  1. Development of a Thin CVD Diamond Detector as a Transmission-Type Alpha Particle Counter at McMaster University Biological Microbeam Facility

    … and subcellular targets with individual charged particles. This study describes the simulation and fabrication of a super-thin single crystalline chemical vapor deposited diamond membrane, intended to act as a radiation detector and a vacuum window at the McMaster University biological microbeam …

    mcmaster Repository record for Development of a Thin CVD Diamond Detector as a Transmission-Type Alpha Particle Counter at McMaster University Biological Microbeam Facility (opens in a new tab)

  2. An optical particle counter for the regular application onboard a passenger aircraft: instrument modification, characterization and results from the first year of operation

    To understand the contribution of aerosol particles to radiative forcing and heterogeneous chemical processes in the upper troposphere and lowermost stratosphere (UT/LMS), the knowledge of the particle size distribution is mandatory. Unfortunately, measurements in the UT/LMS are costly. Research …

    qucosa-diss

  3. A Hot-Wire Anemometer for Particle Counters

    … to be promising. One such device is the optical particle counter. The particle counter functions by having laminar airflow with constant velocity traverse the path of a laser beam within an airflow channel. This thesis presents the design and integration of a hot-wire anemometer into the flow …

    boise Repository record for A Hot-Wire Anemometer for Particle Counters (opens in a new tab)

  4. A Lab-based Study for the Generation and Characterization of Particle Emission from Composite Materials Containing Carbon Nanotubes

    … to measure and characterize the emission of particles during the sanding of composite materials containing carbon nanotubes (CNTs). The experimental setup consisted of a sand-blasting cabinet with HEPA-filtered air intakes. An electrical motor outside the cabinet was connected to a pulley …

    wvu Repository record for A Lab-based Study for the Generation and Characterization of Particle Emission from Composite Materials Containing Carbon Nanotubes (opens in a new tab)

  5. Use of a convective emission chamber to study particle resuspension

    … C),$ and relative humidity (30-80%). Particle resuspension rates were measured with a laser based optical particle counter for various combinations of environmental conditions with and without the presence of mechanical disturbance of the source. The resuspension rates for the various …

    uiuc Repository record for Use of a convective emission chamber to study particle resuspension (opens in a new tab)

  6. Occupational Exposure To Cooking Emissions And Evaluation Of Ventilation System In Restaurant Kitchens

    … potential exposure to aldehydes and respirable particles among restaurant kitchen workers and to examine the ventilation performance of the kitchen exhaust hoods. Methods: There were three restaurants recruited for this study and they cooked seafood/poultry (Restaurant 1), farm style foods …

    uab Repository record for Occupational Exposure To Cooking Emissions And Evaluation Of Ventilation System In Restaurant Kitchens (opens in a new tab)

  7. An evaluation of a Coulter Counter method for the determination of primary productivity, and an assessment of seasonal phytoplankton biomass and species composition at West Blue Lake, Manitoba

    … primary production by use of an electronic particle counter (Coulter Counter). In order to convert productivity values determined as volume by this method into more meaningful carbon values, it was necessary to establish a relationship between carbon and volume. Although the method was found …

    manitoba Repository record for An evaluation of a Coulter Counter method for the determination of primary productivity, and an assessment of seasonal phytoplankton biomass and species composition at West Blue Lake, Manitoba (opens in a new tab)

  8. Particle behavior in solid propellant rocket motors and plumes

    The particle size distribution inside the combustion chamber and the changes that occurred across the exhaust nozzle were measured in a subscale solid propellant rocket motor with a 2% aluminized end-burning propellant grain and a highly underexpanded nozzle. A combination of diagnostic techniques …

    nps Repository record for Particle behavior in solid propellant rocket motors and plumes (opens in a new tab)

  9. Zooplankton Grazing in Kaneohe Bay, Hawaii

    … The concentration by volume of suspended particles, as determined with an electronic particle counter, was used as the estimate of food concentration. The relationship between grazing rate per animal and concentration of particulate food conformed closely to a hyperbolic model widely used …

    hawaii Repository record for Zooplankton Grazing in Kaneohe Bay, Hawaii (opens in a new tab)

  10. Resolving bacteria with the coulter counter

    … counting and sizing of bacteria with the Coulter Counter and to evaluate orifices which were prepared in this laboratory. Size distributions of Pasteurella multocida and Proteus vulgaris were obtained with the electronic particle counter. These distributions appeared to follow the normal …

    vt Repository record for Resolving bacteria with the coulter counter (opens in a new tab)

  11. Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Indoor Exposure

    … health and public health education. Optical particle counters are of interest in this regard. However, these lower-cost sensors are generally expected to lack the quality paid for in higher-cost sensors, thus leaving the question of their efficacy, especially at different concentrations and …

    ecu Repository record for Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Indoor Exposure (opens in a new tab)

  12. Testing of a passive sediment trap for river environments

    … distributions were found using a Spectrex Laser particle counter. Data collected from the North Saskatchewan River assisted in the analysis of trap performance. Sediment capture was found to scale with the cross sectional area of the sediment trap and the integration time. Results from the …

    sask Repository record for Testing of a passive sediment trap for river environments (opens in a new tab)

  13. Characterisation of airborne dust in a South African opencast iron ore mine : a pilot study

    … exposure and health, especially for ultrafine particles (UFP). It is therefore imperative to characterise airborne dust containing micrometer and UFP size particles originating from specific areas to determine if there are physical- and chemical characteristics that may or may not have an …

    nwu-za Repository record for Characterisation of airborne dust in a South African opencast iron ore mine : a pilot study (opens in a new tab)

  14. Monitoring and Measurement of Electronic Nicotine Delivery Systems Using Improved Detection Sensor and Novel Vaping Machine

    … of VM-FRIENDS were combined with a condensation particle counter to enable characterization of vape aerosol production under controlled conditions. This work facilitates further ENDS research by enabling deployment of the FRIENDS sensor in real-world studies and offering VM-FRIENDS as a …

    alabama Repository record for Monitoring and Measurement of Electronic Nicotine Delivery Systems Using Improved Detection Sensor and Novel Vaping Machine (opens in a new tab)

  15. A STUDY ON THE IMPACT OF FILTRATION ON SOME KNOWN AIR CONTAMINANTS

    … distribution was determined using an optical particle counter while the Andersen single stage sampler was used to assay bioaerosols. As for sampling of TVOCs, a multi-Gas monitor and multi-point Sampler & Doser were used. The effectiveness of the various filtration strategies were compared …

    nus Repository record for A STUDY ON THE IMPACT OF FILTRATION ON SOME KNOWN AIR CONTAMINANTS (opens in a new tab) Download file for A STUDY ON THE IMPACT OF FILTRATION ON SOME KNOWN AIR CONTAMINANTS (opens in a new tab)

  16. Effects of Optical Configuration and Sampling Efficiency on the Response of Low-Cost Optical Particle Counters

    … and particulate matter (PM). A Low-cost Optical Particle Counter (OPC), costing less than 50 USD, is an example of such technologies. Currently, OPCs are widely used to measure the concentration of particle matter in ambient air. While these low-cost air quality sensors are widely available, the …

    byu Repository record for Effects of Optical Configuration and Sampling Efficiency on the Response of Low-Cost Optical Particle Counters (opens in a new tab) Download PDF for Effects of Optical Configuration and Sampling Efficiency on the Response of Low-Cost Optical Particle Counters (opens in a new tab)

  17. Assessment of Airborne Microfiber Pollution and Worker Exposure in the Garment Industry

    … aerosol instruments, including the TSI AeroTrak particle counter and PDR-1200 particulate monitor. In addition, questionnaires were administered to 30 workers to collect demographic, occupational, and health-related information. Results showed clear spatial and temporal differences in particulate …

    jhu Repository record for Assessment of Airborne Microfiber Pollution and Worker Exposure in the Garment Industry (opens in a new tab)