry
Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design …
-
Shear Strength Prediction Methods for Grouted Masonry Shear Walls
… and show a higher degree of variation for partially-grouted walls. The first approach modifies the existing MSJC equation to account for the differences in nominal strength and uncertainty between fully- and partially-grouted walls. The second approach develops a new shear strength equation …
-
Seismic performance, analysis, and design of hybrid concrete-masonry
… consist of a reinforced concrete frame with partially grouted and reinforced infill masonry walls. The infill walls are typically connected to the RC frame with cast-in-place dowel reinforcement along one or more edges of the wall. There is limited guidance in masonry codes to design these …
-
The influence of vertical reinforcement and lateral confinement on the axial capacity of masonry block walls
… confinement on the axial capacity of short partially grouted concrete masonry walls built in running bond. In order to better understand the structural behaviour of both confined and unconfined concrete masonry, it is important to have some knowledge of the load-displacement behaviour, …
-
In-Plane Shear Investigation on Masonry Walls
… and finite element software. Out of 35 fully grouted walls from the database and 13 finite element walls constructed with a macro-model approach, strength calculations produced an average [experimental shear strength/predicted shear strength] of 1.63 with a coefficient of variation [COV] of …
-
Out-of-plane behaviour of concrete block walls with unbonded reinforcement
… alternatives to unreinforced and conventionally grouted and reinforced walls. The strength and serviceability of these walls was evaluated. All walls in this program were two and a half blocks wide and 14 courses tall and were built in running bond using standard 200 mm concrete blocks. Six …
-
In-Plane Cyclic Testing of Reinforced Concrete Masonry Walls to Assess the Effect of Varying Reinforcement Anchorage and Boundary Conditions
… to observe the quasi-static performance of partially grouted reinforced masonry walls with variable parameters. The experimental program described in this dissertation is a portion of the larger experimental program and the focus here is on the anchorage conditions of the bond beam …
-
In-Plane Cyclic Shear Performance of Interlocking Compressed Earth Block Walls
… hollow units, which can be reinforced and grouted after they are laid. Although significant research has been undertaken to optimize the material properties of CEBs, little has been done to investigate the performance of structural systems currently being built using this technology. Test …
-
FINITE ELEMENT ANALYSES OF PARTIALLY REINFORCED MASONRY SHEAR WALLS
Partially reinforced shear walls are used in regions of relatively low seismic risk. Nevertheless, these structures should be capable to resist some lateral motion. The purpose of this paper is to examine the behavior of in-plane cyclic load tests of typical partially-grouted masonry shear walls …
-
Experimental evaluation and modeling of concrete masonry unit walls
… recorded until failure. The walls were fully- or partially- grouted and constructed with various materials. An analytical model was developed to predict the static resistance function of the CMU walls. Depending on wall type and desired blast response the analytical model predictions were within …
Page 1 of 2