Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"particulate matter measurement"”
-
Particulate matter measurement in a shock tube facility under engine-relevant conditions
This study develops and demonstrates a particulate matter (PM) measurement system in a shock tube facility, in order to investigate correlations between PM emissions and combustion parameters. The resultant method was applied to premixed and non-premixed experiments using several diesel-alternative …
-
Development of novel methodologies for utilising low-cost sensors for ambient Particulate Matter measurement
… increasing concern about the impact of ambient Particulate Matter (PM) exposure on human health. Existing ambient air quality monitoring networks, because of their sparseness, are not able to capture the spatial-temporal variation of ambient PM concentration. Recent studies have shown that …
-
Observations of the tapered element oscillating microbalance as compared to a gravimetric method for particulate matter measurement
… to see if the concentration of the particular matter (PM) flowing through the TEOM has an effect on accuracy. The flow rate was varied to find the optimal setting using the Federal Test Procedure (FTP) run on a 1992 Detroit Diesel Series 60 engine. The comparison to the gravimetric experiment …
-
In-line, Real-time Particulate Matter Sensors for OBD and Exhaust After-treatment System Control Applications
… for continuously monitoring and diagnosing the particulate matter removal efficiency of modern exhaust gas after-treatment systems. Extensive literature survey suggested a sensor operating on the diffusion-charging principle being optimally suited for particle measurements due to their …
-
Multiplexed microfluidic sensor for the cell, cell secretome, and particulate matter detection
… detection of the cell, cell secretome, and particulate matter and have broad applications in disease diagnosis, environmental monitoring, stem cell research and drug screening. Accurate identification and counting of cells can dramatically improve early disease diagnosis, facilitate mass …
-
Effects of Optical Configuration and Sampling Efficiency on the Response of Low-Cost Optical Particle Counters
… individual exposure to gaseous pollutants and particulate matter (PM). A Low-cost Optical Particle Counter (OPC), costing less than 50 USD, is an example of such technologies. Currently, OPCs are widely used to measure the concentration of particle matter in ambient air. While these low-cost …
-
A study of laser-induced incandescence under high vacuum conditions
… pulsed laser beam encounters graphitic particulate matter particles like soot or carbon black. The particles absorb laser energy from the beam and see an increase in their internal energy, resulting in an increase of temperature. At the same time, the particles loose energy through heat …
-
A highly efficient microfluidic particles removal device with staggered herringbone micromixers
<p>Particulate matter (PM) has caused a significant challenge to our daily life. The effect included severe air pollution, the health threat, and climate change by absorbing and scattering solar radiation. Due to the mechanism of the traditional filter, they cannot achieve the high removal …
-
Global sources and impacts of absorptive components in atmospheric organic aerosols
… them difficult to identify and quantify. Due to measurement limitations, the sources of the absorptive components of OA are not well understood. This thesis aims to quantify the global sources of the absorptive components in atmospheric OA to better assess their climate effects.</p> <p>Biomass …