Statistical analysis and reliability applications of partially restrained steel connections
… to consider the partial restraint in a steel connection. A design with a partially restrained connection reduces the design moment, therefore reducing member sizes. A generated nonlinear equation was fitted to available experimental data on six different types of connections. The connections …
-
A Finite element model for partially restrained steel beam to column connections
… it is customary to assume the beam to column connections as either fully rigid which means that all moments are transferred from beam to column with negligible rotation or ideally pinned that resists negligible moment. This assumption is reasonable for some types of connections. However when …
-
STRENGTH DETERMINATION OF HEAVY CLIP-ANGLE CONNECTION COMPONENTS
… through the early 1990s fully welded beam-column connections were considered to be the connection of choice in moment resisting structural frames, especially in seismic regions. During the Northridge and Kobe earthquakes, however, fully welded connections suffered significant damage. Although …
-
Innovative Self-Centering Connection for CCFT Composite Columns