Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 39 for “"partially-restrained"”.

  1. Feasibility Study of Partially Restrained Connections

    In recent years the idea of using partially restrained connections in building structures has become more practical and economical. Partially restrained connections resist moment and also allow rotation, therefore distributing the moments and stresses more evenly throughout the element. Combining …

    vt Repository record for Feasibility Study of Partially Restrained Connections (opens in a new tab)

  2. Design of frames with partially restrained connections.

    The load and resistance factor design (AISC-LRFD) specification allows the designer to consider the partial restraint (PR) in a steel connection. The success of efforts to include connection effects in the design will depend greatly on the development of reliable and practical analytical methods …

    arizona-thes Repository record for Design of frames with partially restrained connections. (opens in a new tab)

  3. Prototype expert system in partially restrained steel connection design

    <p>The suitability of an expert system to design steel connections is investigated. The design is based on the American Institute of Steel Construction's Load and Resistance Factor Design manual. The prototype expert system designs welded seated beam connections and standard bolted framed …

    utk-theses Repository record for Prototype expert system in partially restrained steel connection design (opens in a new tab)

  4. Reliability and effect of partially restrained wood shear walls

    ABSTRACT RELIABILITY AND EFFECT OF PARTIALLY RESTRAINED WOOD SHEAR WALLS by JOHN J. GRUBER MARCH 2012 Advisor: Dr. Gongkang Fu Major: Civil Engineering Degree: Doctor or Philosophy The prescriptive design of the most widely used residential building code in the United States, the IRC, allows the …

    wayne-thes Repository record for Reliability and effect of partially restrained wood shear walls (opens in a new tab)

  5. Evaluation of Overstrength Factors for Partially-Restrained Steel Frames

    … simulate earthquake loading. Overstrength of partially-restrained non-composite steel frames has not been thoroughly studied within the context of seismic design. Therefore, seismic codes do not contain response modification factors for the design of these frames. Overstrength can be defined …

    marquette Repository record for Evaluation of Overstrength Factors for Partially-Restrained Steel Frames (opens in a new tab)

  6. Behavior and modeling of partially restrained beam-girder connections

    Beams in a typical steel framed floor design are assumed to have pinned supports for purposes of design. In reality, the connections between the beams and girders in a steel framed floor system are not pinned. The design bending moments and deflections of the attached beam could be reduced if the …

    vt Repository record for Behavior and modeling of partially restrained beam-girder connections (opens in a new tab)

  7. Statistical analysis and reliability applications of partially restrained steel connections

    … restraint in a steel connection. A design with a partially restrained connection reduces the design moment, therefore reducing member sizes. A generated nonlinear equation was fitted to available experimental data on six different types of connections. The connections analyzed were single web …

    ut-knoxville Repository record for Statistical analysis and reliability applications of partially restrained steel connections (opens in a new tab)

  8. Post-buckled performance of partially restrained and intermediately supported steel angles

    The post-buckled performance of cross-braced single angles was experimentally determined. The results of this study will be used by the Bonneville Power Administration for the analysis of member performance in transmission towers.

    portland-state Repository record for Post-buckled performance of partially restrained and intermediately supported steel angles (opens in a new tab)

  9. Seismic Performance of Dual Systems Composed of Fully and Partially Restrained Frames

    Fully-restrained connection failures resulting from the 1994 Northridge earthquake caused increased interest in the use of partially-restrained connections in seismic resistant design of steel structures. When a building structure is subjected to ground motion, its base tends to move with the …

    marquette Repository record for Seismic Performance of Dual Systems Composed of Fully and Partially Restrained Frames (opens in a new tab)

  10. Inelastic behavior of partially restrained steel frames using parallel processing and supercomputers

    … However, the advanced inelastic analysis of partially restrained planar steel frames has been limited to small scale structures. In addition, analytic models for structural members commonly utilize concentrated plasticity and interaction surfaces to simulate inelastic behavior of the members …

    marquette Repository record for Inelastic behavior of partially restrained steel frames using parallel processing and supercomputers (opens in a new tab)

  11. Second-Order Elastic Analysis of Gable Frames Utilizing Tapered Members and Partially Restrained Connections

    Past research and questions raised by practicing engineers have indicated a need to look further into the structural behavior of gable frame buildings, primarily second-order bending moments and lateral sway. Limited research has been conducted in the area of gable frames, of which, the combined …

    marquette Repository record for Second-Order Elastic Analysis of Gable Frames Utilizing Tapered Members and Partially Restrained Connections (opens in a new tab)

  12. Design of Partially Restrained Steel Frames Using Advanced Analysis and An Object-Oriented Evolutionary Algorithm

    … of an optimization algorithm. to design fully-restrained (FR) and partially-restrained (PR) steel frames. Upon review of the optimization techniques available in the literature, an evolutionary algorithm (EA) was selected to stochastically guide the algorithm through the solution space of …

    marquette Repository record for Design of Partially Restrained Steel Frames Using Advanced Analysis and An Object-Oriented Evolutionary Algorithm (opens in a new tab)

  13. Evaluation of the Yield Point Spectra Technique for Performance-Based Design of Partially-Restrained Steel Frames

    … of the yield point spectra method for fully restrained (FR) structural steel buildings. However, the yield point spectra method contains several assumptions that require verification for PR (semi-rigid) steel frameworks. The objective of this thesis is to perform a detailed evaluation of the …

    marquette Repository record for Evaluation of the Yield Point Spectra Technique for Performance-Based Design of Partially-Restrained Steel Frames (opens in a new tab)

  14. Inelastic seismic response and ductility evaluation of steel frames with fully, partially restrained and composite connections

    … that beam-to-column connection are either fully restrained (FR) or perfectly pinned (PP) connections. However, almost all steel connections used in practice are essentially partially restrained (PR) connections with different rigidities. The effect of PR and composite connections on the nonlinear …

    arizona-thes Repository record for Inelastic seismic response and ductility evaluation of steel frames with fully, partially restrained and composite connections (opens in a new tab)

  15. Stochastic finite element method for the reliability analysis of nonlinear frames with PR connections.

    … Nonlinearities due to geometry, material and partially restrained connections are considered in the procedure. A computational model based on the Richard model is developed to address the uncertain properties of partially restrained connections. The material properties, geometric properties, …

    arizona-thes Repository record for Stochastic finite element method for the reliability analysis of nonlinear frames with PR connections. (opens in a new tab)

  16. Structural behaviour of cold-formed steel purlin-sheeting systems under uplift loading

    … describe the bending and twisting behaviour of partially restrained zed- and channel-section purlins when subjected to uplift loading. Formulae used to calculate the bending stresses of the roof purlins are derived by using the classical bending theory of thin-walled beams. Detailed comparisons …

    birmingham Download PDF for Structural behaviour of cold-formed steel purlin-sheeting systems under uplift loading (opens in a new tab)

Page 1 of 2